| Literature DB >> 30139339 |
Işıl Sarıkaya1, Yeliz Hayran2.
Abstract
BACKGROUND: The purpose of this study is to evaluate the wear and fracture strength of crowns and three-unit partial fixed dental prosthesis (FDP) fabricated using by Bruxzir and Incoris TZI as recently introduced monolithic zirconia materials.Entities:
Keywords: Dynamic aging; Fracture strength; Monolithic zirconia; Wear
Mesh:
Substances:
Year: 2018 PMID: 30139339 PMCID: PMC6107961 DOI: 10.1186/s12903-018-0618-z
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Chemical composition of the Y-TZP dental ceramics expressed as weight percent (wt.%)
| Ceramic | wt.% | ||||||
|---|---|---|---|---|---|---|---|
| Y2O3 | HfO2 | Al2O3 | SiO2 | Fe2O3 | Na2O | ZrO2 | |
| Bruxzir | 4.1 | 4.0 | 0.34 | < 0.01 | < 0.01 | < 0.01 | Balance |
| Incoris TZI | 4.5–6.0 | < 5.0 | < 0.05 | < 0.05 | < 0.05 | < 0.05 | Balance |
The configuration of parameters set for dynamic aging
| Parameter | Data |
|---|---|
| Number of cycles | 1.200.000 |
| Force | 49 N |
| Height | 3 mm |
| Lateral movement | 1 mm |
| Descendent speed | 60 mm/s |
| Lifting speed | 60 mm/s |
| Feed speed | 40 mm/s |
| Return speed | 40 mm/s |
| Frequency | 1.6 Hz |
Fig. 1Laser scanner image of the specimen’s with 3-dimensional surface analysis, and the volumetric loss (mm3)
Mean values and standard deviations (SD) for volumetric loss (mm3) of the monolithic zirconias
| Crowns | FDPs | Total | |
|---|---|---|---|
| Bruxzir | 1,43 ± 0,12(a,x) | 1,15 ± 0,17(a,y) | 1,29 ± 0,21(a) |
| Incoris TZI | 1,55 ± 0,11(a,x) | 1,37 ± 0,16(b,y) | 1,46 ± 0,16(b) |
| Total | 1,49 ± 0,13(x) | 1,26 ± 0,2(y) | 1,38 ± 0,2 |
Mean values and standard deviations (SD) for fracture load (N) of the monolithic zirconias
| Crowns | FDPs | Total | |
|---|---|---|---|
| Bruxzir | 4495,00 ± 221,33(a,x) | 4507,25 ± 166,44(a,x) | 4501,13 ± 189,29(a) |
| Incoris TZI | 3566,5 ± 217,24(b,x) | 3327,13 ± 185,81(b,y) | 3446,81 ± 231,12(b) |
| Total | 4030,75 ± 524,2(x) | 3917,19 ± 632,79(y) | 3973,97 ± 574,49 |
Fig. 2a Exemplary SEM picture (Magnification: 100×) of worn surface of a Bruxzir crown after dynamic aging. b Exemplary SEM picture (Magnification: 100×) of worn surface of an Incoris TZI crown after dynamic aging