Literature DB >> 31020820

Anterior Segment Optical Coherence Tomography: Applications for Clinical Care and Scientific Research.

Jing Shan1, Charles DeBoer1, Benjamin Y Xu1.   

Abstract

Anterior segment optical coherence tomography (AS-OCT) is a non-contact imaging technique that produces high-resolution images and quantitative measurements of the anterior segment and its anatomical structures. There has been rapid development of OCT technology over the past 2 decades, with the transition from time-domain to Fourier-domain OCT devices. By integrating these advancements in OCT technology, AS-OCT devices have evolved into versatile clinical and research tools for studies of the anterior segment and ocular surface. The primary purpose of this article was to review OCT technology and AS-OCT devices as well as applications of AS-OCT for clinical practice and scientific research. We first describe the different types of OCT technology, how they have been adapted for AS-OCT imaging, and differences between various AS-OCT devices. We then review the applications of AS-OCT for characterizing the anatomical structures of the anterior segment and aqueous outflow pathways, including the anterior chamber angle, trabecular meshwork, and Schlemm canal. We also describe glaucoma-related applications of AS-OCT imaging, which include evaluating patients for static and dynamic biometric risk factors of primary angle closure disease and assessing the efficacy of glaucoma interventions, such as laser peripheral iridotomy and glaucoma surgery. Finally, we review other clinical applications of AS-OCT imaging for detection and management of diseases of the ocular surface, cornea, and lens. Copyright 2019 Asia-Pacific Academy of Ophthalmology.

Entities:  

Keywords:  anterior segment; imaging; optical coherence tomography

Year:  2019        PMID: 31020820      PMCID: PMC7903991          DOI: 10.22608/APO.201910

Source DB:  PubMed          Journal:  Asia Pac J Ophthalmol (Phila)        ISSN: 2162-0989


  84 in total

1.  Increased lens vault as a risk factor for angle closure: confirmation in a Japanese population.

Authors:  Mineo Ozaki; Monisha E Nongpiur; Tin Aung; Mingguang He; Takanori Mizoguchi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-04-12       Impact factor: 3.117

2.  Reduction of intraocular pressure and improvement of vision after cataract surgeries in angle closure glaucoma with concomitant cataract patients.

Authors:  Zong-Mei Zhang; Qing Niu; Yan Nie; Jin Zhang
Journal:  Int J Clin Exp Med       Date:  2015-09-15

3.  Early trabeculectomy bleb walls on anterior-segment optical coherence tomography.

Authors:  Noriko Nakano; Masanori Hangai; Hideo Nakanishi; Ryo Inoue; Noriyuki Unoki; Fumitaka Hirose; Tomonari Ojima; Nagahisa Yoshimura
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-12       Impact factor: 3.117

4.  Quantitative assessment of changes in trabeculectomy blebs after laser suture lysis using anterior segment coherence tomography.

Authors:  Chelvin C A Sng; Mandeep Singh; Paul Tec Kuan Chew; Cheryl S Ngo; Ce Zheng; Tin A Tun; Jovina L S See; Marcus Ang; Seng Chee Loon; Tin Aung
Journal:  J Glaucoma       Date:  2012 Jun-Jul       Impact factor: 2.503

5.  Comparison of dynamic changes in anterior ocular structures examined with anterior segment optical coherence tomography in a cohort of various origins.

Authors:  Fiona E Seager; Joan L Jefferys; Harry A Quigley
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-03-19       Impact factor: 4.799

6.  Diagnostic performance of anterior chamber angle measurements for detecting eyes with narrow angles: an anterior segment OCT study.

Authors:  Arun Narayanaswamy; Lisandro M Sakata; Ming-Guang He; David S Friedman; Yiong-Huak Chan; Raghavan Lavanya; Mani Baskaran; Paul J Foster; Tin Aung
Journal:  Arch Ophthalmol       Date:  2010-10

7.  Repeatability, reproducibility, agreement characteristics of 2 SD-OCT devices for anterior chamber angle measurements.

Authors:  Handan Akil; Anna Dastiridou; Kenneth Marion; Brian Francis; Vikas Chopra
Journal:  Can J Ophthalmol       Date:  2016-11-11       Impact factor: 1.882

8.  Anterior Segment Optical Coherence Tomography and its Clinical Applications in Glaucoma.

Authors:  Haitao Li; Vishal Jhanji; Syril Dorairaj; Andrea Liu; Dennis Sc Lam; Christopher K Leung
Journal:  J Curr Glaucoma Pract       Date:  2012-08-16

9.  Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik.

Authors:  Tommy C Y Chan; Sayantan Biswas; Marco Yu; Vishal Jhanji
Journal:  Medicine (Baltimore)       Date:  2015-07       Impact factor: 1.889

10.  Longitudinal bleb morphology in anterior segment OCT after minimally invasive transscleral ab interno Glaucoma Gel Microstent implantation.

