Literature DB >> 28091875

The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Sabit Melih Ates1, Zeynep Yesil Duymus2, Ipek Caglar2, Bilal Hologlu3.   

Abstract

OBJECTIVE: This in vitro study investigated the marginal fit of metal and zirconia copings before and after veneering on dies with shoulder/chamfer (s/c) finish lines.
MATERIALS AND METHODS: Using CAD/CAM, ten (n = 10) each s/c zirconia (NZ) copings and ten (n = 10) each s/c metal (MM) copings were generated. As controls, ten (n = 10) each s/c zirconia copings were copy-milled (ZZ) and ten (n = 10) each s/c metal copings were cast (CC). The vertical marginal discrepancy of the copings was measured at 20 predefined spots of the circular shoulder and chamfer finish lines in microns (μm) before and after a first and a second veneering firing using a stereomicroscope at ×40 magnification. Data were statistically analyzed, and the comparisons of CAD/CAM-milled (NZ, MM), copy-milled (ZZ), and cast (CC) copings before and after veneering were made at a significance level of p < 0.05.
RESULTS: Gap width at s/c finish lines of ZZ was (91 ± 11/100 ± 28) and increased significantly (109 ± 21/141 ± 18) after the first firing (ZZ1). NZ showed significantly smaller gaps than ZZ (36 ± 6/46 ± 12) and (NZ1) after the first firing (61 ± 16/71 ± 29). Gap widths of CC groups (36 ± 8/25 ± 4) were not significantly different from NZ but were significantly lower after the (CC1) first veneering firing (40 ± 8/42 ± 7). MM copings showed gap values similar to NZ. Second firings did not significantly increase gaps in all groups except ZZ2 of chamfer finish line.
CONCLUSION: Veneering increased the marginal gap width of copings. CLINICAL RELEVANCE: Within the limits of this in vitro study, aesthetic ceramic veneering of CAD/CAM-generated copings caused a statistically significant but tolerable loss of marginal fit precision.

Entities:  

Keywords:  CAD/CAM copings; Esthetic ceramic veneering; Finish line

Mesh:

Substances:

Year:  2017        PMID: 28091875     DOI: 10.1007/s00784-017-2054-x

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  51 in total

1.  Marginal adaptation of fixed prosthodontics: a new in vitro 360-degree external examination procedure.

Authors:  Gianfranco Gassino; Sandro Barone Monfrin; Matteo Scanu; Giuseppe Spina; Giulio Preti
Journal:  Int J Prosthodont       Date:  2004 Mar-Apr       Impact factor: 1.681

Review 2.  A standardized method for determination of crown margin fidelity.

Authors:  J A Sorensen
Journal:  J Prosthet Dent       Date:  1990-07       Impact factor: 3.426

3.  An investigation of dental luting cement solubility as a function of the marginal gap.

Authors:  M S Jacobs; A S Windeler
Journal:  J Prosthet Dent       Date:  1991-03       Impact factor: 3.426

4.  Influence of finish line design on marginal adaptation of electroformed metal-ceramic crowns.

Authors:  Hisaka Shiratsuchi; Futoshi Komine; Yoshiyuki Kakehashi; Hideo Matsumura
Journal:  J Prosthet Dent       Date:  2006-03       Impact factor: 3.426

5.  Comparison of the marginal adaptation of zirconium dioxide crowns in preparations with two different finish lines.

Authors:  Raúl Euán; Oscar Figueras-Álvarez; Josep Cabratosa-Termes; Magí Brufau-de Barberà; Susana Gomes-Azevedo
Journal:  J Prosthodont       Date:  2012-02-28       Impact factor: 2.752

Review 6.  Current status of zirconia-based fixed restorations.

Authors:  Futoshi Komine; Markus B Blatz; Hideo Matsumura
Journal:  J Oral Sci       Date:  2010-12       Impact factor: 1.556

7.  Polycarboxylate cements. Five years' experience in general practice.

Authors:  J W McLean
Journal:  Br Dent J       Date:  1972-01-04       Impact factor: 1.626

8.  Thermal distortion of different materials in crown construction.

Authors:  D Castellani; T Baccetti; C Clauser; U D Bernardini
Journal:  J Prosthet Dent       Date:  1994-10       Impact factor: 3.426

9.  The effect of repeated firings and strength on marginal distortion in two ceramometal systems.

Authors:  W T Buchanan; C W Svare; K A Turner
Journal:  J Prosthet Dent       Date:  1981-05       Impact factor: 3.426

10.  Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses.

Authors:  Wael Att; Futoshi Komine; Thomas Gerds; Jörg Rudolf Strub
Journal:  J Prosthet Dent       Date:  2009-04       Impact factor: 3.426

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.