Literature DB >> 19328277

Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses.

Wael Att1, Futoshi Komine, Thomas Gerds, Jörg Rudolf Strub.   

Abstract

STATEMENT OF PROBLEM: Marginal adaptation is important for the long-term success of dental restorations. Data on the marginal discrepancy of zirconia-based fixed dental prostheses made with different computer-aided design/computer-aided manufacturing technology is needed.
PURPOSE: The purpose of this study was to evaluate the marginal adaptation of different zirconia 3-unit fixed dental prostheses at different fabrication stages and after artificial aging.
MATERIAL AND METHODS: Twenty-four zirconia 3-unit fixed dental prostheses (DCS, Procera, and VITA YZ-Cerec; n=8) were fabricated using different manufacturing systems and conventionally cemented with glass ionomer cement on human teeth. Each group was aged in a masticatory simulator with thermal cycling. The marginal gaps were examined on epoxy replicas for frameworks and for restorations before and after cementation, and after masticatory simulation, at x 250 magnification. Marginal adaptation was assessed using geometric means of the marginal gap values with 95% confidence intervals. Differences between the manufacturing systems and the effect of artificial aging were tested using repeated-measures ANOVA and post hoc paired and unpaired t tests with Bonferroni-Holm correction (alpha=.05).
RESULTS: The geometric mean (95% confidence limits) marginal gap values (mum) for frameworks and for restorations before cementation, after cementation, and after masticatory simulation were, respectively: DCS: 86 (80-93), 86 (83-90), 86 (78-94), and 84 (79-90); Procera: 82 (74-89), 89 (81-97), 89 (84-95), and 88 (82-94); and VITA YZ-Cerec: 64 (57-72), 67 (61-77), 76 (71-82), and 78 (76-80). The repeated-measures ANOVA showed significant group and stage effects (P<.05). Group VITA YZ-Cerec showed significantly smaller marginal gap values than groups DCS and Procera at framework (P<.05) and before-cementation (P<.05) stages. The VITA YZ-Cerec group showed significantly smaller marginal gap values than the Procera group after cementation (P<.05). The marginal gap values between different stages were not significantly different for all groups (P>.05).
CONCLUSIONS: The marginal accuracy of zirconia fixed dental prostheses is influenced by manufacturing technique.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19328277     DOI: 10.1016/S0022-3913(09)60047-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  30 in total

1.  Evaluation of fit of zirconia posterior bridge structures constructed with different scanning methods and preparation angles.

Authors:  Raquel C Oyagüe; M Isabel Sánchez-Jorge; Andrés Sánchez Turrión
Journal:  Odontology       Date:  2010-07-23       Impact factor: 2.634

2.  Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

Authors:  Philipp Kohorst; Janet Junghanns; Marc P Dittmer; Lothar Borchers; Meike Stiesch
Journal:  Clin Oral Investig       Date:  2010-05-22       Impact factor: 3.573

3.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

4.  Adaptation of all-ceramic fixed partial dentures.

Authors:  Márcia Borba; Paulo F Cesar; Jason A Griggs; Álvaro Della Bona
Journal:  Dent Mater       Date:  2011-09-13       Impact factor: 5.304

5.  Marginal fit of 3-unit CAD-CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study.

Authors:  Hüseyin Berkay Belgin; Ediz Kale; Tuncer Burak Özçelik; Burak Yilmaz
Journal:  Odontology       Date:  2021-10-19       Impact factor: 2.634

6.  Comparison of chamfer and deep chamfer preparation designs on the fracture resistance of zirconia core restorations.

Authors:  Ezatollah Jalalian; Roghayeh Rostami; Berivan Atashkar
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-06-14

7.  The effect of preparation design on the fracture resistance of zirconia crown copings (computer associated design/computer associated machine, CAD/CAM system).

Authors:  E Jalalian; B Atashkar; R Rostami
Journal:  J Dent (Tehran)       Date:  2011-09-30

8.  A comparison of marginal fit of glass infiltrated alumina copings fabricated using two different techniques and the effect of firing cycles over them.

Authors:  Hirasankar Bhowmik; Rambhao Parkhedkar
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

9.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

10.  The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Maryam Kohsoltani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.