Literature DB >> 16826098

Influence of design variations on early migration of a cemented stem in THA.

Kent Olofsson1, Georgios Digas, Johan Kärrholm.   

Abstract

UNLABELLED: The clinical results of using different cemented stems in total hip arthroplasty may vary because of shape, surface finish, and choice of metal alloy. Less is known about the influence of size and offset using one and the same design. Data from 140 patients (140 hips) of a cohort constituting 197 patients (231 hips) implanted with cemented Spectron Primary stems were extracted from patients studied in four randomized studies primarily designed for other purposes. Stem size (1, 2, 3, or larger), normal/extra offset, neck length and true offset (horizontal length between the stem and head center of the inserted modular implant) were recorded in millimeters. The radiographic appearance of the cementing was graded on the immediate postoperative radiograph according to Barrack. The patients were examined with radiostereometric analysis of stem migration for a 2-year followup period. Stem Size 1 (the smallest) showed an insignificant increase in subsidence compared with the bigger sizes. Using stepwise linear regression analysis, the quality of the cementing (Barrack C2) was the only parameter that had any certain influence of the subsidence at 2 years. Stem size 2 tended to show minimum valgus alignment and sizes 1 and 3 and bigger showed minimum varus tilting. Our findings suggest that placement of the stem with the tip against the posterior cortex (C2) and stem size influence the primary fixation in different ways. This effect is small, however, indicating that further confirmation with longer followup is necessary. LEVEL OF EVIDENCE: Therapeutic Level II-1 (prospective cohort study). See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2006        PMID: 16826098     DOI: 10.1097/01.blo.0000224020.73163.28

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  12 in total

1.  The twenty-year survivorship of two CDH stems with different design features.

Authors:  George Digas; George Georgiades; Kalliopi Lampropoulou-Adamidou; George Hartofilakidis
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-10-18

2.  Is Model-based Radiostereometric Analysis Suitable for Clinical Trials of a Cementless Tapered Wedge Femoral Stem?

Authors:  Sanaz Nazari-Farsani; Sami Finnilä; Niko Moritz; Kimmo Mattila; Jessica J Alm; Hannu T Aro
Journal:  Clin Orthop Relat Res       Date:  2016-06-22       Impact factor: 4.176

3.  Early Subsidence Predicts Failure of a Cemented Femoral Stem With Minor Design Changes.

Authors:  Per-Erik Johanson; Martin Antonsson; Bita Shareghi; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

4.  A prospective randomised radiostereometric analysis trial of SmartSet HV and Palacos R bone cements in primary total hip arthroplasty.

Authors:  Otto S Husby; Kristin Haugan; Pål Benum; Olav A Foss
Journal:  J Orthop Traumatol       Date:  2010-03-03

5.  Design-related risk factors for revision of primary cemented stems.

Authors:  Truike M Thien; Johan Kärrholm
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

6.  Use of a Digital Protractor and a Spirit Level to Determine the Intraoperative Anteversion of Femoral Component during Cemented Hip Hemiarthroplasty: a Prospective Clinical Trial.

Authors:  Anuwat Pongkunakorn; Patanapong Palawong; Swist Chatmaitri; Nawakun Phetpangnga
Journal:  Arch Bone Jt Surg       Date:  2019-07

7.  A randomized study on migration of the Spectron EF and the Charnley flanged 40 cemented femoral components using radiostereometric analysis at 2 years.

Authors:  Thomas Kadar; Geir Hallan; Arild Aamodt; Kari Indrekvam; Mona Badawy; Leif Ivar Havelin; Terje Stokke; Kristin Haugan; Birgitte Espehaug; Ove Furnes
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

Review 8.  Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

Authors:  Paul van der Voort; Bart G Pijls; Marc J Nieuwenhuijse; Jorrit Jasper; Marta Fiocco; Josepha W M Plevier; Saskia Middeldorp; Edward R Valstar; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2015       Impact factor: 3.717

9.  [Femoral offset and hip functioning in total hip prosthesis].

Authors:  Abdelillah Rachid; Erraji Moncef; Abbassi Najib; Najib Abdeljaouad; Daudi Abdelkarim; Yacoubi Hicham
Journal:  Pan Afr Med J       Date:  2014-05-22

10.  Fifteen-year results of precoated femoral stem in primary hybrid total hip arthroplasty.

Authors:  Dong Hun Suh; Ho Hyun Yun; Sung Kwang Chun; Won Yong Shon
Journal:  Clin Orthop Surg       Date:  2013-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.