Literature DB >> 10728971

Evidence of chemical bonding at biomaterial-hard tissue interfaces.

Y Yoshida1, B Van Meerbeek, Y Nakayama, J Snauwaert, L Hellemans, P Lambrechts, G Vanherle, K Wakasa.   

Abstract

For many years, glass-polyalkenoate cements have been described as possessing the unique properties of self-adherence to human hard tissues, such as bones or teeth. However, direct experimental evidence to prove the existence of chemical bonding has not been advanced. X-ray Photoelectron Spectroscopy (XPS) was used to analyze the chemical interaction of a synthesized polyalkenoic acid with enamel and synthetic hydroxyapatite. For both enamel and hydroxyapatite, the peak representing the carboxyl groups of the polyalkenoic acid was detected to have significantly shifted to a lower binding energy. De-convolution of this shifted peak disclosed two components with a peak representing unreacted carboxyl groups and a peak suggesting chemical bonding to hydroxyapatite. On average, 67.5% of the carboxyl groups of the polyalkenoic acid were measured to have bonded to hydroxyapatite. XPS of hydroxyapatite also disclosed its surface to be enriched in calcium and decreased in phosphorus, indicating that phosphorus was extracted at a relatively higher rate than calcium. Analysis of these data supports the mechanism in which carboxylic groups replace phosphate ions (PO4(3-)) of the substrate and make ionic bonds with calcium ions of hydroxyapatite. It is concluded that an ultrathin layer of a polyalkenoic acid can be prepared on a hydroxyapatite-based substrate by careful removal of non-bonded molecules. With this specimen-processing method, XPS not only provided direct evidence of chemical bonding, but also enabled us to quantify the percentages of functional groups of the polyalkenoic acids that bonded to calcium of hydroxyapatite.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10728971     DOI: 10.1177/00220345000790020301

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  50 in total

Review 1.  Atraumatic restorative treatment versus amalgam restoration longevity: a systematic review.

Authors:  Steffen Mickenautsch; Veerasamy Yengopal; Avijit Banerjee
Journal:  Clin Oral Investig       Date:  2009-08-18       Impact factor: 3.573

2.  Clinical effectiveness of a one-step self-etch adhesive in non-carious cervical lesions at 2 years.

Authors:  R Banu Ermis; Kirsten L Van Landuyt; Marcio Vivan Cardoso; Jan De Munck; Bart Van Meerbeek; Marleen Peumans
Journal:  Clin Oral Investig       Date:  2011-05-21       Impact factor: 3.573

3.  A Mechanistic study of Plasma Treatment Effects on Demineralized Dentin Surfaces for Improved Adhesive/Dentin Interface Bonding.

Authors:  Xiaoqing Dong; Meng Chen; Yong Wang; Qingsong Yu
Journal:  Clin Plasma Med       Date:  2014-07-01

4.  Evaluation of mechanical and adhesion properties of glass ionomer cement incorporating nano-sized hydroxyapatite particles.

Authors:  Mohit Kheur; Nidhi Kantharia; Tabrez Iakha; Supriya Kheur; Nadin Al-Haj Husain; Mutlu Özcan
Journal:  Odontology       Date:  2019-04-26       Impact factor: 2.634

5.  One-year clinical evaluation of bulk-fill flowable vs. regular nanofilled composite in non-carious cervical lesions.

Authors:  Gabriela D Canali; Sergio A Ignácio; Rodrigo N Rached; Evelise M Souza
Journal:  Clin Oral Investig       Date:  2018-06-12       Impact factor: 3.573

Review 6.  Dissolution mechanism of calcium apatites in acids: A review of literature.

Authors:  Sergey V Dorozhkin
Journal:  World J Methodol       Date:  2012-02-26

7.  Comparison of laser- and bur-prepared class I cavities restored with two different low-shrinkage composite resins: a randomized, controlled 60-month clinical trial.

Authors:  O Z Fatma Dilsad; Esra Ergin; Nuray Attar; Sevil Gurgan
Journal:  Clin Oral Investig       Date:  2019-05-17       Impact factor: 3.573

8.  Five-year clinical performance of a silorane- vs a methacrylate-based composite combined with two different adhesive approaches.

Authors:  Bruno Baracco; M Victoria Fuentes; Laura Ceballos
Journal:  Clin Oral Investig       Date:  2015-09-21       Impact factor: 3.573

9.  Comparison of failure mechanisms for cements used in skeletal luting applications.

Authors:  O Clarkin; D Boyd; M R Towler
Journal:  J Mater Sci Mater Med       Date:  2009-03-13       Impact factor: 3.896

10.  Improvement of enamel bond strengths for conventional and resin-modified glass ionomers: acid-etching vs. conditioning.

Authors:  Ling Zhang; Tian Tang; Zhen-liang Zhang; Bing Liang; Xiao-miao Wang; Bai-ping Fu
Journal:  J Zhejiang Univ Sci B       Date:  2013-11       Impact factor: 3.066

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.