Image acquisition optimization of a limited-angle intrafraction verification (LIVE) system for lung radiotherapy.

Yawei Zhang1, Xinchen Deng2, Fang-Fang Yin1,2,3, Lei Ren1,3.   

Abstract

PURPOSE: Limited-angle intrafraction verification (LIVE) has been previously developed for four-dimensional (4D) intrafraction target verification either during arc delivery or between three-dimensional (3D)/IMRT beams. Preliminary studies showed that LIVE can accurately estimate the target volume using kV/MV projections acquired over orthogonal view 30° scan angles. Currently, the LIVE imaging acquisition requires slow gantry rotation and is not clinically optimized. The goal of this study is to optimize the image acquisition parameters of LIVE for different patient respiratory periods and gantry rotation speeds for the effective clinical implementation of the system.
METHOD: Limited-angle intrafraction verification imaging acquisition was optimized using a digital anthropomorphic phantom (XCAT) with simulated respiratory periods varying from 3 s to 6 s and gantry rotation speeds varying from 1°/s to 6°/s. LIVE scanning time was optimized by minimizing the number of respiratory cycles needed for the four-dimensional scan, and imaging dose was optimized by minimizing the number of kV and MV projections needed for four-dimensional estimation. The estimation accuracy was evaluated by calculating both the center-of-mass-shift (COMS) and three-dimensional volume-percentage-difference (VPD) between the tumor in estimated images and the ground truth images. The robustness of LIVE was evaluated with varied respiratory patterns, tumor sizes, and tumor locations in XCAT simulation. A dynamic thoracic phantom (CIRS) was used to further validate the optimized imaging schemes from XCAT study with changes of respiratory patterns, tumor sizes, and imaging scanning directions.
RESULTS: Respiratory periods, gantry rotation speeds, number of respiratory cycles scanned and number of kV/MV projections acquired were all positively correlated with the estimation accuracy of LIVE. Faster gantry rotation speed or longer respiratory period allowed less respiratory cycles to be scanned and less kV/MV projections to be acquired to estimate the target volume accurately. Regarding the scanning time minimization, for patient respiratory periods of 3-4 s, gantry rotation speeds of 1°/s, 2°/s, 3-6°/s required scanning of five, four, and three respiratory cycles, respectively. For patient respiratory periods of 5-6 s, the corresponding respiratory cycles required in the scan changed to four, three, and two cycles, respectively. Regarding the imaging dose minimization, for patient respiratory periods of 3-4 s, gantry rotation speeds of 1°/s, 2-4°/s, 5-6°/s required acquiring of 7, 5, 4 kV and MV projections, respectively. For patient respiratory periods of 5-6 s, 5 kV and 5 MV projections are sufficient for all gantry rotation speeds. The optimized LIVE system was robust against breathing pattern, tumor size and tumor location changes. In the CIRS study, the optimized LIVE system achieved the average center-of-mass-shift (COMS)/volume-percentage-difference (VPD) of 0.3 ± 0.1 mm/7.7 ± 2.0% for the scanning time priority case, 0.2 ± 0.1 mm/6.1 ± 1.2% for the imaging dose priority case, respectively, among all gantry rotation speeds tested. LIVE was robust against different scanning directions investigated.
CONCLUSION: The LIVE system has been preliminarily optimized for different patient respiratory periods and treatment gantry rotation speeds using digital and physical phantoms. The optimized imaging parameters, including number of respiratory cycles scanned and kV/MV projection numbers acquired, provide guidelines for optimizing the scanning time and imaging dose of the LIVE system for its future evaluations and clinical implementations through patient studies.
© 2017 American Association of Physicists in Medicine.

Entities:  

Keywords:  4D-CBCT; free-form deformation; intrafraction verification; limited angle; motion modeling

Mesh:

Year:  2017        PMID: 29091287      PMCID: PMC5774243          DOI: 10.1002/mp.12647

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  24 in total

1.  Fast free-form deformable registration via calculus of variations.

Authors:  Weiguo Lu; Ming-Li Chen; Gustavo H Olivera; Kenneth J Ruchala; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2004-07-21       Impact factor: 3.609

2.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

3.  Respiratory correlated cone beam CT.

Authors:  Jan-Jakob Sonke; Lambert Zijp; Peter Remeijer; Marcel van Herk
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

4.  Linac-integrated 4D cone beam CT: first experimental results.

Authors:  Lars Dietrich; Siri Jetter; Thomas Tücking; Simeon Nill; Uwe Oelfke
Journal:  Phys Med Biol       Date:  2006-05-24       Impact factor: 3.609

5.  Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling.

