The Periotest in traumatology. Part I. Does it have the properties necessary for use as a clinical device and can the measurements be interpreted?

Mary Andresen1, Iain Mackie, Helen Worthington.   

Abstract

The Periotest is a non-invasive, electronic device which provides an objective measurement of the reaction of the periodontium to a defined impact load applied to the tooth crown. In order for a clinician to interpret Periotest readings, normal physiological values must be known. In traumatology, using the contralateral tooth as a control is impractical, as it too may be affected by injury. The main purpose of this research project was to establish the normal physiological Periotest readings for upper permanent incisor teeth at an age when trauma to teeth is at a peak. This was achieved by taking Periotest readings on healthy upper permanent incisors of 250 children aged between 8-12 years. Test-retest reliability was investigated by taking repeated Periotest readings on the teeth of 13 dental nurses at timed intervals over a 2-h period. The practicality of using the device on children was examined by examiner observation and patient questionnaire. Results showed a wide variation of Periotest readings in healthy upper permanent incisor teeth in 8-12-year-olds, and thus it was felt that normal physiological measurements are best expressed as a range. The test-retest reliability of readings was good (R > 0.85) provided that the repeat reading was taken at least 15 min after the initial reading. The examiner found the equipment easy to use and taking measurement was readily acceptable by the sample group. It was concluded that Periotest could be utilised in traumatology, although the clinician needs to take into account the limitations of the device and the difficulty in interpreting the results.

Entities:  

Mesh:

Year:  2003        PMID: 12848715     DOI: 10.1034/j.1600-9657.2003.00165.x

Source DB:  PubMed          Journal:  Dent Traumatol        ISSN: 1600-4469            Impact factor:   3.333


  5 in total

1.  Assessing qualitative changes in simulated periodontal ligament and alveolar bone using a non-contact electromagnetic vibration device.

Authors:  Chiaki Kobayashi; Makoto Hayashi; Masaru Yamaoka; Kazuhiro Hashimoto; Takeshi Kato; Norio Komori; Bunnai Ogiso
Journal:  Clin Oral Investig       Date:  2011-08-02       Impact factor: 3.573

2.  Damping ratio analysis of tooth stability under various simulated degrees of vertical alveolar bone loss and different root types.

Authors:  Kuo-Ning Ho; Sheng-Yang Lee; Haw-Ming Huang
Journal:  Biomed Eng Online       Date:  2017-08-03       Impact factor: 2.819

3.  The effect of osseodensification and different thread designs on the dental implant primary stability.

Authors:  Abdullah Saleh Almutairi; Maher Abdullatif Walid; Mohamed Ahmed Alkhodary
Journal:  F1000Res       Date:  2018-12-05

4.  Influence of preoperative degree of tooth loosening and thickness of wire on the rigidity of wire composite splint.

Authors:  Archana Aravind; Vijay Kumar; Sidhartha Sharma; Amrita Chawla; Ajay Logani
Journal:  J Conserv Dent       Date:  2022-03-07

5.  A study to evaluate mobility of teeth during menstrual cycle using Periotest.

Authors:  Poonam Mishra; P P Marawar; Girish Byakod; Jyoti Mohitey; Sunil S Mishra
Journal:  J Indian Soc Periodontol       Date:  2013-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.