Canal shaping with WaveOne reciprocating files: influence of operator experience on instrument breakage and canal preparation time.

Luigi Generali1, Elena Righi, Maria Vittoria Todesca, Ugo Consolo.   

Abstract

The aim of this study was to determine the fracture incidence of WaveOne Primary reciprocating files and the time required for shaping of curved canals based on the experience of the operator. A total of 109 mesiobuccal canals of permanent molars extracted with an angle of curvature of >25°-45° according to Schneider were randomly assigned to four groups. An experienced operator (endodontist) and an inexperienced operator (student) each shaped one of two groups: one with the instrument WaveOne Primary to WL and the other after creation of a glide path with PathFile 1, 2 and 3 at the WL. Any fractures or visible deformations of the instruments during the shaping phase and the effective time required to prepare the canals for each instrument were recorded. No visible deformation or fracture was observed. The experienced operator tended to finish their shape faster than the inexperienced operator regardless of the technique applied. For the inexperienced operator, the usage time with only WaveOne Primary was significantly lower when the canals were preliminarily instrumented with the PathFile than when these instruments were not used (average time, 22.03 vs. 36.22 s, respectively; p < 0.001). The experience of the operator did not influence fracture of the WaveOne Primary instruments. The time required to prepare the canals was instead inversely proportional to the experience of the operator. However, the creation of a glide path with PathFile instruments reduced the time required by the inexperienced operator to prepare the canal.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23813221     DOI: 10.1007/s10266-013-0118-1

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  37 in total

1.  Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files.

Authors:  G M Yared; F E Bou Dagher; P Machtou; G K Kulkarni
Journal:  Int Endod J       Date:  2002-01       Impact factor: 5.264

2.  Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: value of the safety quotient.

Authors:  J Y Blum; P Machtou; C Ruddle; J P Micallef
Journal:  J Endod       Date:  2003-09       Impact factor: 4.171

3.  A comparison of cyclic fatigue resistance in reciprocating and rotary nickel-titanium instruments.

Authors:  Jeffrey Wan; Brian J Rasimick; Barry L Musikant; Allan S Deutsch
Journal:  Aust Endod J       Date:  2010-05-11       Impact factor: 1.659

4.  Resistance to flexural fatigue of Reciproc R25 files under continuous rotation and reciprocating movement.

Authors:  Giulio Gavini; Celso Luiz Caldeira; Eduardo Akisue; George Táccio de Miranda Candeiro; Dirce Akemi Sacaguti Kawakami
Journal:  J Endod       Date:  2012-01-24       Impact factor: 4.171

5.  Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals.

Authors:  Sung-Yeop You; Kwang-Shik Bae; Seung-Ho Baek; Kee-Yeon Kum; Won-Jun Shon; Woocheol Lee
Journal:  J Endod       Date:  2010-12       Impact factor: 4.171

6.  Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals.

Authors:  Elio Berutti; Giuseppe Cantatore; Arnaldo Castellucci; Giorgio Chiandussi; Francesco Pera; Giuseppe Migliaretti; Damiano Pasqualini
Journal:  J Endod       Date:  2009-03       Impact factor: 4.171

7.  Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

Authors:  Sebastian Bürklein; Edgar Schäfer
Journal:  J Endod       Date:  2012-04-06       Impact factor: 4.171

8.  A retrospective study of endodontic treatment outcome between nickel-titanium rotary and stainless steel hand filing techniques.

Authors:  Gary S P Cheung; Christopher S Y Liu
Journal:  J Endod       Date:  2009-07       Impact factor: 4.171

9.  The "balanced force" concept for instrumentation of curved canals.

Authors:  J B Roane; C L Sabala; M G Duncanson
Journal:  J Endod       Date:  1985-05       Impact factor: 4.171

10.  An in vitro comparison of torsional stress and cyclic fatigue resistance of ProFile GT and ProFile GT Series X rotary nickel-titanium files.

Authors:  Thomas R Kramkowski; James Bahcall
Journal:  J Endod       Date:  2009-03       Impact factor: 4.171

View more
  6 in total

1.  Double dye technique and fluid filtration test to evaluate early sealing ability of an endodontic sealer.

Authors:  Luigi Generali; C Prati; C Pirani; F Cavani; M R Gatto; M G Gandolfi
Journal:  Clin Oral Investig       Date:  2016-06-14       Impact factor: 3.573

2.  Simulated root canals preparation time, comparing ProTaper Next and WaveOne Gold systems, performed by an undergraduate student.

Authors:  Inês Conceição; Inês Ferreira; Ana-Cristina Braga; Irene Pina-Vaz
Journal:  J Clin Exp Dent       Date:  2020-08-01

3.  Preference of undergraduate students after first experience on nickel-titanium endodontic instruments.

Authors:  Sang Won Kwak; Gary Shun-Pan Cheung; Jung-Hong Ha; Sung Kyo Kim; Hyojin Lee; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2016-06-23

4.  Influence of Operator's Experience on the Shaping Ability of Protaper Universal and Waveone Systems: A Comparative Study on Simulated Root Canals.

Authors:  Giuseppe Troiano; Mario Dioguardi; Armando Cocco; Giovanni Giannatempo; Luigi Laino; Domenico Ciavarella; Elio Berutti; Lorenzo Lo Muzio
Journal:  Open Dent J       Date:  2016-10-07

5.  Evaluation of canal transportation after preparation with Reciproc single-file systems with or without glide path files.

Authors:  Ugur Aydin; Emrah Karataslioglu
Journal:  J Conserv Dent       Date:  2017 Jul-Aug

6.  Reciproc Endodontic File Surface Defects After Single Use: An SEM Analysis.

Authors:  Mohammed Howait
Journal:  J Int Soc Prev Community Dent       Date:  2021-01-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.