Authors:  Jun Lu; Thomas M Guerrero; Peter Munro; Andrew Jeung; Pai-Chun M Chi; Peter Balter; X Ronald Zhu; Radhe Mohan; Tinsu Pan
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

Review 6.  Current status and future perspective of flattening filter free photon beams.

Authors:  Dietmar Georg; Tommy Knöös; Brendan McClean
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  A limited-angle intrafraction verification (LIVE) system for radiation therapy.

Authors:  Lei Ren; You Zhang; Fang-Fang Yin
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

8.  Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy.

Authors:  Yawei Zhang; Fang-Fang Yin; You Zhang; Lei Ren
Journal:  Phys Med Biol       Date:  2017-03-24       Impact factor: 3.609

9.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

10.  Automatic registration between reference and on-board digital tomosynthesis images for positioning verification.

Authors:  Lei Ren; Devon J Godfrey; Hui Yan; Q Jackie Wu; Fang-Fang Yin
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

View more
  9 in total

1.  Technical Note: Imaging dose resulting from optimized procedures with limited-angle intrafractional verification system during stereotactic body radiation therapy lung treatment.

Authors:  George X Ding; Yawei Zhang; Lei Ren
Journal:  Med Phys       Date:  2019-04-29       Impact factor: 4.071

2.  Development of realistic multi-contrast textured XCAT (MT-XCAT) phantoms using a dual-discriminator conditional-generative adversarial network (D-CGAN).

Authors:  Yushi Chang; Kyle Lafata; William Paul Segars; Fang-Fang Yin; Lei Ren
Journal:  Phys Med Biol       Date:  2020-03-19       Impact factor: 3.609

3.  Augmentation of CBCT Reconstructed From Under-Sampled Projections Using Deep Learning.

Authors:  Zhuoran Jiang; Yingxuan Chen; Yawei Zhang; Yun Ge; Fang-Fang Yin; Lei Ren
Journal:  IEEE Trans Med Imaging       Date:  2019-04-23       Impact factor: 10.048

4.  Predicting real-time 3D deformation field maps (DFM) based on volumetric cine MRI (VC-MRI) and artificial neural networks for on-board 4D target tracking: a feasibility study.

Authors:  Jonathan Pham; Wendy Harris; Wenzheng Sun; Zi Yang; Fang-Fang Yin; Lei Ren
Journal:  Phys Med Biol       Date:  2019-08-21       Impact factor: 3.609

5.  First clinical retrospective investigation of limited projection CBCT for lung tumor localization in patients receiving SBRT treatment.

Authors:  Yawei Zhang; Fang-Fang Yin; Lei Ren
Journal:  Phys Med Biol       Date:  2019-05-08       Impact factor: 3.609

6.  Real-time Markerless Tracking of Lung Tumors based on 2-D Fluoroscopy Imaging using Convolutional LSTM.

Authors:  Tengya Peng; Zhuoran Jiang; Yushi Chang; Lei Ren
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-11-13

7.  Enhancing digital tomosynthesis (DTS) for lung radiotherapy guidance using patient-specific deep learning model.

Authors:  Zhuoran Jiang; Fang-Fang Yin; Yun Ge; Lei Ren
Journal:  Phys Med Biol       Date:  2021-01-26       Impact factor: 3.609

8.  Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatments.

Authors:  Mark C Korpics; Michelle Rokni; Michael Degnan; Bulent Aydogan; Stanley L Liauw; Gage Redler
Journal:  J Appl Clin Med Phys       Date:  2020-01-24       Impact factor: 2.102

9.  A generative adversarial network (GAN)-based technique for synthesizing realistic respiratory motion in the extended cardiac-torso (XCAT) phantoms.

Authors:  Yushi Chang; Zhuoran Jiang; William Paul Segars; Zeyu Zhang; Kyle Lafata; Jing Cai; Fang-Fang Yin; Lei Ren
Journal:  Phys Med Biol       Date:  2021-05-31       Impact factor: 4.174

  9 in total