Literature DB >> 22310403

Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty.

Andrew R Hsu1, Jeffrey D Kim, Sanjeev Bhatia, Brett R Levine.   

Abstract

The use of digital radiography and templating software continues to become more prevalent in orthopedics as the number of total hip arthroplasty (THA) and total knee arthroplasty (TKA) procedures increases every year. The purpose of this study was to evaluate the effect of training level on the accuracy of digital templating for primary THA and TKA. Digital radiographs of 97 patients undergoing primary THA (49 cases) and TKA (48 cases) were retrospectively templated using OrthoView digital planning software (OrthoView LLC, Jacksonville, Florida). Anteroposterior hip and lateral knee radiographs were digitally templated and compared with the actual size of the implants used intraoperatively. An implant sales representative, physician assistant, medical student (J.D.K.), resident (A.R.H.), and fellowship-trained arthroplasty surgeon (B.R.L.) templated all cases independently after a standardized orientation and were blinded to the actual component sizes used for surgery. The medical student, resident, and arthroplasty surgeon retemplated the same 97 cases 1 month later to determine intraobserver reliability. Digital templating was accurate in predicting the correct implant size in 33% of THAs and 54% of TKAs. In 73% of THAs and 92% of TKAs, digital templating was within 1 size of the actual implant used, and in 88% of THAs and 99% of TKAs, templating was within 2 sizes of the final components. In no cases did the templated implant size vary by >3 sizes from the final components. Interobserver reliability for templating THAs and TKAs showed good reliability as measured by intraclass correlation coefficient (ICC) (ICC(THA)=.70; ICC(TKA)=.86). Intraobserver reliability for templating THAs had excellent reliability for the resident and arthroplasty surgeon, with a kappa coefficient (κ) of 0.92, and good reliability for the medical student (κ=0.78). Intraobserver reliability for templating TKAs showed excellent reliability among all examiners (κ=0.90). Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22310403     DOI: 10.3928/01477447-20120123-15

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  11 in total

1.  Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Ferran Abat; Juan Sarasquete; Juan Carlos Monllau
Journal:  World J Orthop       Date:  2013-10-18

2.  The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty.

Authors:  Florian Schmidutz; Arnd Steinbrück; Lorenz Wanke-Jellinek; Matthias Pietschmann; Volkmar Jansson; Andreas Fottner
Journal:  Int Orthop       Date:  2012-04-04       Impact factor: 3.075

3.  Pre-operative templating for knee arthroplasty shows low accuracy with standard X-rays.

Authors:  Nelson Hiroyuki Miyabe Ooka; André Luiz Siqueira Campos; Vitor Mudesto da Fonseca; Luis Edmundo Oliveira Rodrigues; Edmilson Barbosa Filho; José Sérgio Franco; Rodrigo Satamini Pires E Albuquerque; Vinicius Schott Gameiro
Journal:  Int Orthop       Date:  2018-01-15       Impact factor: 3.075

4.  Patient-specific instruments for total knee arthroplasty can accurately predict the component size as used peroperative.

Authors:  Martijn G M Schotanus; Daphne A L Schoenmakers; Rob Sollie; Nanne P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-05       Impact factor: 4.342

5.  Machine learning algorithms predict within one size of the final implant ultimately used in total knee arthroplasty with good-to-excellent accuracy.

Authors:  Kyle N Kunze; Evan M Polce; Arpan Patel; P Maxwell Courtney; Scott M Sporer; Brett R Levine
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-01-13       Impact factor: 4.114

6.  The accuracy and inter-observer reliability of acetate templating in total hip arthroplasty.

Authors:  R Kearney; A H Shaikh; J M O'Byrne
Journal:  Ir J Med Sci       Date:  2013-01-25       Impact factor: 1.568

7.  Fallacies of CT based component size prediction in total knee arthroplasty - Are patient specific instruments the answer?

Authors:  Raju Vaishya; Vipul Vijay; Midhun Krishnan; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2017-11-10

Review 8.  The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis.

Authors:  Joshua B V Smith; Habeeb Bishi; Chao Wang; Vipin Asopa; Richard E Field; David H Sochart
Journal:  EFORT Open Rev       Date:  2021-11-19

9.  Robotic arm-assisted total knee arthroplasty improves preoperative planning and intraoperative decision-making.

Authors:  Xufeng Wan; Qiang Su; Duan Wang; Mingcheng Yuan; Yahao Lai; Hong Xu; Zongke Zhou
Journal:  J Orthop Surg Res       Date:  2021-11-15       Impact factor: 2.359

10.  Agreement in component size between preoperative measurement, navigation and final implant in total knee replacement.

Authors:  Daniel Hernández-Vaquero; Alfonso Noriega-Fernandez; Sergio Roncero-Gonzalez; Ivan Perez-Coto; Andres A Sierra-Pereira; Manuel A Sandoval-Garcia
Journal:  J Orthop Translat       Date:  2018-11-22       Impact factor: 5.191

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.