Literature DB >> 29628681

Fallacies of CT based component size prediction in total knee arthroplasty - Are patient specific instruments the answer?

Raju Vaishya1, Vipul Vijay1, Midhun Krishnan2, Amit K Agarwal1.   

Abstract

BACKGROUND: The purpose of the study was to assess the accuracy of tibial and femoral component size prediction using computerised tomography (CT) based patient specific instruments in total knee arthroplasty.
METHODS: Eighty-eight knees in 58 patients underwent total knee arthroplasty (TKA) using CT based patient specific instruments between March 2015 to April 2016. All patients were assessed for the pre operative femoral and tibial component sizes predicted by the CT-based pre-operative plan. These sizes were compared with the actually implanted sizes during surgery, and the results were assessed. The data were evaluated using Wilcoxon signed rank tests, and p value set at <0.05 for significance.
RESULTS: Approximately 72% predicted tibia sizes matched the final implanted sizes whereas 66% femoral implants matched their pre-operative predicted sizes. The difference in the tibial implant size was not statistically significant (p-value > 0.05). However, the difference in the femoral size was statistically significant (p-value 0.009). The downsizing of the tibial component was needed in 14.8% knees whereas upsizing was required in 13.6% of the knees. At the femoral side, 22.7% components required downsizing at the time of implantation as compared to 11.4% components wherein a bigger component was used.
CONCLUSIONS: We conclude that size prediction using CT-based technology for patient specific instrumentation is not fool proof. The size prediction accuracy for femoral and tibial components at 66% and 72% are low and cannot be relied upon at present. The patient specific technology using CT scan based jigs holds promise for the future, needs refining and fine tuning.

Entities:  

Keywords:  Accuracy; Component sizing; Patient specific instruments; Total knee arthroplasty

Year:  2017        PMID: 29628681      PMCID: PMC5884054          DOI: 10.1016/j.jcot.2017.11.001

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  20 in total

1.  Kinemax total knee arthroplasty: trial by template.

Authors:  J Heal; N Blewitt
Journal:  J Arthroplasty       Date:  2002-01       Impact factor: 4.757

2.  Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty.

Authors:  Andrew R Hsu; Jeffrey D Kim; Sanjeev Bhatia; Brett R Levine
Journal:  Orthopedics       Date:  2012-02-17       Impact factor: 1.390

3.  Digital templating in primary total hip and knee arthroplasty.

Authors:  Brett Levine; David Fabi; Carl Deirmengian
Journal:  Orthopedics       Date:  2010-11-02       Impact factor: 1.390

4.  Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees.

Authors:  Bertram The; Ron L Diercks; Peter M A van Ooijen; Jim R van Horn
Journal:  Acta Orthop       Date:  2005-02       Impact factor: 3.717

5.  Computer-assisted total knee arthroplasty using patient-specific templating.

Authors:  M A Hafez; K L Chelule; B B Seedhom; K P Sherman
Journal:  Clin Orthop Relat Res       Date:  2006-03       Impact factor: 4.176

6.  Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems.

Authors:  Kirby Hitt; John R Shurman; Kenneth Greene; Joseph McCarthy; Joseph Moskal; Tim Hoeman; Michael A Mont
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

7.  Patient-specific instrumentation in total knee arthroplasty provides no improvement in component alignment.

Authors:  Benjamin M Stronach; Christopher E Pelt; Jill A Erickson; Christopher L Peters
Journal:  J Arthroplasty       Date:  2014-04-26       Impact factor: 4.757

8.  Brief report: total knee arthroplasty performed with patient-specific, pre-operative CT-guided navigation.

Authors:  Lee E Rubin; Kenneth T Murgo
Journal:  R I Med J (2013)       Date:  2013-03-01

9.  Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique.

Authors:  P P Koch; D Müller; M Pisan; S F Fucentese
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-13       Impact factor: 4.342

10.  Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study.

Authors:  Ola L A Harrysson; Yasser A Hosni; Jamal F Nayfeh
Journal:  BMC Musculoskelet Disord       Date:  2007-09-13       Impact factor: 2.362

View more
  6 in total

Review 1.  Additive manufacturing applications in orthopaedics: A review.

Authors:  Mohd Javaid; Abid Haleem
Journal:  J Clin Orthop Trauma       Date:  2018-04-21

2.  Current status and challenges of Additive manufacturing in orthopaedics: An overview.

Authors:  Mohd Javaid; Abid Haleem
Journal:  J Clin Orthop Trauma       Date:  2018-05-21

3.  Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty.

Authors:  Jaehyun Kim; Seongyun Park; Ji Hyun Ahn
Journal:  Arch Orthop Trauma Surg       Date:  2021-08-17       Impact factor: 2.928

Review 4.  Computed tomography based 3D printed patient specific blocks for total knee replacement.

Authors:  Raju Vaishya; Vipul Vijay; Abhishek Vaish; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2018-07-18

5.  A computational tool for automatic selection of total knee replacement implant size using X-ray images.

Authors:  Thomas A Burge; Gareth G Jones; Christopher M Jordan; Jonathan R T Jeffers; Connor W Myant
Journal:  Front Bioeng Biotechnol       Date:  2022-09-29

Review 6.  Publication trends and knowledge mapping in 3D printing in orthopaedics.

Authors:  Raju Vaishya; Mohit Kumar Patralekh; Abhishek Vaish; Amit Kumar Agarwal; Vipul Vijay
Journal:  J Clin Orthop Trauma       Date:  2018-07-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.