Abdullah Saleh Almutairi1, Maher Abdullatif Walid1, Mohamed Ahmed Alkhodary2,3.
Abstract
Background : It is difficult to achieve good primary stability of dental implants in soft bone, such as that in the posterior maxillae. Osseodensification (OD) burs, working in a non-subtractive fashion, condense the implant osteotomy bone in lateral direction and increase in the bone implant contact. Also, dental implants with deeper threads, and decreased thread pitch can increase initial bone implant anchorage.Entities:
Keywords: Implant primary stability; Periotest.; implant thread designs; osseodensification
Mesh:
Substances:
Year: 2018 PMID: 31131085 PMCID: PMC6518436 DOI: 10.12688/f1000research.17292.1
Source DB: PubMed Journal: F1000Res ISSN: 2046-1402
Figure 1. The custom-made dental implants used in this study.
The thread shapes, from left to right, are V-shaped, buttress, reverse buttress, and trapezoid.
Figure 2. Drilling the osseodensification osteotomy using the densah bur after placing the first implant in regular drilling osteotomy.
Figure 3. The osseodensification Densah burs.
Figure 4. Using the Periotest to evaluate the dental implant primary stability, the Periotest tip is applied to the abutment.
Comparison of the Periotest values for primary stability of the different implant threads placed in osseodensification (OD) and regular ostoetomies.
| Thread design | Drilling method | Periotest values for each implant insertion | Mean | SD | P | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| First | Second | Third | Fourth | Fifth | Sixth | |||||
| V-shaped | Regular | -7 | -4.1 | -5.5 | -7.5 | -7.4 | -6.9 | -6.4 | 1.33 | 0.512 |
| OD | -8 | -7.6 | -6.1 | -6.2 | -6.2 | -6.9 | -6.8 | 0.81 | ||
| Trapezoid | Regular | -5.1 | -6.5 | -7.8 | -7.7 | -7.5 | -6.9 | -6.9 | 1.02 | 0.076 |
| OD | -7.2 | -6.8 | -5.3 | -4.4 | -5.1 | -4.6 | -5.6 | 1.16 | ||
| Buttress | Regular | -7.7 | -6.6 | -8 | -8 | -7.7 | -7.7 | -7.6 | 0.51 | 0.06 |
| OD | -8 | -6.9 | -5.9 | -5.8 | -5.3 | -7.8 | -6.6 | 1.12 | ||
| Reverse-buttress | Regular | -7.3 | -6.3 | -7.2 | -7.1 | -7.4 | -7.2 | -7.1 | 0.39 | 0.121 |
| OD | -8 | -7.2 | -6 | -5.6 | -5.8 | -4.9 | -6.3 | 1.13 | ||
Comparison of the Periotest values for primary stability of the all the implant placed in osseodensification (OD) versus those placed in regular ostoetomies.
| Drilling method | Mean | Std. deviation | n | P value |
|---|---|---|---|---|
| Regular | -7.00 | 0.95 | 24 | 0.026 |
| OD | -6.31 | 1.11 | 24 |