Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans.

Rolf Symons1, Amir Pourmorteza1, Veit Sandfort1, Mark A Ahlman1, Tracy Cropper1, Marissa Mallek1, Steffen Kappler1, Stefan Ulzheimer1, Mahadevappa Mahesh1, Elizabeth C Jones1, Ashkan A Malayeri1, Les R Folio1, David A Bluemke1.   

Abstract

Purpose To investigate whether photon-counting detector (PCD) technology can improve dose-reduced chest computed tomography (CT) image quality compared with that attained with conventional energy-integrating detector (EID) technology in vivo. Materials and Methods This was a HIPAA-compliant institutional review board-approved study, with informed consent from patients. Dose-reduced spiral unenhanced lung EID and PCD CT examinations were performed in 30 asymptomatic volunteers in accordance with manufacturer-recommended guidelines for CT lung cancer screening (120-kVp tube voltage, 20-mAs reference tube current-time product for both detectors). Quantitative analysis of images included measurement of mean attenuation, noise power spectrum (NPS), and lung nodule contrast-to-noise ratio (CNR). Images were qualitatively analyzed by three radiologists blinded to detector type. Reproducibility was assessed with the intraclass correlation coefficient (ICC). McNemar, paired t, and Wilcoxon signed-rank tests were used to compare image quality. Results Thirty study subjects were evaluated (mean age, 55.0 years ± 8.7 [standard deviation]; 14 men). Of these patients, 10 had a normal body mass index (BMI) (BMI range, 18.5-24.9 kg/m2; group 1), 10 were overweight (BMI range, 25.0-29.9 kg/m2; group 2), and 10 were obese (BMI ≥30.0 kg/m2, group 3). PCD diagnostic quality was higher than EID diagnostic quality (P = .016, P = .016, and P = .013 for readers 1, 2, and 3, respectively), with significantly better NPS and image quality scores for lung, soft tissue, and bone and with fewer beam-hardening artifacts (all P < .001). Image noise was significantly lower for PCD images in all BMI groups (P < .001 for groups 1 and 3, P < .01 for group 2), with higher CNR for lung nodule detection (12.1 ± 1.7 vs 10.0 ± 1.8, P < .001). Inter- and intrareader reproducibility were good (all ICC > 0.800). Conclusion Initial human experience with dose-reduced PCD chest CT demonstrated lower image noise compared with conventional EID CT, with better diagnostic quality and lung nodule CNR. © RSNA, 2017 Online supplemental material is available for this article.

Entities:  

Mesh:

Year:  2017        PMID: 28753389      PMCID: PMC5708286          DOI: 10.1148/radiol.2017162587

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  22 in total

1.  A new look at CT dose measurement: beyond CTDI.

Authors:  Robert L Dixon
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

2.  Fleischner Society: glossary of terms for thoracic imaging.

Authors:  David M Hansell; Alexander A Bankier; Heber MacMahon; Theresa C McLoud; Nestor L Müller; Jacques Remy
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

3.  Development of a simplified simulation model for performance characterization of a pixellated CdZnTe multimodality imaging system.

Authors:  P Guerra; A Santos; D G Darambara
Journal:  Phys Med Biol       Date:  2008-02-01       Impact factor: 3.609

4.  Quality control in longitudinal studies with computed tomographic densitometry of the lungs.

Authors:  Berend C Stoel; Fred Bode; Alexis Rames; Sherif Soliman; Johan H C Reiber; Jan Stolk
Journal:  Proc Am Thorac Soc       Date:  2008-12-15

Review 5.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

6.  Spatio-energetic cross talk in photon counting detectors: Detector model and correlated Poisson data generator.

Authors:  Katsuyuki Taguchi; Christoph Polster; Okkyun Lee; Karl Stierstorfer; Steffen Kappler
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

7.  Photon-counting CT for simultaneous imaging of multiple contrast agents in the abdomen: An in vivo study.

Authors:  Rolf Symons; Bernhard Krauss; Pooyan Sahbaee; Tyler E Cork; Manu N Lakshmanan; David A Bluemke; Amir Pourmorteza
Journal:  Med Phys       Date:  2017-08-20       Impact factor: 4.071

8.  A simple approach to measure computed tomography (CT) modulation transfer function (MTF) and noise-power spectrum (NPS) using the American College of Radiology (ACR) accreditation phantom.

