Literature DB >> 12750674

The effect of blood contamination on the shear bond strength of orthodontic brackets with the use of a new self-etch primer.

Charuphan Oonsombat1, Samir E Bishara, Raed Ajlouni.   

Abstract

The success of bonding brackets to enamel with resin bonding systems is negatively affected by contamination with oral fluids such as blood and saliva. The new self-etch primer systems combine conditioning and priming agents into a single application, making the procedure more cost-effective. The purpose of this study was to assess the effect of blood contamination on the shear bond strength of orthodontic brackets with a new self-etch primer. The brackets (precoated brackets APC II, 3M Unitek, Monrovia, Calif) were bonded to 52 extracted human molars according to 1 of 4 protocols. Group I: A self-etch acidic primer, Angel I (3M/ESPE, St. Paul, Minn), was placed on the enamel for 15 seconds, gently dried with air, and light cured for 10 seconds. Brackets were bonded and light cured for 20 seconds. Group II: The enamel surface was contaminated with human blood for 10 seconds, and the blood was blown off with an air syringe for 5 seconds. Angel I was applied on the contaminated surface; the brackets were then bonded and light cured as in group I. Group III: Angel I was applied as described in group I. The surface was then contaminated with human blood for 10 seconds, and the blood was blown off with an air syringe for 5 seconds. Precoated brackets were then bonded as in groups I and II. Group IV: The enamel surface was contaminated with human blood for 10 seconds and blown off with an air syringe for 5 seconds. The self-etch primer, Angel I, was applied as described earlier, and the surface was recontaminated with human blood for 10 seconds, and the blood was blown off with an air syringe for 5 seconds. The brackets were then bonded as in groups I, II, and III. The results of the analysis of variance (F = 13.31) indicated that the shear bond strengths of the 4 groups were significantly different (P =.001). Tukey HSD posterior tests indicated that the uncontaminated control group had a significantly stronger (mean = 6.0 +/- 3.5 megapascal [MPa]) shear bond strength than the groups that had blood contamination, regardless of whether this occurred before (mean = 2.7 +/- 2.4 MPa), after (mean = 1.1 +/- 0.6 MPa), or before and after (mean = 0.5 +/- 0.2 MPa) the application of the self-etch primer. Blood contamination at any stage of the bonding procedure results in a significant and drastic drop in the shear bond strength of orthodontic brackets.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12750674     DOI: 10.1067/mod.2003.S0889540603000490

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  10 in total

1.  Effect of saliva contamination on shear bond strength of orthodontic brackets when using a self-etch primer.

Authors:  Jing Mao; Juan Qi
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2005

2.  Shear Bond Strength of Ah26 to Human Dentin Treated with Dimethyl Sulfoxide (Dmso).

Authors:  Fotis Dimopoulos; Konstantinos Kodonas; Christos Gogos
Journal:  Dent J (Basel)       Date:  2022-06-06

3.  Influence of blood contamination on bond strength of a self-etching system.

Authors:  Ellen Cristina de Carvalho Mendonça; Samuel Nilo Vieira; Fernando Aparecido Kawaguchi; John Powers; Adriana Bona Matos
Journal:  Eur J Dent       Date:  2010-07

4.  Shear bond strength of brackets bonded with hydrophilic and hydrophobic bond systems under contamination.

Authors:  Bianca Mota Santos; Matheus Melo Pithon; Antonio Carlos de Oliveira Ruellas; Eduardo Franzotti Sant'Anna
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

5.  Effect of saliva and blood contamination on the bond strength of self-etching adhesive system- An in vitro study.

Authors:  Madhusudhana Koppolu; Dorasani Gogala; Vinod B Mathew; Venugopal Thangala; Mandava Deepthi; Nalluru Sasidhar
Journal:  J Conserv Dent       Date:  2012-07

6.  Effect of moisture, saliva, and blood contamination on the shear bond strength of brackets bonded with a conventional bonding system and self-etched bonding system.

Authors:  Mandava Prasad; Shamil Mohamed; Krishna Nayak; Sharath Kumar Shetty; Ashok Kumar Talapaneni
Journal:  J Nat Sci Biol Med       Date:  2014-01

7.  The effect of pre-cure bracket movement on shear bond strength during placement of orthodontic brackets, an in vitro study.

Authors:  Byron Tam; Prashanti Bollu; Kishore Chaudhry; Karthikeyan Subramani
Journal:  J Clin Exp Dent       Date:  2017-10-01

8.  Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood-Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin.

Authors:  Satheesh B Haralur; Salem Mohammed Alharthi; Saeed Aied Abohasel; Khalid Mohammed Alqahtani
Journal:  Healthcare (Basel)       Date:  2019-11-01

9.  Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons.

Authors:  Ahmet Yalçın Güngör; Huseyin Alkis; Hakan Turkkahraman
Journal:  Korean J Orthod       Date:  2013-04-25       Impact factor: 1.372

10.  Effect of a plant-based hemostatic agent on microleakage of self-etching adhesives.

Authors:  Soley Arslan; Hüseyin Ertaş; Yahya-Orçun Zorba
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-01-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.