Literature DB >> 22482600

Robust calculation of effective atomic numbers: the Auto-Z(eff) software.

M L Taylor1, R L Smith, F Dossing, R D Franich.   

Abstract

PURPOSE: The most appropriate method of evaluating the effective atomic number necessitates consideration of energy-dependent behavior. Previously, this required quite laborious calculation, which is why many scientists revert to over-simplistic power-law methods. The purpose of this work is to develop user-friendly software for the robust, energy-dependent computation of effective atomic numbers relevant within the context of medical physics, superseding the commonly employed simplistic power law approaches.
METHOD: Visual Basic was used to develop a GUI allowing the straightforward calculation of effective atomic numbers. Photon interaction cross section matrices are constructed for energies spanning 10 keV to 10 GeV and elements Z = 1-100. Coefficients for composite media are constructed via linear additivity of the fractional constituents and contrasted against the precalculated matrices at each energy, thereby associating an effective atomic number through interpolation of adjacent cross section data. Uncertainties are of the order of 1-2%.
RESULTS: Auto-Z(eff) allows rapid (∼0.6 s) calculation of effective atomic numbers for a range of predefined or user-specified media, allowing estimation of radiological properties and comparison of different media (for instance assessment of water equivalence). The accuracy of Auto-Z(eff) has been validated against numerous published theoretical and experimental predictions, demonstrating good agreement. The results also show that commonly employed power-law approaches are inaccurate, even in their intended regime of applicability (i.e., photoelectric regime). Furthermore, comparing the effective atomic numbers of composite materials using power-law approaches even in a relative fashion is shown to be inappropriate.
CONCLUSION: Auto-Z(eff) facilitates easy computation of effective atomic numbers as a function of energy, as well as average and spectral-weighted means. The results are significantly more accurate than normal power-law predictions. The software is freely available to interested readers, who are encouraged to contact the authors.

Entities:  

Mesh:

Year:  2012        PMID: 22482600     DOI: 10.1118/1.3689810

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: comparison of analytic and polyenergetic statistical reconstruction algorithms.

Authors:  Joshua D Evans; Bruce R Whiting; Joseph A O'Sullivan; David G Politte; Paul H Klahr; Yaduo Yu; Jeffrey F Williamson
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

2.  The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging: Implications for CT dosimetry.

Authors:  Kostas Perisinakis; Antonis Tzedakis; Kostas Spanakis; Antonios E Papadakis; Adam Hatzidakis; John Damilakis
Journal:  Eur Radiol       Date:  2017-07-14       Impact factor: 5.315

3.  Phy-X/ZeXTRa: a software for robust calculation of effective atomic numbers for photon, electron, proton, alpha particle, and carbon ion interactions.

Authors:  Ö F Özpolat; B Alım; E Şakar; M Büyükyıldız; M Kurudirek
Journal:  Radiat Environ Biophys       Date:  2020-01-20       Impact factor: 1.925

4.  On the need for comprehensive validation of deformable image registration, investigated with a novel 3-dimensional deformable dosimeter.

Authors:  Titania Juang; Shiva Das; John Adamovics; Ron Benning; Mark Oldham
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-07-23       Impact factor: 7.038

5.  AUTOMATIC DETECTION AND TRACKING OF LONGITUDINAL CHANGES OF MULTIPLE BONE METASTASES FROM DUAL ENERGY CT.

Authors:  Duc Fehr; C Ross Schmidtlein; Sinchun Hwang; Joseph O Deasy; Harini Veeraraghavan
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2016-06-16

6.  Photon buildup factors in some dosimetric materials for heterogeneous radiation sources.

Authors:  Murat Kurudirek
Journal:  Radiat Environ Biophys       Date:  2013-11-28       Impact factor: 1.925

7.  Liquid tissue surrogates for X-ray and CT phantom studies.

Authors:  Paul F FitzGerald; Robert E Colborn; Peter M Edic; Jack W Lambert; Peter J Bonitatibus; Benjamin M Yeh
Journal:  Med Phys       Date:  2017-10-31       Impact factor: 4.071

8.  Influence of magnesium chloride on the dose-response of polyacrylamide-type gel dosimeters.

Authors:  Shin-Ichiro Hayashi; Hiraku Kawamura; Shuji Usui; Takahiro Tominaga
Journal:  Radiol Phys Technol       Date:  2018-09-04

9.  Effective atomic numbers of some tissue substitutes by different methods: A comparative study.

Authors:  Vishwanath P Singh; N M Badiger
Journal:  J Med Phys       Date:  2014-01

10.  Effect of tissue composition on dose distribution in brachytherapy with various photon emitting sources.

Authors:  Mahdi Ghorbani; Fateme Salahshour; Abbas Haghparast; Toktam Ahmadi Moghaddas; Courtney Knaup
Journal:  J Contemp Brachytherapy       Date:  2014-04-03
View more