Comparison of in vivo and in vitro readings when testing the accuracy of the Root ZX apex locator.

Fernando Duran-Sindreu1, Eva Stöber, Montse Mercadé, Jorge Vera, Marc Garcia, Rufino Bueno, Miguel Roig.   

Abstract

INTRODUCTION: The purpose of the study was to compare the accuracy of the Root ZX electronic apex locator (J Morita Corp, Tokyo, Japan) between an in vivo and an in vitro model.
METHODS: The working length (WL) was determined electronically for 46 root canals of human teeth with a 15 K-file using both in vitro (n = 23) and in vivo (n = 23) models. The files were fixed at the WL. The apical 4 mm of each canal was trimmed to expose the file tip. The samples were observed under a scanning electron microscope, and the distance from the file tip to the point 0.5 mm coronal to the major foramen (the final WL) was measured. The data were analyzed using the Student t test, and significance was set at P ≤ .05.
RESULTS: The statistical analysis revealed no significant differences between the in vivo group and in vitro group with respect to the accuracy of the Root ZX device in determining the final WL. The mean distance from the final WL to the file tip was 0.23 ± 0.39 mm for the in vivo group and 0.29 ± 0.32 mm for the in vitro group. In determining the final WL, the Root ZX was accurate 78.3% of the time to ±0.5 mm and 100% of the time to ±1 mm in the in vivo group, whereas it was accurate 74% of the time to ±0.5 mm and 100% of the time to ±1 mm in the in vitro group.
CONCLUSIONS: No statistically significant differences were observed between the in vivo group and the in vitro group.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22244644     DOI: 10.1016/j.joen.2011.10.008

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Consistency of electronic measurements of endodontic working length when using multiple devices from the same manufacturer-an in vitro study.

Authors:  Franziska Haupt; M Hülsmann
Journal:  Clin Oral Investig       Date:  2018-03-07       Impact factor: 3.573

2.  Accuracy of five electronic foramen locators with different operating systems: an ex vivo study.

Authors:  Bruno Carvalho de Vasconcelos; Michelli de Medeiros Bueno; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

3.  Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

Authors:  Pil-Jong Kim; Hong-Gee Kim; Byeong-Hoon Cho
Journal:  Restor Dent Endod       Date:  2014-12-26

4.  Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: an in vivo study.

Authors:  S Moscoso; K Pineda; J Basilio; C Alvarado; M Roig; F Duran-Sindreu
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-03-01

5.  Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator.

Authors:  Emel Uzunoglu; Ayhan Eymirli; Mehmet Özgür Uyanik; Semra Çalt; Emre Nagas
Journal:  Restor Dent Endod       Date:  2014-11-05

6.  In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.

Authors:  Ugur Aydin; Emrah Karataslioglu; Fatih Aksoy; Cihan Yildirim
Journal:  J Conserv Dent       Date:  2015 Jan-Feb

7.  A comparative assessment of the accuracies of Raypex 5, Raypex 6, iPex and iPex II electronic apex locators: An in vitro study.

Authors:  Mugem Asli Gurel; Bagdagul Helvacioglu Kivanc; Adil Ekici
Journal:  J Istanb Univ Fac Dent       Date:  2017-01-02

8.  Root ZX Electronic Foramen Locator: An Ex Vivo Study of Its Three Models' Precision and Reproducibility.

Authors:  Bernardo Almeida Aguiar; Rafael Santos Reinaldo; Luciana Maria Arcanjo Frota; Mônica Sampaio do Vale; Bruno Carvalho de Vasconcelos
Journal:  Int J Dent       Date:  2017-03-07

9.  Influence of Root Canal Curvature on the Accuracy of Root ZX Electronic Foramen Locator: An In Vitro Study.

Authors:  Masoud Saatchi; Shiva Iravani; Mehrdad Akhavan Khaleghi; Amin Mortaheb
Journal:  Iran Endod J       Date:  2017
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.