Literature DB >> 18383688

Automatic registration between reference and on-board digital tomosynthesis images for positioning verification.

Lei Ren1, Devon J Godfrey, Hui Yan, Q Jackie Wu, Fang-Fang Yin.   

Abstract

The authors developed a hybrid multiresolution rigid-body registration technique to automatically register reference digital tomosynthesis (DTS) images with on-board DTS images to guide patient positioning in radiation therapy. This hybrid registration technique uses a faster but less accurate static method to achieve an initial registration, followed by a slower but more accurate adaptive method to fine tune the registration. A multiresolution scheme is employed in the registration to further improve the registration accuracy, robustness, and efficiency. Normalized mutual information is selected as the criterion for the similarity measure and the downhill simplex method is used as the search engine. This technique was tested using image data both from an anthropomorphic chest phantom and from eight head-and-neck cancer patients. The effects of the scan angle and the region-of-interest (ROI) size on the registration accuracy and robustness were investigated. The necessity of using the adaptive registration method in the hybrid technique was validated by comparing the results of the static method and the hybrid method. With a 44 degrees scan angle and a large ROI covering the entire DTS volume, the average of the registration capture ranges in single-axis simulations was between -31 and +34 deg for rotations and between -89 and +78 mm for translations in the phantom study, and between -38 and +38 deg for rotations and between -58 and +65 mm for translations in the patient study. Decreasing the DTS scan angle from 44 degrees to 22 degrees mainly degraded the registration accuracy and robustness for the out-of-plane rotations. Decreasing the ROI size from the entire DTS volume to the volume surrounding the spinal cord reduced the capture ranges to between -23 and +18 deg for rotations and between -33 and +43 mm for translations in the phantom study, and between -18 and +25 deg for rotations and between -35 and +39 mm for translations in the patient study. Results also showed that the hybrid registration technique had much larger capture ranges than the static method alone in registering the out-of-plane rotations.

Entities:  

Mesh:

Year:  2008        PMID: 18383688     DOI: 10.1118/1.2831903

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Accuracy estimation for projection-to-volume targeting during rotational therapy: a feasibility study.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Digital tomosynthesis for respiratory gated liver treatment: clinical feasibility for daily image guidance.

Authors:  Q Jackie Wu; Jeffrey Meyer; Jessica Fuller; Devon Godfrey; Zhiheng Wang; Junan Zhang; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-18       Impact factor: 7.038

3.  Technical Note: Imaging dose resulting from optimized procedures with limited-angle intrafractional verification system during stereotactic body radiation therapy lung treatment.

Authors:  George X Ding; Yawei Zhang; Lei Ren
Journal:  Med Phys       Date:  2019-04-29       Impact factor: 4.071

Review 4.  Tomosynthesis imaging: at a translational crossroads.

Authors:  James T Dobbins
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

5.  Preliminary clinical evaluation of a 4D-CBCT estimation technique using prior information and limited-angle projections.

Authors:  You Zhang; Fang-Fang Yin; Tinsu Pan; Irina Vergalasova; Lei Ren
Journal:  Radiother Oncol       Date:  2015-03-26       Impact factor: 6.280

6.  Evaluation of respiration-correlated digital tomosynthesis in lung.

Authors:  Joseph Santoro; Sergey Kriminski; D Michael Lovelock; Kenneth Rosenzweig; Hassan Mostafavi; Howard I Amols; Gig S Mageras
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

7.  Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy.

Authors:  Yawei Zhang; Fang-Fang Yin; You Zhang; Lei Ren
Journal:  Phys Med Biol       Date:  2017-03-24       Impact factor: 3.609

8.  Image acquisition optimization of a limited-angle intrafraction verification (LIVE) system for lung radiotherapy.

Authors:  Yawei Zhang; Xinchen Deng; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2017-11-30       Impact factor: 4.071

9.  A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map.

Authors:  Lei Ren; Junan Zhang; Danthai Thongphiew; Devon J Godfrey; Q Jackie Wu; Su-Min Zhou; Fang-Fang Yin
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

10.  Clinical Assessment of 2D/3D Registration Accuracy in 4 Major Anatomic Sites Using On-Board 2D Kilovoltage Images for 6D Patient Setup.

Authors:  Guang Li; T Jonathan Yang; Hugo Furtado; Wolfgang Birkfellner; Åse Ballangrud; Simon N Powell; James Mechalakos
Journal:  Technol Cancer Res Treat       Date:  2014-09-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.