Authors:  Saul N Friedman; George S K Fung; Jeffrey H Siewerdsen; Benjamin M W Tsui
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

9.  Electronic noise in CT detectors: Impact on image noise and artifacts.

Authors:  Xinhui Duan; Jia Wang; Shuai Leng; Bernhard Schmidt; Thomas Allmendinger; Katharine Grant; Thomas Flohr; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2013-10       Impact factor: 3.959

10.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

View more
  27 in total

1.  Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study.

Authors:  W Zhou; J I Lane; M L Carlson; M R Bruesewitz; R J Witte; K K Koeller; L J Eckel; R E Carter; C H McCollough; S Leng
Journal:  AJNR Am J Neuroradiol       Date:  2018-08-09       Impact factor: 3.825

2.  Dose reduction in abdominal CT: The road to submillisievert imaging.

Authors:  Alexander A Fingerle; Peter B Noël
Journal:  Eur Radiol       Date:  2018-04-10       Impact factor: 5.315

3.  Photon-counting computed tomography of lanthanide contrast agents with a high-flux 330-μm-pitch cadmium zinc telluride detector in a table-top system.

Authors:  Chelsea A S Dunning; Jericho O'Connell; Spencer M Robinson; Kevin J Murphy; Adriaan L Frencken; Frank C J M van Veggel; Kris Iniewski; Magdalena Bazalova-Carter
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-15

4.  High-Resolution Chest Computed Tomography Imaging of the Lungs: Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography.

Authors:  David J Bartlett; Chi Wan Koo; Brian J Bartholmai; Kishore Rajendran; Jayse M Weaver; Ahmed F Halaweish; Shuai Leng; Cynthia H McCollough; Joel G Fletcher
Journal:  Invest Radiol       Date:  2019-03       Impact factor: 6.016

5.  Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.

Authors:  Rolf Symons; Daniel S Reich; Mohammadhadi Bagheri; Tyler E Cork; Bernhard Krauss; Stefan Ulzheimer; Steffen Kappler; David A Bluemke; Amir Pourmorteza
Journal:  Invest Radiol       Date:  2018-03       Impact factor: 6.016

6.  Development of a scanner-specific simulation framework for photon-counting computed tomography.

Authors:  Ehsan Abadi; Brian Harrawood; Jayasai R Rajagopal; Shobhit Sharma; Anuj Kapadia; William Paul Segars; Karl Stierstorfer; Martin Sedlmair; Elizabeth Jones; Ehsan Samei
Journal:  Biomed Phys Eng Express       Date:  2019-08-09

7.  Impacts of photon counting CT to maximum intensity projection (MIP) images of cerebral CT angiography: theoretical and experimental studies.

Authors:  Evan Cary Harvey; Mang Feng; Xu Ji; Ran Zhang; Yinsheng Li; Guang-Hong Chen; Ke Li
Journal:  Phys Med Biol       Date:  2019-09-19       Impact factor: 3.609

8.  Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT.

Authors:  Jayasai R Rajagopal; Faraz Farhadi; Justin Solomon; Pooyan Sahbaee; Babak Saboury; William F Pritchard; Elizabeth C Jones; Ehsan Samei
Journal:  Acad Radiol       Date:  2020-08-24       Impact factor: 3.173

9.  Detection and Characterization of Renal Stones by Using Photon-Counting-based CT.

Authors:  Roy P Marcus; Joel G Fletcher; Andrea Ferrero; Shuai Leng; Ahmed F Halaweish; Ralf Gutjahr; Terri J Vrtiska; Mike L Wells; Felicity T Enders; Cynthia H McCollough
Journal:  Radiology       Date:  2018-08-07       Impact factor: 11.105

10.  Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment.

Authors:  A Pourmorteza; R Symons; D S Reich; M Bagheri; T E Cork; S Kappler; S Ulzheimer; D A Bluemke
Journal:  AJNR Am J Neuroradiol       Date:  2017-10-05       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.