Literature DB >> 18705807

Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials.

Florian Beuer1, Bastian Steff, Michael Naumann, John A Sorensen.   

Abstract

The purpose of this in vitro study was to compare the load-bearing capacity of posterior three-unit fixed dental prostheses (FDP) produced with three different all-ceramic framework materials: glass-infiltrated alumina (ICA), glass-infiltrated alumina strengthened with zirconia (ICZ), and yttria-stabilized polycrystalline zirconia (YZ). Additionally, the influence on aging of mechanical cyclic fatigue loading and thermal cycling in water were evaluated. A total of 20 frameworks each were fabricated from ICA, ICZ, and YZ by a computer-aided design (CAD)/computer-aided manufacturing (CAM) system. The framework designs were identical for all specimens. All frameworks were veneered with porcelain and cemented with glass-ionomer. Prior to fracture testing, 10 FDP of each experimental group were subjected to thermal and mechanical cycling. Additionally, fractographic analysis was performed. Statistical analysis showed that FDP made from YZ had significantly higher load to failure, whereas no difference was found between the other two materials. Aging did not have a significant effect on the fracture load.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18705807     DOI: 10.1111/j.1600-0722.2008.00551.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  15 in total

1.  Parameters affecting retentive force of electroformed double-crown systems.

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; Michael Naumann
Journal:  Clin Oral Investig       Date:  2009-04-03       Impact factor: 3.573

2.  Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia--an in vitro study.

Authors:  Julian Groesser; Caroline Sachs; Philipp Heiß; Markus Stadelmann; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2013-08-21       Impact factor: 3.573

3.  Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers.

Authors:  Merve Benli; Beril Eker Gümüş; Yusuf Kahraman; Bilge Gökçen-Rohlig; Gülümser Evlioğlu; Olivier Huck; Mutlu Özcan
Journal:  Odontology       Date:  2019-10-14       Impact factor: 2.634

4.  Load-bearing capacity of artificially aged zirconia fixed dental prostheses with heterogeneous abutment supports.

Authors:  Katia Sarafidou; Meike Stiesch; Marc Philipp Dittmer; Daniela Jörn; Lothar Borchers; Philipp Kohorst
Journal:  Clin Oral Investig       Date:  2011-05-24       Impact factor: 3.573

5.  Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology.

Authors:  Moritz Zimmermann; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2019-07-08       Impact factor: 3.573

6.  Effect of ceramic infrastructure on the failure behavior and stress distribution of fixed partial dentures.

Authors:  Márcia Borba; Yuanyuan Duan; Jason A Griggs; Paulo F Cesar; Álvaro Della Bona
Journal:  Dent Mater       Date:  2015-02-02       Impact factor: 5.304

7.  Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs).

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2009-01-24       Impact factor: 3.573

8.  The zirconia ceramic: strengths and weaknesses.

Authors:  Elie E Daou
Journal:  Open Dent J       Date:  2014-04-18

9.  Flexural strengths of implant-supported zirconia based bridges in posterior regions.

Authors:  Mansour Rismanchian; Soufia Shafiei; Farzaneh Nourbakhshian; Amin Davoudi
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

10.  Effect of framework design on fracture resistance of zirconium oxide posterior fixed partial dentures.

Authors:  Hadi Salimi; Ramin Mosharraf; Omid Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.