Literature DB >> 15273636

Current challenges and concepts in the preparation of root canal systems: a review.

Ove A Peters1.   

Abstract

Nickel-titanium rotary instruments are important adjuncts in endodontic therapy. This review attempts to identify factors that influence shaping outcomes with these files, such as preoperative root-canal anatomy and instrument tip design. Other, less significant factors include operator experience, rotational speed, and specific instrument sequence. Implications of various working length definitions and desired apical widths are correlated with clinical results. Despite the existence of one ever-present risk factor, dental anatomy, shaping outcomes with nickel-titanium rotary instruments are mostly predictable. Current evidence indicates that wider apical preparations are feasible. Nickel-titanium rotary instruments require a preclinical training period to minimize separation risks and should be used to case-related working lengths and apical widths. However, and despite superior in vitro results, randomized, clinical trials are required to evaluate outcomes when using nickel-titanium instruments.

Mesh:

Substances:

Year:  2004        PMID: 15273636     DOI: 10.1097/01.don.0000129039.59003.9d

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  223 in total

Review 1.  Impact of nickel-titanium instrumentation of the root canal on clinical outcomes: a focused review.

Authors:  Edgar Schäfer; Sebastian Bürklein
Journal:  Odontology       Date:  2012-04-22       Impact factor: 2.634

2.  Canal and isthmus debridement efficacies of two irrigant agitation techniques in a closed system.

Authors:  L Susin; Y Liu; J C Yoon; J M Parente; R J Loushine; D Ricucci; T Bryan; R N Weller; D H Pashley; F R Tay
Journal:  Int Endod J       Date:  2010-08-19       Impact factor: 5.264

3.  Comparison of Penetration of Irrigant Activated by Traditional Methods with A Novel Technique.

Authors:  Pavan Kumar Kanumuru; Sujatha Gopal Sooraparaju; Karthik Roy Konda; Surya Kumari Nujella; Bala Kasi Reddy; Siva Ram Penigalapati
Journal:  J Clin Diagn Res       Date:  2015-11-01

4.  ProTaper and WaveOne systems three-dimensional comparison of device parameters after the shaping technique. A micro-CT study on simulated root canals.

Authors:  Mario Dioguardi; Giuseppe Troiano; Luigi Laino; Lucio Lo Russo; Giovanni Giannatempo; Floriana Lauritano; Marco Cicciù; Lorenzo Lo Muzio
Journal:  Int J Clin Exp Med       Date:  2015-10-15

5.  Shaping ability of two nickel-titanium instruments activated by continuous rotation or adaptive motion: a micro-computed tomography study.

Authors:  E Pedullà; G Plotino; N M Grande; G Avarotti; G Gambarini; E Rapisarda; F Mannocci
Journal:  Clin Oral Investig       Date:  2016-02-15       Impact factor: 3.573

6.  Comparative Evaluation of Antimicrobial Activity of QMiX, 2.5% Sodium Hypochlorite, 2% Chlorhexidine, Guava Leaf Extract and Aloevera Extract Against Enterococcus faecalis and Candida albicans - An in-vitro Study.

Authors:  Jerin Jose; Shoba Krishnamma; Faizal Peedikayil; Shibu Aman; Nithya Tomy; Jithin Pulickal Mariodan
Journal:  J Clin Diagn Res       Date:  2016-05-01

7.  A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals.

Authors:  Young-Sil Yoo; Yong-Bum Cho
Journal:  Restor Dent Endod       Date:  2012-11-21

8.  Influence of CBCT parameters on the output of an automatic edge-detection-based endodontic segmentation.

Authors:  J Michetti; M Georgelin-Gurgel; J-P Mallet; F Diemer; K Boulanouar
Journal:  Dentomaxillofac Radiol       Date:  2015-06-02       Impact factor: 2.419

9.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

10.  Technical quality of a matching-taper single-cone filling technique following rotary instrumentation compared with lateral compaction after manual preparation: a retrospective study.

Authors:  R Krug; G Krastl; M Jahreis
Journal:  Clin Oral Investig       Date:  2016-08-13       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.