Literature DB >> 17689121

On NUFFT-based gridding for non-Cartesian MRI.

Jeffrey A Fessler1.   

Abstract

For MRI with non-Cartesian sampling, the conventional approach to reconstructing images is to use the gridding method with a Kaiser-Bessel (KB) interpolation kernel. Recently, Sha et al. [L. Sha, H. Guo, A.W. Song, An improved gridding method for spiral MRI using nonuniform fast Fourier transform, J. Magn. Reson. 162(2) (2003) 250-258] proposed an alternative method based on a nonuniform FFT (NUFFT) with least-squares (LS) design of the interpolation coefficients. They described this LS_NUFFT method as shift variant and reported that it yielded smaller reconstruction approximation errors than the conventional shift-invariant KB approach. This paper analyzes the LS_NUFFT approach in detail. We show that when one accounts for a certain linear phase factor, the core of the LS_NUFFT interpolator is in fact real and shift invariant. Furthermore, we find that the KB approach yields smaller errors than the original LS_NUFFT approach. We show that optimizing certain scaling factors can lead to a somewhat improved LS_NUFFT approach, but the high computation cost seems to outweigh the modest reduction in reconstruction error. We conclude that the standard KB approach, with appropriate parameters as described in the literature, remains the practical method of choice for gridding reconstruction in MRI.

Mesh:

Year:  2007        PMID: 17689121      PMCID: PMC2121589          DOI: 10.1016/j.jmr.2007.06.012

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  3 in total

1.  Sampling density compensation in MRI: rationale and an iterative numerical solution.

Authors:  J G Pipe; P Menon
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

2.  An improved gridding method for spiral MRI using nonuniform fast Fourier transform.

Authors:  Liewei Sha; Hua Guo; Allen W Song
Journal:  J Magn Reson       Date:  2003-06       Impact factor: 2.229

3.  Rapid gridding reconstruction with a minimal oversampling ratio.

Authors:  Philip J Beatty; Dwight G Nishimura; John M Pauly
Journal:  IEEE Trans Med Imaging       Date:  2005-06       Impact factor: 10.048

  3 in total
  69 in total

1.  Improved temporal resolution in cardiac imaging using through-time spiral GRAPPA.

Authors:  Nicole Seiberlich; Gregory Lee; Philipp Ehses; Jeffrey L Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2011-04-26       Impact factor: 4.668

2.  Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

Authors:  Shu Li; Cheong Chan; Jason P Stockmann; Hemant Tagare; Ganesh Adluru; Leo K Tam; Gigi Galiana; R Todd Constable; Sebastian Kozerke; Dana C Peters
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

3.  Accelerating magnetic resonance fingerprinting (MRF) using t-blipped simultaneous multislice (SMS) acquisition.

Authors:  Huihui Ye; Dan Ma; Yun Jiang; Stephen F Cauley; Yiping Du; Lawrence L Wald; Mark A Griswold; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2015-06-08       Impact factor: 4.668

4.  Ultrashort echo time quantitative susceptibility mapping (UTE-QSM) for detection of hemosiderin deposition in hemophilic arthropathy: A feasibility study.

Authors:  Hyungseok Jang; Annette von Drygalski; Jonathan Wong; Jenny Y Zhou; Peter Aguero; Xing Lu; Xin Cheng; Scott T Ball; Yajun Ma; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2020-07-14       Impact factor: 4.668

5.  Deep Learning for Fast and Spatially Constrained Tissue Quantification From Highly Accelerated Data in Magnetic Resonance Fingerprinting.

Authors:  Zhenghan Fang; Yong Chen; Mingxia Liu; Lei Xiang; Qian Zhang; Qian Wang; Weili Lin; Dinggang Shen
Journal:  IEEE Trans Med Imaging       Date:  2019-02-13       Impact factor: 10.048

6.  Fat suppression for ultrashort echo time imaging using a single-point Dixon method.

Authors:  Hyungseok Jang; Michael Carl; Yajun Ma; Saeed Jerban; Tan Guo; Wei Zhao; Eric Y Chang; Jiang Du
Journal:  NMR Biomed       Date:  2019-02-15       Impact factor: 4.044

7.  Reducing contrast contamination in radial turbo-spin-echo acquisitions by combining a narrow-band KWIC filter with parallel imaging.

Authors:  Daniel Neumann; Felix A Breuer; Michael Völker; Tobias Brandt; Mark A Griswold; Peter M Jakob; Martin Blaimer
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

8.  A circular echo planar sequence for fast volumetric fMRI.

Authors:  Christoph Rettenmeier; Danilo Maziero; Yongxian Qian; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2018-10-01       Impact factor: 4.668

9.  Patch based reconstruction of undersampled data (PROUD) for high signal-to-noise ratio and high frame rate contrast enhanced liver imaging.

Authors:  Mitchell A Cooper; Thanh D Nguyen; Bo Xu; Martin R Prince; Michael Elad; Yi Wang; Pascal Spincemaille
Journal:  Magn Reson Med       Date:  2014-12-06       Impact factor: 4.668

Review 10.  Magnetic Resonance Sequences and Rapid Acquisition for MR-Guided Interventions.

Authors:  Adrienne E Campbell-Washburn; Anthony Z Faranesh; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.