Literature DB >> 19709058

The effect of thread pattern upon implant osseointegration.

Heba Abuhussein1, Giorgio Pagni, Alberto Rebaudi, Hom-Lay Wang.   

Abstract

OBJECTIVES: Implant design features such as macro- and micro-design may influence overall implant success. Limited information is currently available. Therefore, it is the purpose of this paper to examine these factors such as thread pitch, thread geometry, helix angle, thread depth and width as well as implant crestal module may affect implant stability. SEARCH STRATEGY: A literature search was conducted using MEDLINE to identify studies, from simulated laboratory models, animal, to human, related to this topic using the keywords of implant thread, implant macrodesign, thread pitch, thread geometry, helix angle, thread depth, thread width and implant crestal module.
RESULTS: The results showed how thread geometry affects the distribution of stress forces around the implant. A decreased thread pitch may positively influence implant stability. Excess helix angles in spite of a faster insertion may jeopardize the ability of implants to sustain axial load. Deeper threads seem to have an important effect on the stabilization in poorer bone quality situations. The addition of threads or microthreads up to the crestal module of an implant might provide a potential positive contribution on bone-to to-implant contact as well as on the preservation of marginal bone; nonetheless this remains to be determined.
CONCLUSIONS: Appraising the current literature on this subject and combining existing data to verify the presence of any association between the selected characteristics may be critical in the achievement of overall implant success.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19709058     DOI: 10.1111/j.1600-0501.2009.01800.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  42 in total

1.  Morphological and structural characteristics of orthodontic mini-implants.

Authors:  Saeed AlSamak; Elias Bitsanis; Margarita Makou; George Eliades
Journal:  J Orofac Orthop       Date:  2012-01-12       Impact factor: 1.938

2.  Biomechanical effects of the implant material and implant-abutment interface in immediately loaded small-diameter implants.

Authors:  Aaron Yu-Jen Wu; Heng-Li Huang; Jui-Ting Hsu; Winston Chee
Journal:  Clin Oral Investig       Date:  2013-09-03       Impact factor: 3.573

3.  Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area.

Authors:  Ting-Hsun Lan; Je-Kang Du; Chin-Yun Pan; Huey-Er Lee; Wei-Hao Chung
Journal:  Clin Oral Investig       Date:  2011-02-08       Impact factor: 3.573

4.  Unravelling the effect of macro and microscopic design of dental implants on osseointegration: a randomised clinical study in minipigs.

Authors:  J V Ríos-Santos; A M Menjívar-Galán; M Herrero-Climent; B Ríos-Carrasco; A Fernández-Palacín; R A Perez; F J Gil
Journal:  J Mater Sci Mater Med       Date:  2018-06-26       Impact factor: 3.896

5.  Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

Authors:  Stefano Tetè; Vincenzo Zizzari; Alessandro De Carlo; Bruna Sinjari; Enrico Gherlone
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

6.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

Review 7.  Modification of polyetheretherketone (PEEK) physical features to improve osteointegration.

Authors:  Dan Yu; Xiaoyue Lei; Huiyong Zhu
Journal:  J Zhejiang Univ Sci B       Date:  2022-03-15       Impact factor: 3.066

8.  Mechanical micromodeling of stress-shielding at the bone-implant interphase under shear loading.

Authors:  Yoann Hériveaux; Sophie Le Cann; Manon Fraulob; Elsa Vennat; Vu-Hieu Nguyen; Guillaume Haïat
Journal:  Med Biol Eng Comput       Date:  2022-09-28       Impact factor: 3.079

9.  Assessment of the Tissue Response to Modification of the Surface of Dental Implants with Carboxyethylphosphonic Acid and Basic Fibroblastic Growth Factor Immobilization (Fgf-2): An Experimental Study on Minipigs.

Authors:  Javier Aragoneses; Ana Suárez; Nansi López-Valverde; Francisco Martínez-Martínez; Juan Manuel Aragoneses
Journal:  Biology (Basel)       Date:  2021-04-23

Review 10.  Nanostructured surfaces of dental implants.

Authors:  Eriberto Bressan; Luca Sbricoli; Riccardo Guazzo; Ilaria Tocco; Marco Roman; Vincenzo Vindigni; Edoardo Stellini; Chiara Gardin; Letizia Ferroni; Stefano Sivolella; Barbara Zavan
Journal:  Int J Mol Sci       Date:  2013-01-17       Impact factor: 5.923