Literature DB >> 23735078

Fatigue behavior of zirconia-ceramic, galvano-ceramic, and porcelain-fused-to-metal fixed partial dentures.

Zekiye Eroğlu1, Aysegul G Gurbulak1.   

Abstract

PURPOSE: This study evaluated the fatigue behavior of three fixed partial dentures (FPDs) before and after artificial fatigue testing.
MATERIALS AND METHODS: Sixty, three-unit zirconia-ceramic (ZC), galvano-ceramic (GC), and porcelain-fused-to-metal (PFM) FPDs (N = 20) were fabricated. Ten specimens from each group were exposed to fatigue testing by being thermocycled (5 to 55°C, 10,000 cycles) and loaded (100,000 cycles, 50 N, 0.5 Hz). All specimens were then subjected to occlusal loading in a universal testing machine until fracture. The fractures were characterized using scanning electron microscopy. Data were analyzed using one-way ANOVA followed by Tukey's significant difference post hoc test and the paired t-test. The chi-squared test was used to evaluate the type of fracture (α = 0.05).
RESULTS: The mean fracture loads of non-fatigued and fatigued specimens for ZC were 2434.9 ± 154.3 and 2333.1 ± 183.0 N, respectively; for GC were 1678.1 ± 211.6 and 1475.8 ± 227.9 N, respectively; and 1878.5 ± 176.5 and 1687.8 ± 162.2 N, respectively, for PFM restorations. Significant differences were observed between fatigued and non-fatigued specimens of both the GC group and PFM group (p < 0.05), but not between fatigued and non-fatigued ZC specimens (p > 0.05). Differences between the PFM and GC specimens were not statistically significant for fatigued or non-fatigued specimens (p > 0.05). Fracture types did not differ significantly among groups.
CONCLUSIONS: ZC specimens were not significantly affected by fatigue, whereas GC and PFM specimens were affected. All tested restorations have the potential to withstand occlusal forces applied in the posterior region.
© 2013 by the American College of Prosthodontists.

Entities:  

Keywords:  All-ceramic; electroforming; fatigue test; fixed partial denture; zirconia ceramic

Mesh:

Substances:

Year:  2013        PMID: 23735078     DOI: 10.1111/jopr.12059

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  4 in total

1.  Fracture behavior of metal-ceramic fixed dental prostheses with frameworks from cast or a newly developed sintered cobalt-chromium alloy.

Authors:  Klaus-Peter Krug; Andreas W Knauber; Frank P Nothdurft
Journal:  Clin Oral Investig       Date:  2014-03-26       Impact factor: 3.573

2.  Effects of dynamic aging on the wear and fracture strength of monolithic zirconia restorations.

Authors:  Işıl Sarıkaya; Yeliz Hayran
Journal:  BMC Oral Health       Date:  2018-08-23       Impact factor: 2.757

3.  Fatigue Fracture Strength of Implant-Supported Full Contour Zirconia and Metal Ceramic Fixed Partial Dentures.

Authors:  Fariborz Vafaee; Farnaz Firouz; Masoumeh Khoshhal; Amirarsalan Hooshyarfard; Armaghan Shahbazi; Ghodratollah Roshanaei
Journal:  J Dent (Tehran)       Date:  2017-05

4.  Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques.

Authors:  Hasan Kocaağaoğlu; Haydar Albayrak; Sezgi Cinel Sahin; Ayşegül Güleryüz Gürbulak
Journal:  J Adv Prosthodont       Date:  2019-10-30       Impact factor: 1.904

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.