Literature DB >> 14705049

Self-gated cardiac cine MRI.

Andrew C Larson1, Richard D White, Gerhard Laub, Elliot R McVeigh, Debiao Li, Orlando P Simonetti.   

Abstract

The need for ECG gating presents many difficulties in cardiac magnetic resonance imaging (CMRI). Real-time imaging techniques eliminate the need for ECG gating in cine CMRI, but they cannot offer the spatial and temporal resolution provided by segmented acquisition techniques. Previous MR signal-based techniques have demonstrated an ability to provide cardiac gating information; however, these techniques result in decreased imaging efficiency. The purpose of this work was to develop a new "self-gated" (SG) acquisition technique that eliminates these efficiency deficits by extracting the motion synchronization signal directly from the same MR signals used for image reconstruction. Three separate strategies are proposed for deriving the SG signal from data acquired using radial k-space sampling: echo peak magnitude, kymogram, and 2D correlation. The SG techniques were performed on seven normal volunteers. A comparison of the results showed that they provided cine image series with no significant differences in image quality compared to that obtained with conventional ECG gating techniques. SG techniques represent an important practical advance in clinical MRI because they enable the acquisition of high temporal and spatial resolution cardiac cine images without the need for ECG gating and with no loss in imaging efficiency. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 14705049      PMCID: PMC2396326          DOI: 10.1002/mrm.10664

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  29 in total

1.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Authors:  Dana C Peters; Robert J Lederman; Alexander J Dick; Venkatesh K Raman; Michael A Guttman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

2.  Image formation by induced local interactions. Examples employing nuclear magnetic resonance. 1973.

Authors:  P C Lauterbur
Journal:  Clin Orthop Relat Res       Date:  1989-07       Impact factor: 4.176

3.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

4.  Electrocardiograph-independent, "wireless" cardiovascular cine MR imaging.

Authors:  R D White; C B Paschal; M E Clampitt; T A Spraggins; G W Lenz
Journal:  J Magn Reson Imaging       Date:  1991 May-Jun       Impact factor: 4.813

5.  Using cardiac phase to order reconstruction (CAPTOR): a method to improve diastolic images.

Authors:  J A Feinstein; F H Epstein; A E Arai; T K Foo; M R Hartley; R S Balaban; S D Wolff
Journal:  J Magn Reson Imaging       Date:  1997 Sep-Oct       Impact factor: 4.813

Review 6.  A rapid-gated cine MRI technique.

Authors:  G H Glover; N J Pelc
Journal:  Magn Reson Annu       Date:  1988

7.  Extraction of cardiac and respiratory motion cycles by use of projection data and its applications to NMR imaging.

Authors:  W S Kim; C W Mun; D J Kim; Z H Cho
Journal:  Magn Reson Med       Date:  1990-01       Impact factor: 4.668

8.  RF interference suppression in a cardiac synchronization system operating in a high magnetic field NMR imaging system.

Authors:  A A Damji; R E Snyder; D C Ellinger; F X Witkowski; P S Allen
Journal:  Magn Reson Imaging       Date:  1988 Nov-Dec       Impact factor: 2.546

9.  The effect of rapid rise-time magnetic fields on the ECG of the rat.

Authors:  M J Polson; A T Barker; S Gardiner
Journal:  Clin Phys Physiol Meas       Date:  1982-08

10.  Hazardous situation in the MR bore: induction in ECG leads causes fire.

Authors:  Harald Kugel; Christoph Bremer; Marco Püschel; Roman Fischbach; Horst Lenzen; Bernd Tombach; Hugo Van Aken; Walter Heindel
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

View more
  137 in total

1.  Prospective self-gating for swallowing motion: a feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo.

Authors:  Zhaoyang Fan; Sven Zuehlsdorff; Xin Liu; Debiao Li
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Self-gated PROPELLER-encoded cine cardiac imaging.

Authors:  Chi-Chung Wang; Teng-Yi Huang
Journal:  Int J Cardiovasc Imaging       Date:  2011-11-01       Impact factor: 2.357

Review 3.  Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.

Authors:  El-Sayed H Ibrahim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

4.  Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering.

Authors:  Jin Yamamura; Michael Frisch; Hannes Ecker; Joachim Graessner; Kurt Hecher; Gerhard Adam; Ulrike Wedegärtner
Journal:  Eur Radiol       Date:  2010-07-30       Impact factor: 5.315

5.  Nonrigid motion correction in 3D using autofocusing with localized linear translations.

Authors:  Joseph Y Cheng; Marcus T Alley; Charles H Cunningham; Shreyas S Vasanawala; John M Pauly; Michael Lustig
Journal:  Magn Reson Med       Date:  2012-02-03       Impact factor: 4.668

6.  Self-gated fat-suppressed cardiac cine MRI.

Authors:  R Reeve Ingle; Juan M Santos; William R Overall; Michael V McConnell; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-05-07       Impact factor: 4.668

7.  Self-calibrated trajectory estimation and signal correction method for robust radial imaging using GRAPPA operator gridding.

Authors:  Anagha Deshmane; Martin Blaimer; Felix Breuer; Peter Jakob; Jeffrey Duerk; Nicole Seiberlich; Mark Griswold
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

8.  Improved respiratory self-navigation for 3D radial acquisitions through the use of a pencil-beam 2D-T2 -prep for free-breathing, whole-heart coronary MRA.

Authors:  Andrew J Coristine; Jerome Chaptinel; Giulia Ginami; Gabriele Bonanno; Simone Coppo; Ruud B van Heeswijk; Davide Piccini; Matthias Stuber
Journal:  Magn Reson Med       Date:  2017-05-31       Impact factor: 4.668

9.  Respiratory motion-compensated radial dynamic contrast-enhanced (DCE)-MRI of chest and abdominal lesions.

Authors:  Wei Lin; Junyu Guo; Mark A Rosen; Hee Kwon Song
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

10.  Self-gated 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) using rotating cartesian K-space (ROCK): Validation in children with congenital heart disease.

Authors:  Fei Han; Ziwu Zhou; Eric Han; Yu Gao; Kim-Lien Nguyen; J Paul Finn; Peng Hu
Journal:  Magn Reson Med       Date:  2016-08-16       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.