Literature DB >> 31448307

Use of a Digital Protractor and a Spirit Level to Determine the Intraoperative Anteversion of Femoral Component during Cemented Hip Hemiarthroplasty: a Prospective Clinical Trial.

Anuwat Pongkunakorn1,2, Patanapong Palawong1,2, Swist Chatmaitri1,2, Nawakun Phetpangnga1,2.   

Abstract

BACKGROUND: Femoral stem anteversion during hip arthroplasty is generally estimated by eye intraoperatively and has proven to be different from targeted values. This study aims to determine the accuracy of a novel technique using a digital protractor and a spirit level to improve surgeons' estimation of stem anteversion.
METHODS: A prospective non-randomized study was conducted among 93 patients with femoral neck fracture who underwent cemented hemiarthroplasty via posterolateral approach. In the control group (N=62), five experienced surgeons assessed stem anteversion related to the posterior femoral condylar plane using visual estimation with a target angle of 15°-25°. In the study group (N=31), another two surgeons assessed stem anteversion with the same target angle by placing a digital protractor on the femoral stem inserter handle while the assistant held the leg in the truly vertical position, verified by a spirit level that was attached to the shin with cable ties. Stem anteversion was measured blind, postoperatively, on 2D-CT and compared with the intraoperative results.
RESULTS: The mean postoperative anteversion was 22.4° (-4.2° to 51.3°, SD 11.1°) in the control group and 23.0° (16.0° to 29.9°, SD 3.6°) in the study group (P=0.810). The study group had more stems positioned in 15°-25° anteversion (71.0% vs 32.3%, P=0.001) and the mean absolute value of surgeon error was -0.2° (-5.4° to 7.0°, SD 3.0°). Twenty-eight stems of the study group (90.3%) had an error within 5°. Surgeon overestimation >5° was found in 1 hip (3.2%) and underestimation >5° was found in 2 hips (6.4%).
CONCLUSION: Using a digital protractor and a spirit level was reliable with high accuracy and precision to improve the intraoperative estimation of cemented stem anteversion.

Entities:  

Keywords:  Digital protractor; Femoral stem anteversion; Hip arthroplasty; Spirit level

Year:  2019        PMID: 31448307      PMCID: PMC6686061     

Source DB:  PubMed          Journal:  Arch Bone Jt Surg        ISSN: 2345-461X


  18 in total

1.  The effect of anteversion on femoral component stability assessed by radiostereometric analysis.

Authors:  H S Gill; J Alfaro-Adrián; C Alfaro-Adrián; P McLardy-Smith; D W Murray
Journal:  J Arthroplasty       Date:  2002-12       Impact factor: 4.757

2.  Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty.

Authors:  Stephen M Howell; Justin Chen; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-05       Impact factor: 4.342

3.  Evaluation of methods that locate the center of the ankle for computer-assisted total knee arthroplasty.

Authors:  Robert A Siston; Aaron C Daub; Nicholas J Giori; Stuart B Goodman; Scott L Delp
Journal:  Clin Orthop Relat Res       Date:  2005-10       Impact factor: 4.176

4.  Influence of design variations on early migration of a cemented stem in THA.

Authors:  Kent Olofsson; Georgios Digas; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2006-07       Impact factor: 4.176

5.  Combined anteversion technique for total hip arthroplasty.

Authors:  Lawrence D Dorr; Aamer Malik; Manish Dastane; Zhinian Wan
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

6.  Computed tomography measurement of the accuracy of component version in total hip arthroplasty.

Authors:  Andrew P Wines; David McNicol
Journal:  J Arthroplasty       Date:  2006-08       Impact factor: 4.757

7.  A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty.

Authors:  Lawrence D Dorr; Zhinian Wan; Aamer Malik; Jinjun Zhu; Manish Dastane; Prashant Deshmane
Journal:  J Bone Joint Surg Am       Date:  2009-11       Impact factor: 5.284

8.  The effect of middle-age body weight and physical activity on the risk of early revision hip arthroplasty: a cohort study of 1,535 individuals.

Authors:  Gunnar B Flugsrud; Lars Nordsletten; Birgitte Espehaug; Leif I Havelin; Haakon E Meyer
Journal:  Acta Orthop       Date:  2007-02       Impact factor: 3.717

Review 9.  Current trends in total hip arthroplasty.

Authors:  Christoph Eingartner
Journal:  Ortop Traumatol Rehabil       Date:  2007 Jan-Feb

10.  Validation of the femoral anteversion measurement method used in imageless navigation.

Authors:  Glen A Turley; Shahbaz M Y Ahmed; Mark A Williams; Damian R Griffin
Journal:  Comput Aided Surg       Date:  2012-06-08
View more
  2 in total

1.  Measurement of operative femoral anteversion during cementless total hip arthroplasty and influencing factors for using neck-adjustable femoral stem.

Authors:  Jingyang Sun; Bohan Zhang; Lei Geng; Qingyuan Zheng; Juncheng Li; Wenzhe Cao; Ming Ni; Guoqiang Zhang
Journal:  J Orthop Surg Res       Date:  2021-05-31       Impact factor: 2.359

2.  Accuracy of intraoperative estimation of femoral stem anteversion in cementless total hip arthroplasty by using a digital protractor and a spirit level.

Authors:  Anuwat Pongkunakorn; Nawakun Phetpangnga; Narawit Kananai
Journal:  J Orthop Surg Res       Date:  2021-01-07       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.