Literature DB >> 23896357

A new technique for radiographic measurement of acetabular cup orientation.

Brian Derbyshire1, Peter J Diggle2, Christopher J Ingham3, Rory Macnair3, James Wimhurst3, Henry Wynn Jones1.   

Abstract

Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs.
© 2013.

Entities:  

Keywords:  acetabular cup; cup inclination; cup orientation; cup version; radiographic measurement

Mesh:

Year:  2013        PMID: 23896357     DOI: 10.1016/j.arth.2013.06.024

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  Does oversizing an uncemented cup increase post-operative pain in primary total hip arthroplasty?

Authors:  Jonathan A Barrow; Hiren M Divecha; Sunil Panchani; Richard Boden; Martyn L Porter; Tim N Board
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-05-31

2.  Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

Authors:  T Schwarz; M Weber; M Wörner; T Renkawitz; J Grifka; B Craiovan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-10-06       Impact factor: 2.924

3.  Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models.

Authors:  Jaeyeong Park; Jun-Young Kim; Hyun Deok Kim; Young Cheol Kim; Anna Seo; Minkyu Je; Jong Uk Mun; Bia Kim; Il Hyung Park; Shin-Yoon Kim
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-06       Impact factor: 2.924

4.  Accuracy of plain antero-posterior radiographic-based methods for measurement of acetabular cup version.

Authors:  Mohammad Ali Alzohiry; Mohammad Kamal Abdelnasser; Mohamed Moustafa; Mohamed Mahran; Hatem Bakr; Yaser Khalifa; Ahmed Abelaal; Haisam Atta; Galal Zaki Said
Journal:  Int Orthop       Date:  2018-06-04       Impact factor: 3.075

5.  The synergetic effect of pelvic rotation and X-ray offset on radiographic angles of the acetabular cup.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Guo-Fei Sun; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Med Biol Eng Comput       Date:  2019-09-09       Impact factor: 2.602

6.  Two year follow up of supercapsular percutaneously assisted total hip arthroplasty.

Authors:  Andrew Kay; Derek Klavas; Varan Haghshenas; Mimi Phan; Daniel Le
Journal:  BMC Musculoskelet Disord       Date:  2021-05-24       Impact factor: 2.362

7.  Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups.

Authors:  Brian Derbyshire; Bilal Barkatali
Journal:  Med Eng Phys       Date:  2017-07-03       Impact factor: 2.242

8.  2D measurements of cup orientation are less reliable than 3D measurements (Acta Orthop 2015; 86 (4): 485-90.).

Authors: 
Journal:  Acta Orthop       Date:  2016-03-15       Impact factor: 3.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.