Literature DB >> 11805931

Kinemax total knee arthroplasty: trial by template.

J Heal1, N Blewitt.   

Abstract

A retrospective radiologic study of Kinemax total knee arthroplasty templates is presented to establish their accuracy. The preoperative and postoperative radiographs of 49 Kinemax total knee arthroplasties were assessed using the Kinemax template. The size of the actual component used was compared with that predicted from the preoperative and postoperative radiographs. The preoperative radiograph template was accurate in 57% of cases, but the postoperative radiograph template was accurate in only 41%. Preoperative radiologic templating is of questionable benefit as part of preoperative management for patients undergoing Kinemax total knee arthroplasty.

Entities:  

Mesh:

Year:  2002        PMID: 11805931     DOI: 10.1054/arth.2002.27258

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  The role of pre-operative templating in primary total knee replacement.

Authors:  J Arora; S Sharma; M Blyth
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-10-16       Impact factor: 4.342

2.  Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Ferran Abat; Juan Sarasquete; Juan Carlos Monllau
Journal:  World J Orthop       Date:  2013-10-18

3.  The accuracy and reliability of pre-operative templating in revision total knee arthroplasty. A comparison of analogue and digital methods.

Authors:  Neil Prakash Morgan Jain; Paul Michael Guyver; Michael James Hayden McCarthy; James Press; Jonathan Keenan
Journal:  J Orthop       Date:  2014-07-17

4.  Pre-operative templating for knee arthroplasty shows low accuracy with standard X-rays.

Authors:  Nelson Hiroyuki Miyabe Ooka; André Luiz Siqueira Campos; Vitor Mudesto da Fonseca; Luis Edmundo Oliveira Rodrigues; Edmilson Barbosa Filho; José Sérgio Franco; Rodrigo Satamini Pires E Albuquerque; Vinicius Schott Gameiro
Journal:  Int Orthop       Date:  2018-01-15       Impact factor: 3.075

5.  Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery.

Authors:  Fangyang Shen; Bailiang Chen; Qingshan Guo; Yue Qi; Yue Shen
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-06-30       Impact factor: 2.924

6.  Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty.

Authors:  Jaehyun Kim; Seongyun Park; Ji Hyun Ahn
Journal:  Arch Orthop Trauma Surg       Date:  2021-08-17       Impact factor: 2.928

7.  Fallacies of CT based component size prediction in total knee arthroplasty - Are patient specific instruments the answer?

Authors:  Raju Vaishya; Vipul Vijay; Midhun Krishnan; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2017-11-10

8.  Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis.

Authors:  A J Kievit; J G G Dobbe; G J Streekstra; L Blankevoort; M U Schafroth
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-09-25       Impact factor: 4.342

9.  Digital templating and preoperative deformity analysis with standard imaging software.

Authors:  Amir A Jamali
Journal:  Clin Orthop Relat Res       Date:  2009-05-15       Impact factor: 4.176

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.