Literature DB >> 15132455

A comparison of shear bond strength and debonding characteristics of conventional, moisture-insensitive, and self-etching primers in vitro.

Rangaswamy Rajagopal1, Sridevi Padmanabhan, Janakirama Gnanamani.   

Abstract

Bond failure is often attributed to moisture contamination. To overcome this commonly encountered problem, materials have been developed that are hydrophilic and that are believed to offer better bond strength in moisture-contaminated environment. Shear bond strength was compared among three materials: conventional Transbond XT primer (3M Unitek), moisture-insensitive primer (MIP, 3M Unitek), and self-etch primer (Transbond plus, 3M Unitek). Bond strength was tested under laboratory conditions with brackets bonded on both dry enamel and enamel contaminated with natural saliva. Self-etch primer showed maximum bond strength under both dry and wet conditions. Conventional primer was comparable with the former under dry conditions but did not offer clinically adequate bond strength in cases of moisture contamination. Both MIP and self-etch primer showed adequate bond strength superior to that of conventional primer in case of moisture contamination. All primers showed typical debonding characteristics of separation at the bracket-adhesive interface or within the adhesive itself, with the exception of the conventional primer used with moisture-contaminated enamel.

Mesh:

Substances:

Year:  2004        PMID: 15132455     DOI: 10.1043/0003-3219(2004)074<0264:ACOSBS>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  25 in total

1.  SBS vs Inhouse Recycling Methods-An Invitro Evaluation.

Authors:  Supradeep Kumar Kamisetty; Jaya Krishanan Verma; Shanta Sundari; Shyamala Chandrasekhar; Aravind Kumar
Journal:  J Clin Diagn Res       Date:  2015-09-01

2.  Shear bond strength of orthodontic brackets bonded with a new self-adhering flowable resin composite.

Authors:  Cecilia Goracci; Mariam Margvelashvili; Agostino Giovannetti; Alessandro Vichi; Marco Ferrari
Journal:  Clin Oral Investig       Date:  2012-04-27       Impact factor: 3.573

3.  Effects of moisture conditions of dental enamel surface on bond strength of brackets bonded with moisture-insensitive primer adhesive system.

Authors:  Toshiya Endo; Rieko Ozoe; Sugako Sanpei; Koichi Shinkai; Yoshiroh Katoh; Shohachi Shimooka
Journal:  Odontology       Date:  2008-07-27       Impact factor: 2.634

4.  Influence of Adhesives and Methods of Enamel Pretreatment on the Shear Bond Strength of Orthodontic Brackets.

Authors:  Sanja Jurišić; Gordan Jurišić; Hrvoje Jurić
Journal:  Acta Stomatol Croat       Date:  2015-12

5.  Blood contamination effect on shear bond strength of an orthodontic hydrophilic resin.

Authors:  Taís de Morais Alves da Cunha; Bruna Ariela Behrens; Denise Nascimento; Luciana Borges Retamoso; Luís Filipe Siu Lon; Orlando Tanaka; Odilon Guariza Filho
Journal:  J Appl Oral Sci       Date:  2012-02       Impact factor: 2.698

6.  Invitro Study of the Effect of Different Samples of Water Used for Washing the Etchant on Bracket Bond Strength.

Authors:  Sandesh Phaphe; Chanamallappa Ganiger; Yusuf Ahammed; Pratap Mane
Journal:  J Clin Diagn Res       Date:  2015-10-01

7.  Influence of orthodontic adhesives and clean-up procedures on the stain susceptibility of enamel after debonding.

Authors:  Hyun-Jin Joo; Yong-Keun Lee; Dong-Yul Lee; Yae-Jin Kim; Yong-Kyu Lim
Journal:  Angle Orthod       Date:  2011-03       Impact factor: 2.079

8.  Shear bond strength of brackets bonded with hydrophilic and hydrophobic bond systems under contamination.

Authors:  Bianca Mota Santos; Matheus Melo Pithon; Antonio Carlos de Oliveira Ruellas; Eduardo Franzotti Sant'Anna
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

9.  Clinical bond failure rates of adhesive precoated self-ligating brackets using a self-etching primer.

Authors:  Mete Ozer; Mehmet Bayram; Cagri Dincyurek; Fuat Tokalak
Journal:  Angle Orthod       Date:  2013-07-02       Impact factor: 2.079

10.  Comparison of Shear Bond Strength of Orthodontic Brackets Bonded to Enamel Prepared By Er:YAG Laser and Conventional Acid-Etching.

Authors:  M H Hosseini; F Namvar; J Chalipa; K Saber; N Chiniforush; S Sarmadi; A H Mirhashemi
Journal:  J Dent (Tehran)       Date:  2012-03-31