Influence of Operator's Experience on the Shaping Ability of Protaper Universal and Waveone Systems: A Comparative Study on Simulated Root Canals.

Giuseppe Troiano1, Mario Dioguardi1, Armando Cocco1, Giovanni Giannatempo1, Luigi Laino1, Domenico Ciavarella1, Elio Berutti2, Lorenzo Lo Muzio1.   

Abstract

OBJECTIVE: To assess the influence of operator experience on: shaping and centering ability, mean preparation time and presence of canal aberrations of ProTaper Universal and WaveOne systems on simulated root canals.
MATERIALS AND METHODS: Sixty S-shaped canals in resin blocks were assigned to four groups (n=15 for each group). Group1 (Experienced operator, ProTaper), Group2 (Experienced operator, WaveOne), Group3 (Inexperienced operator, ProTaper), Group4 (Inexperienced operator, WaveOne). Photographic method was used to record pre- and post-instrumentations images. After superimposition, it has been evaluated presence of canal aberrations and differences in shaping and centering ability between groups.
RESULTS: WaveOne system produced a lower amount of canal aberrations both in the hand of expert than inexpert operators. However, a WaveOne instrument breakage occurred in the hands of an inexperienced operator. No differences have been found in the evaluation of shaping ability with both systematics. Operator's experience doesn't influence the shaping ability of ProTaper and WaveOne systems.
CONCLUSION: Experience factor could influence the centering ability in the use of both the systematics. However, WaveOne Primary reduce the mean preparation time and the presence of canal aberrations.

Entities:  

Keywords:  Centering ability; Endodontic; ProTaper; Reciprocating; Shaping ability; WaveOne

Year:  2016        PMID: 27843508      PMCID: PMC5074003          DOI: 10.2174/1874210601610010546

Source DB:  PubMed          Journal:  Open Dent J        ISSN: 1874-2106


INTRODUCTION

A correct shaping is one of the most important goal to achieve success in endodontic treatment. Ni-Ti instruments allowed a cutting easier way to prepare root canals and thanks to their elastic properties allow a reduction of the mean time of shaping and an improvement of the centering ability [1]. Ni-Ti systematic differ for: taper, tip size, blade pitch, type of rotary motion and instruments number [2]. The use of largely Ni-Ti rotary systems is based on Crown-Down concepts that allow a reduction of intracanal friction and should decrease the risk of intracanal fracture [3], this is also due to the presence of non cutting tip that reduce the possibility of taper lock [4]. The ProTaper Universal system (PTU) (Dentsply Maillefer, Ballaigues, Switzerland) involves the use of instruments having a convex triangular cross-sectional design with multiple taper size [5]. The first two instruments (shaping set) primarily shape the coronal and middle part of the canal, while the last tools (finishing set) work in the apical region [6]. The need to reduce time of shaping combined with a higher ease of use has led to the development of single file systems. These files are manufactured with M-Wire alloy which allows a better flexibility and improve resistance to cyclic fatigue [7]. Besides, this system involves the use with reciprocating motion, which decreases instrument stress and apical debris [8]. However, data on apical debris contrasting with results of other studies, which suggest that increase (correct the ward to increase) of apical debris was caused by the counterclockwise movement [9]. WaveOne is a single file system with a modified convex triangular cross-section at the tip end and a convex triangular cross-section, similar to ProTaper, at the coronal end [10]. The purpose of this study was to assess the influence of operator experience on the presence of aberrations and shaping ability when using ProTaper (multi instruments system) and WaveOne (single file system) in S-shape simulated root canals.

MATERIALS AND METHODS

Shaping Procedures

A number of 15, S-shaped ISO 15 0.02 taper endo training blocks (Dentsply Maillefer), were assigned to each group for a total of 60. Although these samples presenting qualitative differences with teeth, they represent a valid tool for in vitro evaluations because they permit an easier standardization and comparison of different shaping methods [11]. Groups 1 and 2 were shaped by an expert operator, postgraduate in endodontics with more of ten years experience, while, an inexperienced operator, a student in the last year of study, with poor endodontic experience performed shaping in Groups 3-4 [12]. A first survey of canals has been made with # 10 K file to assess the working length (WL), after that the glide path was achieved with PathFile 1, 2, and 3 (Dentsply Maillefer) at the WL. Subsequently, samples in groups 1 and 3 were shaped with ProTaper system (S1-S2-F1-F2), whilst groups 2 and 4 were shaped with WaveOne Primary reciprocating file in order to have in each method a tip size of 0.25 mm [13]. A dedicated shaping program has been used for the utilization of each single file with parameters suggested by manufacturers (X-Smart; Dentsply Maillefer). Before use, each instrument was lubricated with Glyde (Dentsply Maillefer), whilst a rinse with 2.5% NaOCl was made after the use of each instrument. A set of new instruments was used for the shaping of each resin block. The preparation time has been recorded for each simulated canal from the end of glide path to the reaching the WL with the final file.

