Literature DB >> 33580848

The influence of periapical lesions on the repeatability of two electronic apex locators in vivo.

Carlos G Adorno1, Sandra M Solaeche2, Ileana E Ferreira2, Andrea Pedrozo2, Patricia M Escobar3, Vicente R Fretes2.   

Abstract

OBJECTIVES: To determine the influence of periapical lesions on the repeatability of two electronic apex locators (EALs), Root ZX II, and RomiApex A-15, in maxillary anterior teeth, in vivo.
MATERIALS AND METHODS: After approval by the local ethics committee, 43 maxillary anterior teeth scheduled for root canal therapy were assigned to two groups. The periapical lesion (PAL) group included 21 teeth with necrotic pulps and radiographically visible periapical lesion, and the normal periapex (NPA) group consisted of 22 teeth with vital pulps and no periapical lesion. In each canal, Root ZX II and RomiApex A-15 were used to determine working length defined as the "zero" reading on the display. Two consecutive measurements were performed with each EAL on each tooth and a second operator measured the endodontic file with a digital caliper without knowledge of the EAL being used or the tooth diagnosis. The absolute value of the difference between the first and second measurement (measurement pairs) was calculated. Repeatability was evaluated by the Bland-Altman method, and an aligned ranks transformation ANOVA was conducted to compare the EALs.
RESULTS: The median absolute difference between measurement pairs was significantly lower (p < 0.001) and the limits of agreement were narrower in the NPA group. Among the EALs, median absolute differences were significantly smaller for Root ZX (p < 0.001).
CONCLUSIONS: Measurements were more repeatable when no periapical lesion was present. Root ZX showed better repeatability than RomiApex. CLINICAL RELEVANCE: Periapical lesions seem to influence successive in vivo measurements with EALs.

Entities:  

Keywords:  Electronic apex locator; Endodontics; Periapical periodontitis; Repeatability; Root canal therapy

Year:  2021        PMID: 33580848     DOI: 10.1007/s00784-021-03831-w

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  34 in total

1.  The sensitivity, specificity, and reliability of radiographic periapical diagnosis of posterior teeth.

Authors:  R N Bohay
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2000-05

2.  Effect of working length measurement by electronic apex locator or radiography on the adequacy of final working length: a randomized clinical trial.

Authors:  Shohreh Ravanshad; Alireza Adl; Javad Anvar
Journal:  J Endod       Date:  2010-09-19       Impact factor: 4.171

Review 3.  The fundamental operating principles of electronic root canal length measurement devices.

Authors:  M H Nekoofar; M M Ghandi; S J Hayes; P M H Dummer
Journal:  Int Endod J       Date:  2006-08       Impact factor: 5.264

4.  Unevenness of the apical constriction in human maxillary central incisors.

Authors:  David G Olson; Steven Roberts; Anthony P Joyce; D Edward Collins; James C McPherson
Journal:  J Endod       Date:  2008-02       Impact factor: 4.171

5.  A prospective study of the factors affecting outcomes of nonsurgical root canal treatment: part 1: periapical health.

Authors:  Y-L Ng; V Mann; K Gulabivala
Journal:  Int Endod J       Date:  2011-03-02       Impact factor: 5.264

6.  A comparative evaluation of two working length determination methods.

Authors:  Georgios Keratiotis; Nikolaos Kournetas; Anastasia Agrafioti; Evangelos G Kontakiotis
Journal:  Aust Endod J       Date:  2018-10-22       Impact factor: 1.659

7.  Validity of longitudinal sections for determining the apical constriction.

Authors:  S Schell; M S Judenhofer; J G Mannheim; M Hülber-J; C Löst; B J Pichler; A ElAyouti
Journal:  Int Endod J       Date:  2016-07-07       Impact factor: 5.264

8.  The Use of Micro-Computed Tomography to Determine the Accuracy of 2 Electronic Apex Locators and Anatomic Variations Affecting Their Precision.

Authors:  Lucila Piasecki; Everdan Carneiro; Ulisses Xavier da Silva Neto; Vânia Portela Ditzel Westphalen; Christian Giampietro Brandão; Gianluca Gambarini; Adham A Azim
Journal:  J Endod       Date:  2016-06-09       Impact factor: 4.171

9.  Changes in Root Canal Length Determined during Mechanical Preparation Stages and Their Relationship with the Accuracy of Root ZX II.

Authors:  Bruno Carvalho Vasconcelos; Luzia Mesquista Bastos; Ariany Souza Oliveira; Ricardo Affonso Bernardes; Marco Antonio Hungaro Duarte; Nilton Vivacqua-Gomes; Rodrigo Ricci Vivan
Journal:  J Endod       Date:  2016-09-09       Impact factor: 4.171

10.  Endodontic Working Length Measurement Using Cone-beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views, Periapical Radiography, and Apex Locator: A Comparative Ex Vivo Study.

Authors:  Funda Yılmaz; Kıvanç Kamburoğlu; Buğra Şenel
Journal:  J Endod       Date:  2017-01       Impact factor: 4.171

View more
  1 in total

1.  The Assessment of Quality of the Root Canal Filling and the Number of Visits Needed for Completing Primary Root Canal Treatment by Operators with Different Experience.

Authors:  Krystyna Pietrzycka; Mateusz Radwanski; Louis Hardan; Rim Bourgi; Davide Mancino; Youssef Haikel; Monika Lukomska-Szymanska
Journal:  Bioengineering (Basel)       Date:  2022-09-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.