Literature DB >> 19579524

Effect of implant design on initial stability of tapered implants.

Linus Chong1, Ahmed Khocht, Jon B Suzuki, John Gaughan.   

Abstract

Implant design is one of the parameters for achieving successful primary stability. This study aims to examine the effect of a self-tapping blades implant design on initial stability in tapered implants. Polyurethane blocks of different densities were used to simulate different bone densities. The two different implant designs included one with self-tapping blades and one without self-tapping blades. Implants were placed at 3 different depths: apical third, middle third, and fully inserted at 3 different densities of polyurethane blocks. A resonance frequency (RF) analyzer was then used to measure stability of the implants. Repeated-measures analysis of variance was used to examine the effect of implant design, insertion depth, and block density on RF. Analysis of covariance was used to examine the strength of association between RF and the aforementioned factors. In both medium-density (P = .017) and high-density (P = .002) blocks, fully inserted non-self-tapping implants showed higher initial stability than self-tapping implants. No differences were noted between the 2 implant designs that were not fully inserted. The highest strength of association was with insertion depth (standardized beta [std beta] = -0.60, P = .0001), followed by block density (std beta = -0.15, P = .0002). Implant design showed a weak association (std beta = -0.07, P = .09). In conclusion, fully inserted implants without self-tapping blades have higher initial stability than implants with self-tapping blades. However, the association strength between implant design and initial stability is less relevant than other factors, such as insertion depth and block density. Thus, if bone quality and quantity are optimal, they may compensate for design inadequacy.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19579524     DOI: 10.1563/1548-1336-35.3.130

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  16 in total

Review 1.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

2.  Biomechanical effects of the implant material and implant-abutment interface in immediately loaded small-diameter implants.

Authors:  Aaron Yu-Jen Wu; Heng-Li Huang; Jui-Ting Hsu; Winston Chee
Journal:  Clin Oral Investig       Date:  2013-09-03       Impact factor: 3.573

3.  Template-guided vs. non-guided drilling in site preparation of dental implants.

Authors:  Uta Scherer; Marcus Stoetzer; Martin Ruecker; Nils-Claudius Gellrich; Constantin von See
Journal:  Clin Oral Investig       Date:  2014-10-30       Impact factor: 3.573

4.  Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

Authors:  Stefano Tetè; Vincenzo Zizzari; Alessandro De Carlo; Bruna Sinjari; Enrico Gherlone
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

5.  Analysis of primary stability of dental implants inserted in different substrates using the pullout test and insertion torque.

Authors:  Nathalia Ferraz Oliscovicz; Antônio Carlos Shimano; Elcio Marcantonio Junior; César Penazzo Lepri; Andréa Candido Dos Reis
Journal:  Int J Dent       Date:  2013-01-22

Review 6.  Current trends in dental implants.

Authors:  Laura Gaviria; John Paul Salcido; Teja Guda; Joo L Ong
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2014-04-28

7.  Effect of implant design on primary stability using torque-time curves in artificial bone.

Authors:  Yoko Yamaguchi; Makoto Shiota; Motohiro Munakata; Shohei Kasugai; Masahiko Ozeki
Journal:  Int J Implant Dent       Date:  2015-08-08

8.  A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period.

Authors:  Hyun-Joo Kim; Yeun-Kang Kim; Ji-Young Joo; Ju-Youn Lee
Journal:  J Periodontal Implant Sci       Date:  2017-04-29       Impact factor: 2.614

9.  Peri-Implant Bone Behavior after Single Drill versus Multiple Sequence for Osteotomy Drill.

Authors:  Sergio Alexandre Gehrke; Raphaél Bettach; Jaime Sardá Aramburú Júnior; Juan Carlos Prados-Frutos; Massimo Del Fabbro; Jamil Awad Shibli
Journal:  Biomed Res Int       Date:  2018-04-11       Impact factor: 3.411

10.  Development and application of a direct method to observe the implant/bone interface using simulated bone.

Authors:  Yoko Yamaguchi; Makoto Shiota; Masaki FuJii; Michi Sekiya; Masahiko Ozeki
Journal:  Springerplus       Date:  2016-04-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.