Data Recording

Pre- and post- instrumentation images were recorded with a digital camera (Canon 1100D, Tokyo Japan, ISO 100, f 18, 1/60 s) at a fixed points and magnification. To decrease movements during shooting photo has been used an at distance activation command, and the camera was mounted on a stable support. Furthermore, reference points were placed on the specimens to facilitate the subsequent superimposition. This last one has been carried out with the use of dedicated imaging software (GIMP 2.8, Free Software Foundation, Boston, USA). After that, superimposed images have been loaded on Autocad 2013 (Autodesk Inc, San Rafael, USA) software to perform shaping analysis (Fig. ). Amount of resin removed from the inner and outer aspect of the canal has been recorded at 1 to 9 mm (1 mm for each step) from the apex for a total of 18 measurements for each canal (Fig. ). All measurements were carried out at a right angle to the mean axis of the pre-instrumental canal [14]. Centering ability was evaluated at each point subtracting the amount of resin removed from the inner part to that removed from the outer aspect of the canal. While width shaping has been calculated adding these two measurements [15].

Canal Aberrations and Instrument Fracture

Presence of canal aberrations has been evaluated according to the parameters of Thompson and Dummer [16] by a third operator blinded for this study. Thanks to photographic evaluation has been recorded the possible presence of: elbow, apical zip, perforation and danger zone. In addition, we evaluated if experience factor could increase the rate of instrument fracture when using ProTaper or WaveOne systems.

Statistical Analysis

Data have been analyzed using GraphPad Prism software 6.00 (GraphPad Prism Software, San Diego, CA,USA) by an expert in statistical analysis. Statistical significance between different groups was determined by one-way ANOVA and Tukey test.

RESULTS

Preparation Time

The mean preparation time, employed with the use of the two systematic, for each group has been reported in Table . According with these data, WaveOne system determines a reduction of time of shaping both in expert than in inexpert operator compared with ProTaper system.

Presence of Canal Aberrations and Instrument Failures

The results of canal aberrations are summarized in Table . ProTaper groups showed a higher tendency to produce canal aberrations than WaveOne groups. However, an event of instrument breakage was found only in Group 4, while this event has not been reported in the remaining groups.

Amount of Resin Removed

The amount of resin removed from the interior and exterior wall of the channel was measured from 1 to 9 millimeters to the apex and is summarized in Table . Adding, the internal and external measurements to each millimeter, the total amount of resin removed was obtained at each measurement point (Fig. ). From the graph it can see that the experienced operator tends to shape more the apical area (1 to 3 mm from the apex) respect to the inexpert operator. The difference is significant regarding use of systematic WaveOne (p < 0,05)

Centering Ability

The centering ability was evaluated between groups and reported in Fig. (). The difference was statistically significant only at levels 3 and 4 from the apex. At these levels the experience factor has allowed to obtain a better centering with both systematic. We noticed that WaveOne got skill centering best of systematic ProTaper, but the differences are not significant report in the apical part of the canal.

DISCUSSION

The shaping of the root canal system is one of the most important steps in endodontics, in order to create a path suitable for the subsequent action of irrigants. Niti alloy allows a simpler and easier action thanks to its elastic properties. A lot of instrumentation techniques have been developed providing clinicians various options for a correct root canal shaping. These systems differ among themselves for: cutting section, instruments' number, subtype of Niti alloy and dynamics of motion. However poor studies have evaluated the influence of operator experience on the shaping ability of different Niti systems [17]. For this reason we performed a comparison of a multistep rotational system (ProTaper) with a single-file reciprocating system (WaveOne) in the hands of operators with different experience. In this study we evaluated the shaping and centering ability, presence of canal aberrations and time of preparation on simulated root canals. Simulated root canals allow a direct visualization and represent a valid tool for comparative analysis [11]. Results of our analysis revealed a reduction of time of preparation with WaveOne single file both in expert and inexpert operator. In addition, single file reciprocating system strongly reduce the possibility of canal aberrations (Group 3 vs Group 4), these data accord to others authors about a lower presence of aberrations and cracks using reciprocating than rotational systems [18]. However, one instrument breakage occurred in the WaveOne inexpert group, this is in contrast with the results of previously studies in which no instrument breakage occurred with the use of reciprocating WaveOne file [19]. Analysis on centering ability was performed after photographic superimposition, our data showed no differences between groups with the same experience factor rate. These results accord to previously study in which no differences have been found between centering abilities of ProTaper and WaveOne systems [20]. However, comparing these parameters with Tukey test, we found a statistically difference in centering ability (p < 0,05) between groups 2 and 4 at 3-4 mm from the apex. Evaluating the amount of resin removed showed no difference in the shaping ability with ProTaper System suggesting no influence of operator experience in the management of this systematic. In the comparison of WaveOne groups with different experience statistically significant difference has been found in the use of this system from 4 to 9 mm. Data revealed that inexperienced operator tends to less prepare the apical portion of the canal (1 to 3 mm), because of a worse respect of WL, while he performed an higher amount of shaping in the coronal aspect (7 to 9 mm), probably due to execution of brushing movements.

