Literature DB >> 15357182

Fast free-form deformable registration via calculus of variations.

Weiguo Lu1, Ming-Li Chen, Gustavo H Olivera, Kenneth J Ruchala, Thomas R Mackie.   

Abstract

In this paper, we present a fully automatic, fast and accurate deformable registration technique. This technique deals with free-form deformation. It minimizes an energy functional that combines both similarity and smoothness measures. By using calculus of variations, the minimization problem was represented as a set of nonlinear elliptic partial differential equations (PDEs). A Gauss-Seidel finite difference scheme is used to iteratively solve the PDE. The registration is refined by a multi-resolution approach. The whole process is fully automatic. It takes less than 3 min to register two three-dimensional (3D) image sets of size 256 x 256 x 61 using a single 933 MHz personal computer. Extensive experiments are presented. These experiments include simulations, phantom studies and clinical image studies. Experimental results show that our model and algorithm are suited for registration of temporal images of a deformable body. The registration of inspiration and expiration phases of the lung images shows that the method is able to deal with large deformations. When applied to the daily CT images of a prostate patient, the results show that registration based on iterative refinement of displacement field is appropriate to describe the local deformations in the prostate and the rectum. Similarity measures improved significantly after the registration. The target application of this paper is for radiotherapy treatment planning and evaluation that incorporates internal organ deformation throughout the course of radiation therapy. The registration method could also be equally applied in diagnostic radiology.

Entities:  

Mesh:

Year:  2004        PMID: 15357182     DOI: 10.1088/0031-9155/49/14/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  56 in total

Review 1.  Current progress in adaptive radiation therapy for head and neck cancer.

Authors:  David L Schwartz
Journal:  Curr Oncol Rep       Date:  2012-04       Impact factor: 5.075

2.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model.

Authors:  Agung Hertanto; Qinghui Zhang; Yu-Chi Hu; Oleksandr Dzyubak; Andreas Rimner; Gig S Mageras
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

4.  Analysis of deformable image registration accuracy using computational modeling.

Authors:  Hualiang Zhong; Jinkoo Kim; Indrin J Chetty
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

5.  Application and assessment of a robust elastic motion correction algorithm to dynamic MRI.

Authors:  K-H Herrmann; S Wurdinger; D R Fischer; I Krumbein; M Schmitt; G Hermosillo; K Chaudhuri; A Krishnan; M Salganicoff; W A Kaiser; J R Reichenbach
Journal:  Eur Radiol       Date:  2006-04-13       Impact factor: 5.315

6.  Breathing-synchronized delivery: a potential four-dimensional tomotherapy treatment technique.

Authors:  Tiezhi Zhang; Weiguo Lu; Gustavo H Olivera; Harry Keller; Robert Jeraj; Rafael Manon; Minesh Mehta; Thomas R Mackie; Bhudatt Paliwal
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-06-14       Impact factor: 7.038

7.  Development of a novel post-processing treatment planning platform for 4D radiotherapy.

Authors:  Lan Lin; Chengyu Shi; Yaxi Liu; Gregory Swanson; Nikos Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2008-04

8.  CT to cone-beam CT deformable registration with simultaneous intensity correction.

Authors:  Xin Zhen; Xuejun Gu; Hao Yan; Linghong Zhou; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

9.  An initial investigation of hyperpolarized gas tagging magnetic resonance imaging in evaluating deformable image registration-based lung ventilation.

Authors:  Taoran Cui; G Wilson Miller; John P Mugler; Gordon D Cates; Jaime F Mata; Eduard E de Lange; Qijie Huang; Talissa A Altes; Fang-Fang Yin; Jing Cai
Journal:  Med Phys       Date:  2018-10-23       Impact factor: 4.071

10.  A fast inverse consistent deformable image registration method based on symmetric optical flow computation.

Authors:  Deshan Yang; Hua Li; Daniel A Low; Joseph O Deasy; Issam El Naqa
Journal:  Phys Med Biol       Date:  2008-10-14       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.