Literature DB >> 17326164

Whole-heart cine MRI using real-time respiratory self-gating.

Sergio Uribe1, Vivek Muthurangu, Redha Boubertakh, Tobias Schaeffter, Reza Razavi, Derek L G Hill, Michael S Hansen.   

Abstract

Two-dimensional (2D) breath-hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three-dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods, even those that use undersampling techniques, involve breath-holding for periods that are too long for many patients. Free-breathing respiratory gating sequences represent a possible solution for realizing 3D cine imaging. A real-time respiratory self-gating technique for whole-heart cine MRI is presented. The technique enables assessment of cardiac anatomy and function with minimum planning or patient cooperation. Nonangulated isotropic 3D data were acquired from five healthy volunteers and then reformatted into 2D clinical views. The respiratory self-gating technique is shown to improve image quality in free-breathing scanning. In addition, ventricular volumetric data obtained using the 3D approach were comparable to those acquired with the conventional multislice 2D approach.

Entities:  

Mesh:

Year:  2007        PMID: 17326164     DOI: 10.1002/mrm.21156

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  45 in total

Review 1.  Overview of left ventricular outpouchings on cardiac magnetic resonance imaging.

Authors:  Arun Sharma; Sanjeev Kumar
Journal:  Cardiovasc Diagn Ther       Date:  2015-12

Review 2.  Evaluation of left ventricular function using cardiac magnetic resonance imaging.

Authors:  Suchi Grover; Darryl P Leong; Joseph B Selvanayagam
Journal:  J Nucl Cardiol       Date:  2011-04       Impact factor: 5.952

Review 3.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

Review 4.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

5.  Highly efficient 3D motion-compensated abdomen MRI from undersampled golden-RPE acquisitions.

Authors:  Christian Buerger; Claudia Prieto; Tobias Schaeffter
Journal:  MAGMA       Date:  2013-02-13       Impact factor: 2.310

6.  Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.

Authors:  Jing Liu; Pascal Spincemaille; Noel C F Codella; Thanh D Nguyen; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

7.  Self-gated MRI of multiple beat morphologies in the presence of arrhythmias.

Authors:  Francisco Contijoch; Srikant Kamesh Iyer; James J Pilla; Paul Yushkevich; Joseph H Gorman; Robert C Gorman; Harold Litt; Yuchi Han; Walter R T Witschey
Journal:  Magn Reson Med       Date:  2016-08-31       Impact factor: 4.668

8.  Self-gated fat-suppressed cardiac cine MRI.

Authors:  R Reeve Ingle; Juan M Santos; William R Overall; Michael V McConnell; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-05-07       Impact factor: 4.668

9.  Accelerated cardiovascular magnetic resonance of the mouse heart using self-gated parallel imaging strategies does not compromise accuracy of structural and functional measures.

Authors:  David Ratering; Christof Baltes; Carola Dörries; Markus Rudin
Journal:  J Cardiovasc Magn Reson       Date:  2010-07-21       Impact factor: 5.364

10.  Retrospective respiratory self-gating and removal of bulk motion in pulmonary UTE MRI of neonates and adults.

Authors:  Nara S Higano; Andrew D Hahn; Jean A Tkach; Xuefeng Cao; Laura L Walkup; Robert P Thomen; Stephanie L Merhar; Paul S Kingma; Sean B Fain; Jason C Woods
Journal:  Magn Reson Med       Date:  2016-03-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.