Literature DB >> 18979146

Combined anteversion technique for total hip arthroplasty.

Lawrence D Dorr1, Aamer Malik, Manish Dastane, Zhinian Wan.   

Abstract

UNLABELLED: Combined cup and stem anteversion in THA based on femoral anteversion has been suggested as a method to compensate for abnormal femoral anteversion. We investigated the combined anteversion technique using computer navigation. In 47 THAs, the surgeon first estimated the femoral broach anteversion and validated the position by computer navigation. The broach was then measured with navigation. The navigation screen was blocked while the surgeon estimated the anteversion of the broach. This provided two estimates of stem anteversion. The navigated stem anteversion was validated by postoperative CT scans. All cups were implanted using navigation alone. We determined precision (the reproducibility) and bias (how close the average test number is to the true value) of the stem position. Comparing the surgeon estimate to navigation anteversion, the precision of the surgeon was 16.8 degrees and bias was 0.2 degrees ; comparing the navigation of the stem to postoperative CT anteversion, the precision was 4.8 degrees and bias was 0.2 degrees , meaning navigation is accurate. Combined anteversion by postoperative CT scan was 37.6 degrees +/- 7 degrees (standard deviation) (range, 19 degrees -50 degrees ). The combined anteversion with computer navigation was within the safe zone of 25 degrees to 50 degrees for 45 of 47 (96%) hips. Femoral stem anteversion had a wide variability. LEVEL OF EVIDENCE: Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2008        PMID: 18979146      PMCID: PMC2600986          DOI: 10.1007/s11999-008-0598-4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  30 in total

1.  The effect of diaphyseal biologic fixation on clinical results and fixation of the APR-II stem.

Authors:  J S Kang; L D Dorr; Z Wan
Journal:  J Arthroplasty       Date:  2000-09       Impact factor: 4.757

2.  Optimizing acetabular component position to minimize impingement and reduce contact stress.

Authors:  D D D'Lima; P C Chen; C W Colwell
Journal:  J Bone Joint Surg Am       Date:  2001       Impact factor: 5.284

3.  Comparison of a mechanical acetabular alignment guide with computer placement of the socket.

Authors:  Anthony M Digioia; Branislav Jaramaz; Anton Y Plakseychuk; James E Moody; Constantinos Nikou; Richard S Labarca; Timothy J Levison; Frederic Picard
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

4.  Review of the American College of Radiology--National Electrical Manufacturers' Association standards activity.

Authors:  D E Best; S C Horii; W Bennett; B Thomson; D Snavely
Journal:  Comput Methods Programs Biomed       Date:  1992-05       Impact factor: 5.428

5.  Compliant positioning of total hip components for optimal range of motion.

Authors:  K-H Widmer; B Zurfluh
Journal:  J Orthop Res       Date:  2004-07       Impact factor: 3.494

6.  Influence of component positions on dislocation: computed tomographic evaluations in a consecutive series of total hip arthroplasty.

Authors:  Takashi Nishii; Nobuhiko Sugano; Hidenobu Miki; Tsuyoshi Koyama; Masaki Takao; Hideki Yoshikawa
Journal:  J Arthroplasty       Date:  2004-02       Impact factor: 4.757

7.  Introduction to the ACR-NEMA DICOM standard.

Authors:  W D Bidgood; S C Horii
Journal:  Radiographics       Date:  1992-03       Impact factor: 5.333

8.  Anatomical factors in the stability of the hip joint in the newborn.

Authors:  B McKibbin
Journal:  J Bone Joint Surg Br       Date:  1970-02

9.  Polyethylene wear and acetabular component orientation.

Authors:  Shantanu Patil; Arnie Bergula; Peter C Chen; Clifford W Colwell; Darryl D D'Lima
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

10.  Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement.

Authors:  Brigitte M Jolles; Patrick Genoud; Pierre Hoffmeyer
Journal:  Clin Orthop Relat Res       Date:  2004-09       Impact factor: 4.176

View more
  105 in total

1.  The association between the sagittal femoral stem alignment and the resulting femoral head centre in total hip arthroplasty.

Authors:  Michael Müller; Dirk Crucius; Carsten Perka; Stephan Tohtz
Journal:  Int Orthop       Date:  2010-06-13       Impact factor: 3.075

2.  Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position.

Authors:  Ernst Sendtner; Tibor Schuster; Michael Wörner; Thomas Kalteis; Joachim Grifka; Tobias Renkawitz
Journal:  Int Orthop       Date:  2010-05-21       Impact factor: 3.075

3.  Three-dimensional in vivo difference between native acetabular version and acetabular component version influences iliopsoas impingement after total hip arthroplasty.

Authors:  Kwan Kyu Park; Tsung-Yuan Tsai; Dimitris Dimitriou; Young-Min Kwon
Journal:  Int Orthop       Date:  2015-11-27       Impact factor: 3.075

4.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

5.  Preventing ceramic liner fracture after Delta ceramic-on-ceramic total hip arthroplasty.

Authors:  Young-Kyun Lee; Jae-Young Lim; Yong-Chan Ha; Tae-Young Kim; Woon-Hwa Jung; Kyung-Hoi Koo
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-12       Impact factor: 3.067

6.  Combined anteversion technique reduced the dislocation in cementless total hip arthroplasty.

Authors:  Yasuharu Nakashima; Masanobu Hirata; Mio Akiyama; Takashi Itokawa; Takuaki Yamamoto; Goro Motomura; Masanobu Ohishi; Satoshi Hamai; Yukihide Iwamoto
Journal:  Int Orthop       Date:  2013-09-13       Impact factor: 3.075

7.  Failure of the Durom Metasul acetabular component.

Authors:  William T Long; Manish Dastane; Michael J Harris; Zhinian Wan; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2009-09-02       Impact factor: 4.176

8.  Quantification of pelvic tilt in total hip arthroplasty.

Authors:  Jinjun Zhu; Zhinian Wan; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2009-08-28       Impact factor: 4.176

9.  Computer assisted determination of acetabular cup orientation using 2D-3D image registration.

Authors:  Guoyan Zheng; Xuan Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-02-24       Impact factor: 2.924

10.  Increased anteversion of press-fit femoral stems compared with anatomic femur.

Authors:  Roger H Emerson
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.