CONCLUSION

Under the conditions and limitations of this study, operator’s experience doesn't influence the shaping ability of ProTaper and WaveOne systems. Experience factor could influence the centering ability in the use of both the systematics at the apical portion (3-4 mm). However, WaveOne system reduced the mean preparation time and the presence of canal aberrations. In addition, instrument breakage might occurred as a result of improper use of WaveOne file in the hands of an inexperienced operator, for these reasons, performing a glyde-path could help clinicians to reduce iatrogenic errors.
Table 1

Mean preparation time have been expressed as mean +/- standard deviations. Data are expressed in seconds.

MeanSD
Group 1228 s35.8 s
Group 244.8 s4.7 s
Group 3405.4 s47.9 s
Group 4110 s36.6 s
Table 2

Incidence of canal aberrations on S-shape simulated root canals.

Aberration tipeApical ZipElbowLedgesPerforationDanger zoneInstrument Breakage
Group 121----
Group 2------
Group 33211--
Group 411---1
Table 3

Analysis of the amount resin removed from the inner and outer aspect of the canal at nine points level from the apex. (*P < 0.05; **P < 0.01; ***P < 0.001).

  
Inner canal side (mm from the apex)Outer canal side (mm from the apex)
123456789123456789
Group 1
Mean0.1050.2600.3100.2350.1430.1150.1420.2120.2810.0960.0820.0780.1610.3230.4460.4480.3350.277
SD0.0620.0750.0660.0320.0270.0270.0440.0470.0370.0510.0160.0250.0260.0790.0340.0660.0610.048
Group 2
Mean0.1210.2410.2900.2380.1870.1900.2260.2860.3140.1320.1170.1130.1790.3470.4410.4320.3870.329
SD0.0310.0460.0530.0450.0680.1030.1060.0890.0680.0340.0470.0480.0360.0620.1320.1290.1080.082
Group 3
Mean0.0750.2190.3110.2480.1340.1070.1580.2220.2900.1260.0660.060.1320.3420.4450.4160.3250.237
SD0.0420.0870.0420.0390.0340.0290.0290.0290.0270.0240.0230.0160.0470.0380.0470.0450.0240.017
Group 4
Mean0.0670.0230.3280.2580.1630.1420.1960.2750.3300.1360.0980.0670.1120.3090.4220.4080.3350.265
SD0.0340.0600.0670.0460.0490.0480.0710.0690.0530.0340.0160.0130.0240.0470.0710.0820.0790.068
P-value*****--******************----***
  20 in total

1.  Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: Part 1.

Authors:  S A Thompson; P M Dummer
Journal:  Int Endod J       Date:  2000-05       Impact factor: 5.264

2.  Progressive versus constant tapered shaft design using NiTi rotary instruments.

Authors:  L Bergmans; J Van Cleynenbreugel; M Beullens; M Wevers; B Van Meerbeek; P Lambrechts
Journal:  Int Endod J       Date:  2003-04       Impact factor: 5.264

3.  Shaping ability of progressive versus constant taper instruments in simulated root canals.

Authors:  G B Yang; X D Zhou; H Zhang; H K Wu
Journal:  Int Endod J       Date:  2006-10       Impact factor: 5.264

4.  Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

Authors:  Sebastian Bürklein; Edgar Schäfer
Journal:  J Endod       Date:  2012-04-06       Impact factor: 4.171

5.  A micro-computed tomography-based comparison of the canal transportation and centering ability of ProTaper Universal rotary and WaveOne reciprocating files.

Authors:  Blake McRay; Timothy C Cox; Nestor Cohenca; James D Johnson; Avina Paranjpe
Journal:  Quintessence Int       Date:  2014-02       Impact factor: 1.677

6.  Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments.

