Literature DB >> 23401157

Whole-heart coronary MRA with 100% respiratory gating efficiency: self-navigated three-dimensional retrospective image-based motion correction (TRIM).

Jianing Pang1, Himanshu Bhat, Behzad Sharif, Zhaoyang Fan, Louise E J Thomson, Troy LaBounty, John D Friedman, James Min, Daniel S Berman, Debiao Li.   

Abstract

PURPOSE: To develop a three-dimensional retrospective image-based motion correction technique for whole-heart coronary MRA with self-navigation that eliminates both the need to setup a diaphragm navigator and gate the acquisition.
METHODS: The proposed technique uses one-dimensional self-navigation to track the superior-inferior translation of the heart, with which the acquired three-dimensional radial k-space data is segmented into different respiratory bins. Respiratory motion is then estimated in image space using an affine transform model and subsequently this information is used to perform efficient motion correction in k-space. The performance of the proposed technique on healthy volunteers is compared with the conventional navigator gating approach as well as data binning using diaphragm navigator.
RESULTS: The proposed method is able to reduce the imaging time to 7.1±0.5 min from 13.9±2.6 min with conventional navigator gating. The scan setup time is reduced as well due to the elimination of the navigator. The proposed method yields excellent image quality comparable with either conventional navigator gating or the navigator binning approach.
CONCLUSION: We have developed a new respiratory motion correction technique for coronary MRA that enables 1 mm(3) isotropic resolution and whole-heart coverage with 7 min of scan time. Further tests on patient population are needed to determine its clinical usage.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  3D affine transform; 3D radial acquisition; coronary MRA; respiratory motion correction

Mesh:

Year:  2013        PMID: 23401157      PMCID: PMC3655135          DOI: 10.1002/mrm.24628

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

1.  Retrospective adaptive motion correction for navigator-gated 3D coronary MR angiography.

Authors:  Y Wang; R L Ehman
Journal:  J Magn Reson Imaging       Date:  2000-02       Impact factor: 4.813

2.  Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography.

Authors:  A M Taylor; J Keegan; P Jhooti; D N Firmin; D J Pennell
Journal:  J Cardiovasc Magn Reson       Date:  1999       Impact factor: 5.364

3.  Respiratory motion in coronary magnetic resonance angiography: a comparison of different motion models.

Authors:  Dirk Manke; Kay Nehrke; Peter Börnert; Peter Rösch; Olaf Dössel
Journal:  J Magn Reson Imaging       Date:  2002-06       Impact factor: 4.813

4.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

5.  Reduction of transient signal oscillations in true-FISP using a linear flip angle series magnetization preparation.

Authors:  Vibhas S Deshpande; Yiu-Cho Chung; Qiang Zhang; Steven M Shea; Debiao Li
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

6.  Direct monitoring of coronary artery motion with cardiac fat navigator echoes.

Authors:  Thanh D Nguyen; Anthony Nuval; Suresh Mulukutla; Yi Wang
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

7.  Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model.

Authors:  Dirk Manke; Kay Nehrke; Peter Börnert
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

8.  Fast isotropic volumetric coronary MR angiography using free-breathing 3D radial balanced FFE acquisition.

Authors:  C Stehning; P Börnert; K Nehrke; H Eggers; O Dössel
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

9.  Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging.

Authors:  Y Wang; S J Riederer; R L Ehman
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

10.  Free-breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size.

Authors:  Mehdi H Moghari; Raymond H Chan; Susie N Hong; Jaime L Shaw; Lois A Goepfert; Kraig V Kissinger; Beth Goddu; Mark E Josephson; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-02-24       Impact factor: 4.668

View more
  50 in total

Review 1.  Recent Advances in Cardiovascular Magnetic Resonance: Techniques and Applications.

Authors:  Michael Salerno; Behzad Sharif; Håkan Arheden; Andreas Kumar; Leon Axel; Debiao Li; Stefan Neubauer
Journal:  Circ Cardiovasc Imaging       Date:  2017-06       Impact factor: 7.792

2.  Four-dimensional respiratory motion-resolved whole heart coronary MR angiography.

Authors:  Davide Piccini; Li Feng; Gabriele Bonanno; Simone Coppo; Jérôme Yerly; Ruth P Lim; Juerg Schwitter; Daniel K Sodickson; Ricardo Otazo; Matthias Stuber
Journal:  Magn Reson Med       Date:  2016-03-28       Impact factor: 4.668

3.  High-resolution variable-density 3D cones coronary MRA.

Authors:  Nii Okai Addy; R Reeve Ingle; Holden H Wu; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2015-07-14       Impact factor: 4.668

4.  Respiratory optimized data selection for more resilient self-navigated whole-heart coronary MR angiography.

Authors:  Jerome Chaptinel; Davide Piccini; Gabriele Bonanno; Simone Coppo; Pierre Monney; Matthias Stuber; Juerg Schwitter
Journal:  MAGMA       Date:  2016-11-14       Impact factor: 2.310

5.  Whole-heart coronary MR angiography using a 3D cones phyllotaxis trajectory.

Authors:  Mario O Malavé; Corey A Baron; Nii Okai Addy; Joseph Y Cheng; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2018-10-29       Impact factor: 4.668

6.  Patient specific prospective respiratory motion correction for efficient, free-breathing cardiovascular MRI.

Authors:  Michael A Bush; Rizwan Ahmad; Ning Jin; Yingmin Liu; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2019-02-14       Impact factor: 4.668

7.  Accelerated whole-heart coronary MRA using motion-corrected sensitivity encoding with three-dimensional projection reconstruction.

Authors:  Jianing Pang; Behzad Sharif; Reza Arsanjani; Xiaoming Bi; Zhaoyang Fan; Qi Yang; Kuncheng Li; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

8.  Improved respiratory self-navigation for 3D radial acquisitions through the use of a pencil-beam 2D-T2 -prep for free-breathing, whole-heart coronary MRA.

Authors:  Andrew J Coristine; Jerome Chaptinel; Giulia Ginami; Gabriele Bonanno; Simone Coppo; Ruud B van Heeswijk; Davide Piccini; Matthias Stuber
Journal:  Magn Reson Med       Date:  2017-05-31       Impact factor: 4.668

9.  Self-gated 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) using rotating cartesian K-space (ROCK): Validation in children with congenital heart disease.

Authors:  Fei Han; Ziwu Zhou; Eric Han; Yu Gao; Kim-Lien Nguyen; J Paul Finn; Peng Hu
Journal:  Magn Reson Med       Date:  2016-08-16       Impact factor: 4.668

10.  High efficiency coronary MR angiography with nonrigid cardiac motion correction.

Authors:  Jianing Pang; Yuhua Chen; Zhaoyang Fan; Christopher Nguyen; Qi Yang; Yibin Xie; Debiao Li
Journal:  Magn Reson Med       Date:  2016-07-25       Impact factor: 4.668

View more