Literature DB >> 27991453

Low-dose lung cancer screening with photon-counting CT: a feasibility study.

Rolf Symons1, Tyler E Cork, Pooyan Sahbaee, Matthew K Fuld, Steffen Kappler, Les R Folio, David A Bluemke, Amir Pourmorteza.   

Abstract

To evaluate the feasibility of using a whole-body photon-counting detector (PCD) CT scanner for low-dose lung cancer screening compared to a conventional energy integrating detector (EID) system. Radiation dose-matched EID and PCD scans of the COPDGene 2 phantom were acquired at different radiation dose levels (CTDIvol: 3.0, 1.5, and 0.75 mGy) and different tube voltages (120, 100, and 80 kVp). EID and PCD images were compared for quantitative Hounsfield unit (HU) accuracy, noise levels, and contrast-to-noise ratios (CNR) for detection of ground-glass nodules (GGN) and emphysema. The PCD HU accuracy was better than EID for water at all scan parameters. PCD HU stability for lung, GGN and emphysema regions were superior to EID and PCD attenuation values were more reproducible than EID for all scan parameters (all P  <  0.01), while HUs for lung, GGN and emphysema ROIs changed significantly for EID with decreasing dose (all P  <  0.001). PCD showed lower noise levels at the lowest dose setting at 120, 100 and 80 kVp (15.2  ±  0.3 HU versus 15.8  ±  0.2 HU, P  =  0.03; 16.1  ±  0.3 HU versus 18.0  ±  0.4 HU, P  =  0.003; and 16.1  ±  0.3 HU versus 17.9  ±  0.3 HU, P  =  0.001, respectively), resulting in superior CNR for evaluation of GGNs and emphysema at 100 and 80 kVp. PCD provided better HU stability for lung, ground-glass, and emphysema-equivalent foams at lower radiation dose settings with better reproducibility than EID. Additionally, PCD showed up to 10% less noise, and 11% higher CNR at 0.75 mGy for both 100 and 80 kVp. PCD technology may help reduce radiation exposure in lung cancer screening while maintaining diagnostic quality.

Entities:  

Mesh:

Year:  2016        PMID: 27991453      PMCID: PMC5237389          DOI: 10.1088/1361-6560/62/1/202

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

1.  A new look at CT dose measurement: beyond CTDI.

Authors:  Robert L Dixon
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

Review 2.  Radiation exposure at chest CT: a statement of the Fleischner Society.

Authors:  John R Mayo; John Aldrich; Nestor L Muller
Journal:  Radiology       Date:  2003-07       Impact factor: 11.105

3.  Development of a simplified simulation model for performance characterization of a pixellated CdZnTe multimodality imaging system.

Authors:  P Guerra; A Santos; D G Darambara
Journal:  Phys Med Biol       Date:  2008-02-01       Impact factor: 3.609

4.  Quality control in longitudinal studies with computed tomographic densitometry of the lungs.

Authors:  Berend C Stoel; Fred Bode; Alexis Rames; Sherif Soliman; Johan H C Reiber; Jan Stolk
Journal:  Proc Am Thorac Soc       Date:  2008-12-15

5.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

6.  Role of the Quantitative Imaging Biomarker Alliance in optimizing CT for the evaluation of lung cancer screen-detected nodules.

Authors:  James L Mulshine; David S Gierada; Samuel G Armato; Rick S Avila; David F Yankelevitz; Ella A Kazerooni; Michael F McNitt-Gray; Andrew J Buckler; Daniel C Sullivan
Journal:  J Am Coll Radiol       Date:  2015-04       Impact factor: 5.532

7.  To bin or not to bin? The effect of CT system limiting resolution on noise and detectability.

Authors:  Jongduk Baek; Angel R Pineda; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2013-02-11       Impact factor: 3.609

8.  Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging.

Authors:  Jan S Iwanczyk; Einar Nygård; Oded Meirav; Jerry Arenson; William C Barber; Neal E Hartsough; Nail Malakhov; Jan C Wessel
Journal:  IEEE Trans Nucl Sci       Date:  2009       Impact factor: 1.679

9.  Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience.

