Literature DB >> 16543022

Influence of finish line design on marginal adaptation of electroformed metal-ceramic crowns.

Hisaka Shiratsuchi1, Futoshi Komine, Yoshiyuki Kakehashi, Hideo Matsumura.   

Abstract

STATEMENT OF PROBLEM: Gold electroformed metal-ceramic restorations have been promoted as alternatives to conventional metal-ceramic restorations. However, little is known about the relationship between tooth preparation design and marginal adaptation for this type of crown.
PURPOSE: This study evaluated the influence of 3 different finish line designs on the marginal adaptation of electroformed metal copings and metal-ceramic crowns.
MATERIAL AND METHODS: Three steel dies were prepared for maxillary central incisor crowns with 3 finish line designs: shoulder, rounded shoulder, and deep chamfer preparations. Eight standardized electroformed metal-ceramic crowns were fabricated for each group. Marginal discrepancies were measured at 60 points for each specimen along the circumferential margin at 4 sites (labial, mesial, lingual, and distal surfaces, with 15 points for each site) before and after firing procedures using a laser microscope. Data among the 3 different groups were statistically analyzed using the Kruskal-Wallis test and the Mann-Whitney U test with the Bonferroni correction. Marginal discrepancies between prefiring and postfiring procedures were evaluated using the Wilcoxon signed-ranks test (alpha = .05).
RESULTS: Significant differences in the marginal discrepancies of electroformed metal copings without porcelain and metal-ceramic crowns were found among all groups. The lowest range of median marginal discrepancy values (P < .05) at 4 sites, both before and after firing, occurred with the deep chamfer preparation (17.64-21.78 microm and 23.96-25.72 microm, respectively). The highest range values were observed in the shoulder preparation (38.13-49.89 microm and 73.87-89.44 microm, respectively). In all situations, the marginal discrepancies of the postfiring procedures were significantly greater (P = .02 or less) than those of the prefiring procedures.
CONCLUSION: Within the limitations of this study, the marginal adaptation of electroformed metal copings or metal-ceramic crowns is affected by finish line design and sequentially diminished by porcelain firing procedures.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16543022     DOI: 10.1016/j.prosdent.2006.01.009

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

Review 1.  Tooth preparation for full-coverage restorations-a literature review.

Authors:  Anke Podhorsky; Peter Rehmann; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

2.  An In-vitro Comparative Stereomicroscopic Analysis and Evaluation of Marginal Accuracy in Porcelain Fused to Metal Copings Fabricated in Two Different Finish Lines Using Variant Die Materials.

Authors:  Priya L Vaswani; Pronob K Sanyal; Siddharth Y Gosavi; Abhijeet R Kore
Journal:  J Clin Diagn Res       Date:  2017-01-01

3.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.