Literature DB >> 12478509

The effect of anteversion on femoral component stability assessed by radiostereometric analysis.

H S Gill1, J Alfaro-Adrián, C Alfaro-Adrián, P McLardy-Smith, D W Murray.   

Abstract

Internal rotation of a femoral stem within the femur, with posterior migration of the femoral head (PHM) relative to the femur, is an important mode of failure. The relationship between anteversion and rotational stability for the Exeter (Howmedica International Ltd, London, UK) and Charnley Elite (DePuy International Ltd, Leeds, UK) stems was investigated using radiostereometric analysis (RSA). For the Elite, there was a significant (P=.01) correlation between anteversion and PHM, whereas for the Exeter, there was no significant correlation (P=.6). Increasing anteversion of the Elite was associated with decreasing PHM and increased stability. Of stems, 20% of the Elite and none of the Exeter were classified as having reduced rotational stability because their PHM was >2 SDs from the mean. All reduced rotational stability implants had anteversion substantially <20 degrees. Polished collarless tapered stems such as the Exeter seem to have enhanced rotational stability. For conventional stems, increasing anteversion increases stability. It is recommended that these stems are anteverted 20 degrees. Copyright 2002, Elsevier Science (USA). All rights reserved.

Entities:  

Mesh:

Year:  2002        PMID: 12478509     DOI: 10.1054/arth.2002.34531

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Stem-cement porosity may explain early loosening of cemented femoral hip components: experimental-computational in vitro study.

Authors:  Kenneth A Mann; Leatha A Damron; Mark A Miller; Amos Race; Michael T Clarke; Richard J Cleary
Journal:  J Orthop Res       Date:  2007-03       Impact factor: 3.494

2.  3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC system.

Authors:  Yeon Soo Lee; Seung Hoon Oh; Jong Keun Seon; Eun Kyoo Song; Taek Rim Yoon
Journal:  Med Biol Eng Comput       Date:  2006-09-29       Impact factor: 2.602

3.  Component version in modular total hip revision.

Authors:  Michael A Kopec; Aaron Pemberton; Joseph C Milbrandt; Gordon Allan
Journal:  Iowa Orthop J       Date:  2009

4.  Use of a Digital Protractor and a Spirit Level to Determine the Intraoperative Anteversion of Femoral Component during Cemented Hip Hemiarthroplasty: a Prospective Clinical Trial.

Authors:  Anuwat Pongkunakorn; Patanapong Palawong; Swist Chatmaitri; Nawakun Phetpangnga
Journal:  Arch Bone Jt Surg       Date:  2019-07

Review 5.  Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

Authors:  Paul van der Voort; Bart G Pijls; Marc J Nieuwenhuijse; Jorrit Jasper; Marta Fiocco; Josepha W M Plevier; Saskia Middeldorp; Edward R Valstar; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2015       Impact factor: 3.717

Review 6.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

7.  Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis.

Authors:  Cs Georgiou; Kg Evangelou; Eg Theodorou; Cg Provatidis; Pd Megas
Journal:  Open Orthop J       Date:  2012-12-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.