Authors:  Markus Lenzhofer; Clemens Strohmaier; Melchior Hohensinn; Wolfgang Hitzl; Philipp Sperl; Matthias Gerner; Veit Steiner; Sarah Moussa; Eva Krall; Herbert A Reitsamer
Journal:  Acta Ophthalmol       Date:  2018-08-29       Impact factor: 3.761

View more
  11 in total

1.  Anterior segment biometric measurements explain misclassifications by a deep learning classifier for detecting gonioscopic angle closure.

Authors:  Alice Shen; Michael Chiang; Anmol A Pardeshi; Roberta McKean-Cowdin; Rohit Varma; Benjamin Y Xu
Journal:  Br J Ophthalmol       Date:  2021-10-06       Impact factor: 4.638

2.  Ocular Biometric Risk Factors for Progression of Primary Angle Closure Disease: The Zhongshan Angle Closure Prevention Trial.

Authors:  Benjamin Y Xu; David S Friedman; Paul J Foster; Yu Jiang; Natalia Porporato; Anmol A Pardeshi; Yuzhen Jiang; Beatriz Munoz; Tin Aung; Mingguang He
Journal:  Ophthalmology       Date:  2021-10-08       Impact factor: 12.079

3.  Ocular Biometric Determinants of Anterior Chamber Angle Width in Chinese Americans: The Chinese American Eye Study.

Authors:  Benjamin Y Xu; Jacob Lifton; Bruce Burkemper; Xuejuan Jiang; Anmol A Pardeshi; Sasan Moghimi; Grace M Richter; Roberta McKean-Cowdin; Rohit Varma
Journal:  Am J Ophthalmol       Date:  2020-07-28       Impact factor: 5.258

4.  Effect of High Myopia on Dynamic Changes of Anterior Angle After Pharmacologic Mydriasis in Cataract Patients: A SS-ASOCT Study.

Authors:  Wei Wang; Jiaqing Zhang; Xiaoxun Gu; Xuhua Tan; Xiaoting Ruan; Guangyao Yang; Xiaoyun Chen; Guangming Jin; Lanhua Wang; Ye Dai; Zhenzhen Liu; Lixia Luo; Yizhi Liu
Journal:  Transl Vis Sci Technol       Date:  2021-05-03       Impact factor: 3.283

Review 5.  The Value of Anterior Segment Optical Coherence Tomography in Different Types of Corneal Infections: An Update.

Authors:  Ahmed A Abdelghany; Francesco D'Oria; Jorge Alio Del Barrio; Jorge L Alio
Journal:  J Clin Med       Date:  2021-06-27       Impact factor: 4.241

6.  Optimal number and orientation of anterior segment OCT images to measure ocular biometric parameters in angle closure eyes: the Chinese American Eye Study.

Authors:  Jing Shan; Anmol Pardeshi; Xuejuan Jiang; Grace M Richter; Roberta McKean-Cowdin; Rohit Varma; Benjamin Y Xu
Journal:  Br J Ophthalmol       Date:  2022-01-21       Impact factor: 5.908

7.  The anterior and posterior biometric characteristics in primary angle-closure disease: Data based on anterior segment optical coherence tomography and swept-source optical coherence tomography.

Authors:  Wenbin Huang; Xingyi Li; Xinbo Gao; Xiulan Zhang
Journal:  Indian J Ophthalmol       Date:  2021-04       Impact factor: 1.848

Review 8.  Confocal Microscopy and Anterior Segment Optical Coherence Tomography Imaging of the Ocular Surface and Bleb Morphology in Medically and Surgically Treated Glaucoma Patients: A Review.

Authors:  Carmela Carnevale; Ivano Riva; Gloria Roberti; Manuele Michelessi; Lucia Tanga; Alice C Verticchio Vercellin; Luca Agnifili; Gianluca Manni; Alon Harris; Luciano Quaranta; Francesco Oddone
Journal:  Pharmaceuticals (Basel)       Date:  2021-06-18

9.  Deep Neural Network for Scleral Spur Detection in Anterior Segment OCT Images: The Chinese American Eye Study.

Authors:  Benjamin Y Xu; Michael Chiang; Anmol A Pardeshi; Sasan Moghimi; Rohit Varma
Journal:  Transl Vis Sci Technol       Date:  2020-03-30       Impact factor: 3.283

10.  Intradevice Repeatability and Interdevice Agreement of Ocular Biometric Measurements: A Comparison of Two Swept-Source Anterior Segment OCT Devices.

Authors:  Anmol A Pardeshi; Abe E Song; Naim Lazkani; Xiaobin Xie; Alex Huang; Benjamin Y Xu
Journal:  Transl Vis Sci Technol       Date:  2020-08-07       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.