Authors:  E Pedullà; F Lo Savio; S Boninelli; G Plotino; N M Grande; E Rapisarda; G La Rosa
Journal:  Int Endod J       Date:  2014-11-18       Impact factor: 5.264

Review 7.  A review of instrumentation kinematics of engine-driven nickel-titanium instruments.

Authors:  I D Çapar; H Arslan
Journal:  Int Endod J       Date:  2015-02-18       Impact factor: 5.264

8.  Validated finite element analyses of WaveOne Endodontic Instruments: a comparison between M-Wire and NiTi alloys.

Authors:  N Bonessio; E S J Pereira; G Lomiento; A Arias; M G A Bahia; V T L Buono; O A Peters
Journal:  Int Endod J       Date:  2014-07-12       Impact factor: 5.264

9.  The validity of simulated root canals for the investigation of the prepared root canal shape.

Authors:  K C Lim; J Webber
Journal:  Int Endod J       Date:  1985-10       Impact factor: 5.264

10.  Canal shaping with WaveOne reciprocating files: influence of operator experience on instrument breakage and canal preparation time.

Authors:  Luigi Generali; Elena Righi; Maria Vittoria Todesca; Ugo Consolo
Journal:  Odontology       Date:  2013-06-28       Impact factor: 2.634

View more
  10 in total

1.  Both operator and heat treatment determine the centring ability of Reciproc® files in vitro.

Authors:  N Hofmann
Journal:  Clin Oral Investig       Date:  2018-05-12       Impact factor: 3.573

2.  Simulated root canals preparation time, comparing ProTaper Next and WaveOne Gold systems, performed by an undergraduate student.

Authors:  Inês Conceição; Inês Ferreira; Ana-Cristina Braga; Irene Pina-Vaz
Journal:  J Clin Exp Dent       Date:  2020-08-01

3.  Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals.

Authors:  Giuseppe Troiano; Mario Dioguardi; Armando Cocco; Michele Giuliani; Cristiano Fabiani; Alfonso D'Alessandro; Domenico Ciavarella; Lorenzo Lo Muzio
Journal:  ScientificWorldJournal       Date:  2016-12-08

4.  Increase in [corrected] the glyde path diameter improves the centering ability of F6 Skytaper.

Authors:  Giuseppe Troiano; Mario Dioguardi; Armando Cocco; Khrystyna Zhurakivska; Domenico Ciavarella; Lorenzo Lo Muzio
Journal:  Eur J Dent       Date:  2018 Jan-Mar

5.  Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments.

Authors:  Gianluca Gambarini; Gabriele Miccoli; Marco Seracchiani; Tatyana Khrenova; Orlando Donfrancesco; Maurilio D'Angelo; Massimo Galli; Dario Di Nardo; Luca Testarelli
Journal:  Materials (Basel)       Date:  2019-08-08       Impact factor: 3.623

6.  Reciproc Endodontic File Surface Defects After Single Use: An SEM Analysis.

Authors:  Mohammed Howait
Journal:  J Int Soc Prev Community Dent       Date:  2021-01-30

7.  Dynamic torque analysis of rotary and reciprocating instruments during root canal instrumentation in simulated canals by an endodontist or a general dentist.

Authors:  Marco Antonio Z Loureiro; Giampiero Rossi-Fedele; Octavio G Amezcua; Paulo O Carmo Souza; Julio A Silva; Carlos Estrela; Daniel A Decurcio
Journal:  J Conserv Dent       Date:  2020-11-05

Review 8.  Endodontic irrigants: Different methods to improve efficacy and related problems.

Authors:  Mario Dioguardi; Giovanni Di Gioia; Gaetano Illuzzi; Enrica Laneve; Armando Cocco; Giuseppe Troiano
Journal:  Eur J Dent       Date:  2018 Jul-Sep

Review 9.  Inspection of the Microbiota in Endodontic Lesions.

Authors:  Mario Dioguardi; Giovanni Di Gioia; Gaetano Illuzzi; Claudia Arena; Vito Carlo Alberto Caponio; Giorgia Apollonia Caloro; Khrystyna Zhurakivska; Iolanda Adipietro; Giuseppe Troiano; Lorenzo Lo Muzio
Journal:  Dent J (Basel)       Date:  2019-05-01

Review 10.  Management of Instrument Sterilization Workflow in Endodontics: A Systematic Review and Meta-Analysis.

Authors:  Mario Dioguardi; Diego Sovereto; Gaetano Illuzzi; Enrica Laneve; Bruna Raddato; Claudia Arena; Vito Carlo Alberto Caponio; Giorgia Apollonia Caloro; Khrystyna Zhurakivska; Giuseppe Troiano; Lorenzo Lo Muzio
Journal:  Int J Dent       Date:  2020-02-08
  10 in total