OBJECTIVES: The objective of this study was to test the hypothesis that industrially manufactured ceramic materials, such as Cerec Mark II and Zirconia-TZP, have a smaller range of fracture strength variation and therefore greater structural reliability than laboratory-processed dental ceramic materials.
METHODS: Thirty bar specimens per material were prepared and tested. The four-point bend test was used to determine the flexure strength of all ceramic materials. The fracture stress values were analyzed by Weibull analysis to determine the Weibull modulus values (m) and the 1 and 5% probabilities of failure.
RESULTS: The mean strength and standard deviation values for these ceramics are as follows: (MPa+/-SD) were: Cerec Mark II, 86.3+/-4.3; Dicor, 70.3+/-12.2; In-Ceram Alumina, 429. 3+/-87.2; IPS Empress, 83.9+/-11.3; Vitadur Alpha Core, 131.0+/-9.5; Vitadur Alpha Dentin, 60.7+/-6.8; Vita VMK 68, 82.7+/-10.0; and Zirconia-TZP, 913.0+/-50.2. There was no statistically significant difference among the flexure strength of Cerec Mark II, Dicor, IPS Empress, Vitadur Alpha Dentin, and Vita VMK 68 ceramics (p>0.05). The highest Weibull moduli were associated with Cerec Mark II and Zirconia-TZP ceramics (23.6 and 18.4). Dicor glass-ceramic and In-Ceram Alumina had the lowest m values (5.5 and 5.7), whereas intermediate values were observed for IPS-Empress, Vita VMK 68, Vitadur Alpha Dentin and Vitadur Alpha Core ceramics (8.6, 8.9, 10.0 and 13.0, respectively).
CONCLUSIONS: Except for In-Ceram Alumina, Vitadur Alpha and Zirconia-TZP core ceramics, most of the investigated ceramic materials fabricated under the condition of a dental laboratory were not stronger or more structurally reliable than Vita VMK 68 veneering porcelain. Only Cerec Mark II and Zirconia-TZP specimens, which were prepared from an industrially optimized ceramic material, exhibited m values greater than 18. Hence, we conclude that industrially prepared ceramics are more structurally reliable materials for dental applications although CAD-CAM procedures may induce surface and subsurface flaws that may adversely affect this property.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10960757     DOI: 10.1016/s0300-5712(00)00030-0

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  46 in total

1.  Early bond strength of two resin cements to Y-TZP ceramic using MPS or MPS/4-META silanes.

Authors:  Mutlu Özcan; Cenk Cura; Luiz Felipe Valandro
Journal:  Odontology       Date:  2011-01-27       Impact factor: 2.634

2.  Damage and reliability of Y-TZP after cementation surface treatment.

Authors:  P C Guess; Y Zhang; J-W Kim; E D Rekow; V P Thompson
Journal:  J Dent Res       Date:  2010-03-30       Impact factor: 6.116

Review 3.  Recent advances in materials for all-ceramic restorations.

Authors:  Jason A Griggs
Journal:  Dent Clin North Am       Date:  2007-07

4.  Parameters affecting retentive force of electroformed double-crown systems.

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; Michael Naumann
Journal:  Clin Oral Investig       Date:  2009-04-03       Impact factor: 3.573

5.  Approximate relative fatigue life estimation methods for thin-walled monolithic ceramic crowns.

Authors:  Sadia Nasrin; Noriko Katsube; Robert R Seghi; Stanislav I Rokhlin
Journal:  Dent Mater       Date:  2018-05       Impact factor: 5.304

6.  Scaling of strength and lifetime probability distributions of quasibrittle structures based on atomistic fracture mechanics.

Authors:  Zdenek P Bazant; Jia-Liang Le; Martin Z Bazant
Journal:  Proc Natl Acad Sci U S A       Date:  2009-06-26       Impact factor: 11.205

7.  Influence of surface treatments and resin cement selection on bonding to zirconia.

Authors:  Meryem Gülce Subaşı; Özgür Inan
Journal:  Lasers Med Sci       Date:  2012-11-09       Impact factor: 3.161

8.  CEREC CAD/CAM Chairside System.

Authors:  G Sannino; F Germano; L Arcuri; E Bigelli; C Arcuri; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2015-04-13

9.  Fatigue behavior in water of Y-TZP zirconia ceramics after abrasion with 30 μm silica-coated alumina particles.

Authors:  Susanne S Scherrer; Maria Cattani-Lorente; Eric Vittecoq; François de Mestral; Jason A Griggs; H W Anselm Wiskott
Journal:  Dent Mater       Date:  2010-11-05       Impact factor: 5.304

10.  Comparison of resin cement adhesion to Y-TZP ceramic following manufacturers' instructions of the cements only.

Authors:  Mutlu Ozcan; Sandra Kerkdijk; Luiz Felipe Valandro
Journal:  Clin Oral Investig       Date:  2007-09-26       Impact factor: 3.573