Literature DB >> 12832569

Radiation exposure at chest CT: a statement of the Fleischner Society.

John R Mayo1, John Aldrich, Nestor L Muller.   

Abstract

The introduction of helical single-detector row computed tomography (CT) and, more recently, multi-detector row CT has greatly increased the clinical indications for CT. Correspondingly, CT examinations now account for greater than one-half of the radiation dose due to medical procedures in the population of North America. The level of CT radiation dose, especially in the pediatric population, is of concern to radiologists, medical physicists, government regulators, and the media. This review addresses this problem with particular reference to radiation dose in chest CT. Specifically it outlines the topics of measurement units used to quantify radiation exposure, factors affecting CT scanner dose efficiency, scanner settings that determine the administered radiation dose, and radiation dose reduction in chest CT. A table of reference dose values is provided. Given the wide variation documented in chest CT radiation exposure, the authors suggest that reference standards be promoted to minimize excessive CT radiation exposure. In addition, further research into the complex relationship between radiation exposure, image quality, and diagnostic accuracy should be encouraged in order to establish the minimum radiation dose necessary to provide adequate diagnostic information for standard clinical questions.

Mesh:

Year:  2003        PMID: 12832569     DOI: 10.1148/radiol.2281020874

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  81 in total

Review 1.  Quantitative pulmonary imaging using computed tomography and magnetic resonance imaging.

Authors:  George R Washko; Grace Parraga; Harvey O Coxson
Journal:  Respirology       Date:  2012-04       Impact factor: 6.424

2.  Evaluation of coronary artery in-stent restenosis with prospectively ECG-triggered axial CT angiography versus retrospective technique: a phantom study.

Authors:  W-J Yang; Z-L Pan; H Zhang; L-F Pang; Y Guo; K-M Chen
Journal:  Radiol Med       Date:  2010-10-06       Impact factor: 3.469

3.  A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference.

Authors:  Ji Yung Choo; Ki Yeol Lee; Ami Yu; Je-Hyeong Kim; Seung Heon Lee; Jung Won Choi; Eun-Young Kang; Yu Whan Oh
Journal:  Eur Radiol       Date:  2015-12-11       Impact factor: 5.315

Review 4.  [MRI of pulmonary embolism].

Authors:  C Fink; S Thieme; S Ley; D Clevert; M F Reiser; H-U Kauczor; S O Schoenberg
Journal:  Radiologe       Date:  2007-08       Impact factor: 0.635

5.  Computed tomography dose and variability of airway dimension measurements: how low can we go?

Authors:  Pim A de Jong; Frederick R Long; Yasutaka Nakano
Journal:  Pediatr Radiol       Date:  2006-08-10

6.  The value of thoracic computed tomography scans in clinical diagnosis: a prospective study.

Authors:  Mark O Turner; John R Mayo; Nestor L Müller; Michael Schulzer; J Mark FitzGerald
Journal:  Can Respir J       Date:  2006-09       Impact factor: 2.409

Review 7.  Radiation dose-reduction strategies for neuroradiology CT protocols.

Authors:  A B Smith; W P Dillon; R Gould; M Wintermark
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

8.  Chest radiography in intensive care: an irreplaceable survey?

Authors:  V Palazzetti; E Gasparri; C Gambini; S Sollazzo; S Saric; L Salvolini; A Giovagnoni
Journal:  Radiol Med       Date:  2012-10-22       Impact factor: 3.469

9.  Thymic neuroendocrine tumors in multiple endocrine neoplasia type 1: a comparative study on 21 cases among a series of 761 MEN1 from the GTE (Groupe des Tumeurs Endocrines).

Authors:  Pierre Goudet; Arnaud Murat; Catherine Cardot-Bauters; Philippe Emy; Eric Baudin; Hélène du Boullay Choplin; Yves Chapuis; Jean-Louis Kraimps; Jean-Louis Sadoul; Antoine Tabarin; Bruno Vergès; Bruno Carnaille; Patricia Niccoli-Sire; Annie Costa; Alain Calender
Journal:  World J Surg       Date:  2009-06       Impact factor: 3.352

10.  Lung ultrasound in the diagnosis of stroke-associated pneumonia.

Authors:  Chiara Busti; Giancarlo Agnelli; Michele Duranti; Cristina Orlandi; Maura Marcucci; Maurizio Paciaroni
Journal:  Intern Emerg Med       Date:  2012-07-31       Impact factor: 3.397

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.