Authors:  Amir Pourmorteza; Rolf Symons; Veit Sandfort; Marissa Mallek; Matthew K Fuld; Gregory Henderson; Elizabeth C Jones; Ashkan A Malayeri; Les R Folio; David A Bluemke
Journal:  Radiology       Date:  2016-02-03       Impact factor: 11.105

10.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

Authors:  Zhicong Yu; Shuai Leng; Steven M Jorgensen; Zhoubo Li; Ralf Gutjahr; Baiyu Chen; Ahmed F Halaweish; Steffen Kappler; Lifeng Yu; Erik L Ritman; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-02-02       Impact factor: 3.609

View more
  25 in total

Review 1.  Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology.

Authors:  Shuai Leng; Michael Bruesewitz; Shengzhen Tao; Kishore Rajendran; Ahmed F Halaweish; Norbert G Campeau; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiographics       Date:  2019 May-Jun       Impact factor: 5.333

2.  150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images.

Authors:  Shuai Leng; Kishore Rajendran; Hao Gong; Wei Zhou; Ahmed F Halaweish; Andre Henning; Steffen Kappler; Matthias Baer; Joel G Fletcher; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2018-11       Impact factor: 6.016

3.  Photon-counting CT for simultaneous imaging of multiple contrast agents in the abdomen: An in vivo study.

Authors:  Rolf Symons; Bernhard Krauss; Pooyan Sahbaee; Tyler E Cork; Manu N Lakshmanan; David A Bluemke; Amir Pourmorteza
Journal:  Med Phys       Date:  2017-08-20       Impact factor: 4.071

4.  Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans.

Authors:  Rolf Symons; Amir Pourmorteza; Veit Sandfort; Mark A Ahlman; Tracy Cropper; Marissa Mallek; Steffen Kappler; Stefan Ulzheimer; Mahadevappa Mahesh; Elizabeth C Jones; Ashkan A Malayeri; Les R Folio; David A Bluemke
Journal:  Radiology       Date:  2017-07-28       Impact factor: 11.105

5.  Measuring arterial wall perfusion using photon-counting computed tomography (CT): improving CT number accuracy of artery wall using image deconvolution.

Authors:  Kishore Rajendran; Shuai Leng; Steven M Jorgensen; Jill L Anderson; Ahmed F Halaweish; Dilbar Abdurakhimova; Erik L Ritman; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-12-08

6.  Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning.

Authors:  Joakim da Silva; Fredrik Grönberg; Björn Cederström; Mats Persson; Martin Sjölin; Zlatan Alagic; Robert Bujila; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-15

7.  Dual-contrast agent photon-counting computed tomography of the heart: initial experience.

Authors:  Rolf Symons; Tyler E Cork; Manu N Lakshmanan; Robert Evers; Cynthia Davies-Venn; Kelly A Rice; Marvin L Thomas; Chia-Ying Liu; Steffen Kappler; Stefan Ulzheimer; Veit Sandfort; David A Bluemke; Amir Pourmorteza
Journal:  Int J Cardiovasc Imaging       Date:  2017-03-13       Impact factor: 2.357

8.  Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.

Authors:  Rolf Symons; Daniel S Reich; Mohammadhadi Bagheri; Tyler E Cork; Bernhard Krauss; Stefan Ulzheimer; Steffen Kappler; David A Bluemke; Amir Pourmorteza
Journal:  Invest Radiol       Date:  2018-03       Impact factor: 6.016

9.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets.

Authors:  Shuai Leng; Wei Zhou; Zhicong Yu; Ahmed Halaweish; Bernhard Krauss; Bernhard Schmidt; Lifeng Yu; Steffen Kappler; Cynthia McCollough
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

10.  Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT.

Authors:  Jayasai R Rajagopal; Faraz Farhadi; Justin Solomon; Pooyan Sahbaee; Babak Saboury; William F Pritchard; Elizabeth C Jones; Ehsan Samei
Journal:  Acad Radiol       Date:  2020-08-24       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.