Literature DB >> 27399326

Free-breathing Sparse Sampling Cine MR Imaging with Iterative Reconstruction for the Assessment of Left Ventricular Function and Mass at 3.0 T.

Sonja Sudarski1, Thomas Henzler1, Holger Haubenreisser1, Christina Dösch1, Michael O Zenge1, Michaela Schmidt1, Mariappan S Nadar1, Martin Borggrefe1, Stefan O Schoenberg1, Theano Papavassiliu1.   

Abstract

Purpose To prospectively evaluate the accuracy of left ventricle (LV) analysis with a two-dimensional real-time cine true fast imaging with steady-state precession (trueFISP) magnetic resonance (MR) imaging sequence featuring sparse data sampling with iterative reconstruction (SSIR) performed with and without breath-hold (BH) commands at 3.0 T. Materials and Methods Ten control subjects (mean age, 35 years; range, 25-56 years) and 60 patients scheduled to undergo a routine cardiac examination that included LV analysis (mean age, 58 years; range, 20-86 years) underwent a fully sampled segmented multiple BH cine sequence (standard of reference) and a prototype undersampled SSIR sequence performed during a single BH and during free breathing (non-BH imaging). Quantitative analysis of LV function and mass was performed. Linear regression, Bland-Altman analysis, and paired t testing were performed. Results Similar to the results in control subjects, analysis of the 60 patients showed excellent correlation with the standard of reference for single-BH SSIR (r = 0.93-0.99) and non-BH SSIR (r = 0.92-0.98) for LV ejection fraction (EF), volume, and mass (P < .0001 for all). Irrespective of breath holding, LV end-diastolic mass was overestimated with SSIR (standard of reference: 163.9 g ± 58.9, single-BH SSIR: 178.5 g ± 62.0 [P < .0001], non-BH SSIR: 175.3 g ± 63.7 [P < .0001]); the other parameters were not significantly different (EF: 49.3% ± 11.9 with standard of reference, 48.8% ± 11.8 with single-BH SSIR, 48.8% ± 11 with non-BH SSIR; P = .03 and P = .12, respectively). Bland-Altman analysis showed similar measurement errors for single-BH SSIR and non-BH SSIR when compared with standard of reference measurements for EF, volume, and mass. Conclusion Assessment of LV function with SSIR at 3.0 T is noninferior to the standard of reference irrespective of BH commands. LV mass, however, is overestimated with SSIR. © RSNA, 2016 Online supplemental material is available for this article.

Entities:  

Mesh:

Year:  2016        PMID: 27399326     DOI: 10.1148/radiol.2016151002

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  16 in total

1.  Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS).

Authors:  Ruixi Zhou; Yang Yang; Roshin C Mathew; John P Mugler; Daniel S Weller; Christopher M Kramer; Abdul Haseeb Ahmed; Mathews Jacob; Michael Salerno
Journal:  Magn Reson Med       Date:  2019-04-21       Impact factor: 4.668

2.  Complete Free-breathing Adenosine Stress Cardiac MRI Using Compressed Sensing and Motion Correction: Comparison of Functional Parameters, Perfusion, and Late Enhancement with the Standard Breath-holding Examination.

Authors:  Christoph Treutlein; Marco Wiesmüller; Matthias S May; Rafael Heiss; Tobias Hepp; Michael Uder; Wolfgang Wuest
Journal:  Radiol Cardiothorac Imaging       Date:  2019-08-22

3.  Free-breathing Cardiorespiratory Synchronized Cine MRI for Assessment of Left and Right Ventricular Volume and Function in Sedated Children and Adolescents with Impaired Breath-holding Capacity.

Authors:  Amol S Pednekar; Siddharth Jadhav; Cory Noel; Prakash Masand
Journal:  Radiol Cardiothorac Imaging       Date:  2019-06-06

4.  Compressed sensing real-time cine imaging for assessment of ventricular function, volumes and mass in clinical practice.

Authors:  Mathilde Vermersch; Benjamin Longère; Augustin Coisne; Michaela Schmidt; Christoph Forman; Aurélien Monnet; Julien Pagniez; Valentina Silvestri; Arianna Simeone; Emma Cheasty; David Montaigne; François Pontana
Journal:  Eur Radiol       Date:  2019-08-01       Impact factor: 5.315

5.  Accelerated real-time cardiac MRI using iterative sparse SENSE reconstruction: comparing performance in patients with sinus rhythm and atrial fibrillation.

Authors:  Bradley D Allen; Maria L Carr; Michael Markl; Michael O Zenge; Michaela Schmidt; Mariappan S Nadar; Bruce Spottiswoode; Jeremy D Collins; James C Carr
Journal:  Eur Radiol       Date:  2018-01-30       Impact factor: 5.315

6.  Right Ventricular Volume and Function Assessment in Congenital Heart Disease Using CMR Compressed-Sensing Real-Time Cine Imaging.

Authors:  Benjamin Longère; Julien Pagniez; Augustin Coisne; Hedi Farah; Michaela Schmidt; Christoph Forman; Valentina Silvestri; Arianna Simeone; Christos V Gkizas; Justin Hennicaux; Emma Cheasty; Solenn Toupin; David Montaigne; François Pontana
Journal:  J Clin Med       Date:  2021-04-29       Impact factor: 4.241

7.  Optimization of through-time radial GRAPPA with coil compression and weight sharing.

Authors:  James Ahad; Evan Cummings; Dominique Franson; Jesse Hamilton; Nicole Seiberlich
Journal:  Magn Reson Med       Date:  2022-04-15       Impact factor: 3.737

8.  Rapid functional cardiac imaging after gadolinium injection: Evaluation of a highly accelerated sequence with sparse data sampling and iterative reconstruction.

Authors:  Johannes Budjan; Holger Haubenreisser; Thomas Henzler; Sonja Sudarski; Michaela Schmidt; Christina Doesch; Ibrahim Akin; Martin Borggrefe; Nadja M Meßner; Stefan O Schoenberg; Ulrike I Attenberger; Theano Papavassiliu
Journal:  Sci Rep       Date:  2016-12-01       Impact factor: 4.379

9.  Two-center clinical validation and quantitative assessment of respiratory triggered retrospectively cardiac gated balanced-SSFP cine cardiovascular magnetic resonance imaging in adults.

Authors:  Amol S Pednekar; Hui Wang; Scott Flamm; Benjamin Y Cheong; Raja Muthupillai
Journal:  J Cardiovasc Magn Reson       Date:  2018-06-28       Impact factor: 5.364

10.  60-S Retrogated Compressed Sensing 2D Cine of the Heart: Sharper Borders and Accurate Quantification.

Authors:  Benjamin Longère; Christos V Gkizas; Augustin Coisne; Lucas Grenier; Valentina Silvestri; Julien Pagniez; Arianna Simeone; Justin Hennicaux; Michaela Schmidt; Christoph Forman; Solenn Toupin; David Montaigne; François Pontana
Journal:  J Clin Med       Date:  2021-05-29       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.