Literature DB >> 31006916

Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS).

Ruixi Zhou1, Yang Yang2,3, Roshin C Mathew2,4, John P Mugler1,2,4, Daniel S Weller5, Christopher M Kramer2,4, Abdul Haseeb Ahmed6, Mathews Jacob6, Michael Salerno1,2,4.   

Abstract

PURPOSE: To develop a continuous-acquisition cardiac self-gated spiral pulse sequence and a respiratory motion-compensated reconstruction strategy for free-breathing cine imaging.
METHODS: Cine data were acquired continuously on a 3T scanner for 8 seconds per slice without ECG gating or breath-holding, using a golden-angle gradient echo spiral pulse sequence. Cardiac motion information was extracted by applying principal component analysis on the gridded 8 × 8 k-space center data. Respiratory motion was corrected by rigid registration on each heartbeat. Images were reconstructed using a low-rank and sparse (L+S) technique. This strategy was evaluated in 37 healthy subjects and 8 subjects undergoing clinical cardiac MR studies. Image quality was scored (1-5 scale) in a blinded fashion by 2 experienced cardiologists. In 13 subjects with whole-heart coverage, left ventricular ejection fraction (LVEF) from SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS) was compared to that from a standard ECG-gated breath-hold balanced steady-state free precession (bSSFP) cine sequence.
RESULTS: The self-gated signal was successfully extracted in all cases and demonstrated close agreement with the acquired ECG signal (mean bias, -0.22 ms). The mean image score across all subjects was 4.0 for reconstruction using the L+S model. There was good agreement between the LVEF derived from SPARCS and the gold-standard bSSFP technique.
CONCLUSION: SPARCS successfully images cardiac function without the need for ECG gating or breath-holding. With an 8-second data acquisition per slice, whole-heart cine images with clinically acceptable spatial and temporal resolution and image quality can be acquired in <90 seconds of free-breathing acquisition.
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  cardiac MRI; golden angle; low-rank and sparse; motion correction; self-gating; spiral trajectory

Year:  2019        PMID: 31006916      PMCID: PMC6510595          DOI: 10.1002/mrm.27763

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  51 in total

Review 1.  Navigator echoes in cardiac magnetic resonance.

Authors:  D Firmin; J Keegan
Journal:  J Cardiovasc Magn Reson       Date:  2001       Impact factor: 5.364

2.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  On NUFFT-based gridding for non-Cartesian MRI.

Authors:  Jeffrey A Fessler
Journal:  J Magn Reson       Date:  2007-07-14       Impact factor: 2.229

4.  Free-breathing Sparse Sampling Cine MR Imaging with Iterative Reconstruction for the Assessment of Left Ventricular Function and Mass at 3.0 T.

Authors:  Sonja Sudarski; Thomas Henzler; Holger Haubenreisser; Christina Dösch; Michael O Zenge; Michaela Schmidt; Mariappan S Nadar; Martin Borggrefe; Stefan O Schoenberg; Theano Papavassiliu
Journal:  Radiology       Date:  2016-07-11       Impact factor: 11.105

5.  Suppression of radiofrequency interference in cardiac gated MRI: a simple design.

Authors:  A N Shetty
Journal:  Magn Reson Med       Date:  1988-09       Impact factor: 4.668

6.  Self-gated golden angle spiral cine MRI for coronary endothelial function assessment.

Authors:  Gabriele Bonanno; Allison G Hays; Robert G Weiss; Michael Schär
Journal:  Magn Reson Med       Date:  2017-12-27       Impact factor: 4.668

7.  Whole-heart cine MRI using real-time respiratory self-gating.

Authors:  Sergio Uribe; Vivek Muthurangu; Redha Boubertakh; Tobias Schaeffter; Reza Razavi; Derek L G Hill; Michael S Hansen
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

8.  Cardiac cine MRI: Quantification of the relationship between fast gradient echo and steady-state free precession for determination of myocardial mass and volumes.

Authors:  Ashkan Akhavan Malayeri; W Craig Johnson; Robson Macedo; Joan Bathon; João A C Lima; David A Bluemke
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813

9.  Whole-heart coronary MRA with 100% respiratory gating efficiency: self-navigated three-dimensional retrospective image-based motion correction (TRIM).

Authors:  Jianing Pang; Himanshu Bhat; Behzad Sharif; Zhaoyang Fan; Louise E J Thomson; Troy LaBounty; John D Friedman; James Min; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2013-02-07       Impact factor: 4.668

10.  Quantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time non-Cartesian GRAPPA.

Authors:  Kestutis J Barkauskas; Prabhakar Rajiah; Ravi Ashwath; Jesse I Hamilton; Yong Chen; Dan Ma; Katherine L Wright; Vikas Gulani; Mark A Griswold; Nicole Seiberlich
Journal:  J Cardiovasc Magn Reson       Date:  2014-09-11       Impact factor: 5.364

View more
  7 in total

1.  Free-Breathing and Ungated Dynamic MRI Using Navigator-Less Spiral SToRM.

Authors:  Abdul Haseeb Ahmed; Ruixi Zhou; Yang Yang; Prashant Nagpal; Michael Salerno; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

2.  Cardiac cine magnetic resonance fingerprinting for combined ejection fraction, T1 and T2 quantification.

Authors:  Jesse I Hamilton; Yun Jiang; Brendan Eck; Mark Griswold; Nicole Seiberlich
Journal:  NMR Biomed       Date:  2020-06-05       Impact factor: 4.044

3.  Ensuring respiratory phase consistency to improve cardiac function quantification in real-time CMR.

Authors:  Chong Chen; Preethi Chandrasekaran; Yingmin Liu; Orlando P Simonetti; Matthew Tong; Rizwan Ahmad
Journal:  Magn Reson Med       Date:  2021-10-31       Impact factor: 4.668

4.  Dual-excitation flip-angle simultaneous cine and T1 mapping using spiral acquisition with respiratory and cardiac self-gating.

Authors:  Ruixi Zhou; Daniel S Weller; Yang Yang; Junyu Wang; Haris Jeelani; John P Mugler; Michael Salerno
Journal:  Magn Reson Med       Date:  2021-02-15       Impact factor: 3.737

5.  Quantification of epicardial fat using 3D cine Dixon MRI.

Authors:  Markus Henningsson; Martin Brundin; Tobias Scheffel; Carl Edin; Federica Viola; Carl-Johan Carlhäll
Journal:  BMC Med Imaging       Date:  2020-07-14       Impact factor: 1.930

6.  Highly Accelerated Real-Time Free-Breathing Cine CMR for Patients With a Cardiac Implantable Electronic Device.

Authors:  Sungtak Hong; KyungPyo Hong; Austin E Culver; Ashitha Pathrose; Bradley D Allen; Jane E Wilcox; Daniel C Lee; Daniel Kim
Journal:  Acad Radiol       Date:  2020-09-02       Impact factor: 3.173

7.  Heart Rate-Independent 3D Myocardial Blood Oxygen Level-Dependent MRI at 3.0 T with Simultaneous 13N-Ammonia PET Validation.

Authors:  Hsin-Jung Yang; Damini Dey; Jane Sykes; John Butler; Heather Biernaski; Michael Kovacs; Xiaoming Bi; Behzad Sharif; Ivan Cokic; Richard Tang; Piotr Slomka; Frank S Prato; Rohan Dharmakumar
Journal:  Radiology       Date:  2020-02-25       Impact factor: 29.146

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.