Franziska Haupt1, M Hülsmann2. 1. Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany. franziska.haupt@med.uni-goettingen.de. 2. Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
Abstract
OBJECTIVES: To assess the consistency of electronic determination of endodontic working length obtained from four identical electronic root canal length measurement devices (ERCLMD) from five different types of ERCLMD each under various in vitro conditions. MATERIALS AND METHODS: Eight extracted teeth, seven single-rooted teeth, and one molar were accessed. Root length was measured and instruments were inserted and fixed with the tip placed beyond and short of the apical constriction, in roots with an artificial perforation or an open apex. Devices tested were Root ZX (Morita, Kyoto, Japan), Dentaport ZX (Morita), Apex ID (SybronEndo, Glendora, USA), ProPex II (Dentsply Maillefer, Victoria, Australia), and Raypex 6 (VDW-Antaeos, Munich, Germany). Teeth were irrigated with different solutions (NaOCl, EDTA, CHX). ERCLMDs were connected and measurements were recorded. Consistency was classified by the scores 0-4. Comparisons were carried out using the Kruskal-Wallis test (α = 0.05). For multiple testing, the level of significance was adjusted and analysis was performed using the Mann-Whitney U test. RESULTS: Among the five types of ERCLMD, Apex ID and Raypex 6 showed the highest consistency. There was no statistically significant difference between the settings and conditions. Raypex 6 showed the highest consistency for measurements in case of a perforation. CONCLUSION: Different devices from one type of ERCLMD show a high consistency. Nevertheless, general statements on the accuracy of one type of ERCLMD taken from studies investigating only one device per type should be drawn with caution. CLINICAL RELEVANCE: The study refers to the reliability and repeatability of determination of endodontic working length by using ERCLMDs.
OBJECTIVES: To assess the consistency of electronic determination of endodontic working length obtained from four identical electronic root canal length measurement devices (ERCLMD) from five different types of ERCLMD each under various in vitro conditions. MATERIALS AND METHODS: Eight extracted teeth, seven single-rooted teeth, and one molar were accessed. Root length was measured and instruments were inserted and fixed with the tip placed beyond and short of the apical constriction, in roots with an artificial perforation or an open apex. Devices tested were Root ZX (Morita, Kyoto, Japan), Dentaport ZX (Morita), Apex ID (SybronEndo, Glendora, USA), ProPex II (Dentsply Maillefer, Victoria, Australia), and Raypex 6 (VDW-Antaeos, Munich, Germany). Teeth were irrigated with different solutions (NaOCl, EDTA, CHX). ERCLMDs were connected and measurements were recorded. Consistency was classified by the scores 0-4. Comparisons were carried out using the Kruskal-Wallis test (α = 0.05). For multiple testing, the level of significance was adjusted and analysis was performed using the Mann-Whitney U test. RESULTS: Among the five types of ERCLMD, Apex ID and Raypex 6 showed the highest consistency. There was no statistically significant difference between the settings and conditions. Raypex 6 showed the highest consistency for measurements in case of a perforation. CONCLUSION: Different devices from one type of ERCLMD show a high consistency. Nevertheless, general statements on the accuracy of one type of ERCLMD taken from studies investigating only one device per type should be drawn with caution. CLINICAL RELEVANCE: The study refers to the reliability and repeatability of determination of endodontic working length by using ERCLMDs.
Entities:
Keywords:
Electronic root canal length measurement device; Intra-device consistency; Open apex; Perforation; Working length
Authors: Járcio V Baldi; Fausto R Victorino; Ricardo A Bernardes; Ivaldo G de Moraes; Clóvis M Bramante; Roberto B Garcia; Norberti Bernardineli Journal: J Endod Date: 2007-02-22 Impact factor: 4.171
Authors: Bruno Carvalho de Vasconcelos; Michelli de Medeiros Bueno; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes Journal: J Appl Oral Sci Date: 2013 Mar-Apr Impact factor: 2.698
Authors: Carlos G Adorno; Sandra M Solaeche; Ileana E Ferreira; Andrea Pedrozo; Patricia M Escobar; Vicente R Fretes Journal: Clin Oral Investig Date: 2021-02-13 Impact factor: 3.573