Literature DB >> 21306402

Comparison of working length determination with radiographs and four electronic apex locators.

J P Vieyra1, J Acosta.   

Abstract

AIM: To evaluate the accuracy of the Root ZX, Elements-Diagnostic, Precision AL and Raypex 5 electronic apex locators when compared to radiographs for locating the apical constriction.
METHODOLOGY: The apical constriction of 693 canals in 245 maxillary and mandibular teeth was located in vivo with four electronic apex locators (EALs) and radiographically. After extraction the actual location of the apical constriction was determined visually and with magnification. A paired samples t-test, X2 test and a repeated measure anova at the 0.05 level of significance were used to determine differences between the groups.
RESULTS: For anterior teeth, the Root ZX, Elements, Precision AL, Raypex 5 and radiographs located the apical constriction 89.09%, 83.63%, 85.45%, 81.81% and 32.72% of the time, respectively. For premolar teeth, the Root ZX, Elements, Precision AL, Raypex 5 and radiographs located the apical constriction 75%, 61.60%, 64.28%, 61.60% and 32.14% of the time, respectively. For molar teeth, the Root ZX, Elements, Precision AL, Raypex 5 and radiographs located the apical constriction 69.01%, 50.49%, 65.40%, 43.93% and 14.59% of the time, respectively. There was no statistically significant difference between the four EALs (P = 0.05).
CONCLUSION: Measuring the location of the apical constriction using the four apex locators was more accurate than radiographs and would reduce the risk of instrumenting and filling beyond the apical foramen.
© 2011 International Endodontic Journal.

Mesh:

Year:  2011        PMID: 21306402     DOI: 10.1111/j.1365-2591.2011.01855.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  17 in total

1.  Comparison between two thermoplastic root canal obturation techniques regarding extrusion of root canal filling--a retrospective in vivo study.

Authors:  Christian Tennert; Ingo Lars Jungbäck; Karl-Thomas Wrbas
Journal:  Clin Oral Investig       Date:  2012-05-01       Impact factor: 3.573

2.  An ex vivo comparison of working length determination by three electronic root canal length measurement devices integrated into endodontic rotary motors.

Authors:  Manal Maree Ali; Ronald Wigler; Shaul Lin; Arieh Y Kaufman
Journal:  Clin Oral Investig       Date:  2016-07-09       Impact factor: 3.573

3.  Consistency of electronic measurements of endodontic working length when using multiple devices from the same manufacturer-an in vitro study.

Authors:  Franziska Haupt; M Hülsmann
Journal:  Clin Oral Investig       Date:  2018-03-07       Impact factor: 3.573

4.  Accuracy of five electronic foramen locators with different operating systems: an ex vivo study.

Authors:  Bruno Carvalho de Vasconcelos; Michelli de Medeiros Bueno; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

5.  Effect of pre-flaring and file size on the accuracy of two electronic apex locators.

Authors:  Manoel Brito-Júnior; Carla Cristina Camilo; Gil Moreira-Júnior; Jesus Djalma Pecora; Manoel Damião Sousa-Neto
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

6.  Efficiency of 2 electronic apex locators on working length determination: A clinical study.

Authors:  Sibel Koçak; Mustafa Murat Koçak; Baran Can Sağlam
Journal:  J Conserv Dent       Date:  2013-05

7.  Digital radiography for determination of primary tooth length: in vivo and ex vivo studies.

Authors:  Maria D Basso; Fabiano Jeremias; Rita C L Cordeiro; Lourdes Santos-Pinto
Journal:  ScientificWorldJournal       Date:  2015-02-23

8.  Comparison of third generation versus fourth generation electronic apex locators in detecting apical constriction: An in vivo study.

Authors:  D V Swapna; Akash Krishna; Anand C Patil; K Rashmi; Veena S Pai; M A Ranjini
Journal:  J Conserv Dent       Date:  2015 Jul-Aug

9.  Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator.

Authors:  Emel Uzunoglu; Ayhan Eymirli; Mehmet Özgür Uyanik; Semra Çalt; Emre Nagas
Journal:  Restor Dent Endod       Date:  2014-11-05

10.  In vitro comparison of working length determination using three different electronic apex locators.

Authors:  Alper Kuştarci; Dilara Arslan; Demet Altunbaş
Journal:  Dent Res J (Isfahan)       Date:  2014-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.