Literature DB >> 15119875

Marginal adaptation of fixed prosthodontics: a new in vitro 360-degree external examination procedure.

Gianfranco Gassino1, Sandro Barone Monfrin, Matteo Scanu, Giuseppe Spina, Giulio Preti.   

Abstract

PURPOSE: This study evaluated the marginal fit of experimental and custom-made fixed prosthetic restorations through a new 360-degree external examination. The minimum number of gap measurements required to produce relevant results for gap analysis was also investigated.
MATERIALS AND METHODS: The marginal fit of six experimental and eight custom-made crowns was observed microscopically by means of a mechanical device, and software was employed to measure the gap. Two crowns, chosen from among the 14 previously evaluated, were reanalyzed to determine the minimum number of gap measurements required to produce significant results for gap analysis.
RESULTS: The precision obtained with the custom-made crowns differed from that of the experimental specimens. The minimum number of measurements required to produce a sample mean value within +/- 5 microm of the mean, calculated over 360 measurements, taking standard error of the means < or = 4 microm, was 18 for experimental and 90 for custom-made crowns, for both equidistant measurement spacing and randomly selected points.
CONCLUSION: Differences in fit between experimental specimens and custom-made ones showed that experimental results might not always be obtained in clinical practice. Within the limitations of the protocol of this study, the minimum number of measurements required to ensure relevant results for gap analysis was 18 for experimental and 90 for custom-made crowns.

Mesh:

Year:  2004        PMID: 15119875

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  14 in total

1.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

2.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

3.  Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns.

Authors:  Hyun-Soon Pak; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-06-30       Impact factor: 1.904

4.  Fit of cobalt-chromium copings fabricated by the selective laser melting technology and casting method: A comparative evaluation using a profilometer.

Authors:  Koosha Gholamrezaei; Fariborz Vafaee; Behzad Fathi Afkari; Farnaz Firouz; Mozhgan Seif
Journal:  Dent Res J (Isfahan)       Date:  2020-05-23

5.  Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study.

Authors:  Pedro Molinero-Mourelle; Rocio Cascos-Sanchez; Burak Yilmaz; Walter Yu Hang Lam; Edmond Ho Nang Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

6.  Evaluation of marginal fit and internal adaptation of zirconia copings fabricated by two CAD - CAM systems: An in vitro study.

Authors:  Balaji N Rajan; Srinivasan Jayaraman; Baburajan Kandhasamy; Ilangkumaran Rajakumaran
Journal:  J Indian Prosthodont Soc       Date:  2015 Apr-Jun

7.  Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques.

Authors:  Mi-Jung Yun; Young-Chan Jeon; Chang-Mo Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

8.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

9.  Effect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD/CAM system.

Authors:  Ji Suk Shim; Jin Sook Lee; Jeong Yol Lee; Yeon Jo Choi; Sang Wan Shin; Jae Jun Ryu
Journal:  J Appl Oral Sci       Date:  2015-10       Impact factor: 2.698

10.  Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study.

Authors:  Sujana Ullattuthodi; Kandathil Phillip Cherian; R Anandkumar; M Sreedevi Nambiar
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.