Literature DB >> 27716640

A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties.

Li Tao1, Henry M Daghighian, Craig S Levin.   

Abstract

Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the other hand, modulation mechanisms of the optical properties of a material exploited in the optical telecommunications industry can be orders of magnitude faster. In this paper we borrow from the concept of optics pump-probe measurement to for the first time study whether ionizing radiation can produce modulations of optical properties, which can be utilized as a novel method for radiation detection. We show that a refractive index modulation of approximately [Formula: see text] is induced by interactions in a cadmium telluride (CdTe) crystal from a 511 keV photon source. Furthermore, using additional radionuclide sources, we show that the amplitude of the optical modulation signal varies linearly with both the detected event rate and average photon energy of the radiation source.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27716640      PMCID: PMC5117889          DOI: 10.1088/0031-9155/61/21/7600

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  Investigation of time-of-flight benefit for fully 3-D PET.

Authors:  Suleman Surti; Joel S Karp; Lucretiu M Popescu; Margaret E Daube-Witherspoon; Matthew Werner
Journal:  IEEE Trans Med Imaging       Date:  2006-05       Impact factor: 10.048

2.  Label-free, single-molecule detection with optical microcavities.

Authors:  Andrea M Armani; Rajan P Kulkarni; Scott E Fraser; Richard C Flagan; Kerry J Vahala
Journal:  Science       Date:  2007-07-05       Impact factor: 47.728

Review 3.  State of the art and challenges of time-of-flight PET.

Authors:  Maurizio Conti
Journal:  Phys Med       Date:  2008-12-19       Impact factor: 2.685

4.  Label-free detection with high-Q microcavities: a review of biosensing mechanisms for integrated devices.

Authors:  Frank Vollmer; Lan Yang
Journal:  Nanophotonics       Date:  2012-12-06       Impact factor: 8.449

5.  Investigating the temporal resolution limits of scintillation detection from pixellated elements: comparison between experiment and simulation.

Authors:  V Ch Spanoudaki; C S Levin
Journal:  Phys Med Biol       Date:  2011-01-14       Impact factor: 3.609

6.  Analytical calculation of the lower bound on timing resolution for PET scintillation detectors comprising high-aspect-ratio crystal elements.

Authors:  Joshua W Cates; Ruud Vinke; Craig S Levin
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

7.  Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

Authors:  C S Levin; E J Hoffman
Journal:  Phys Med Biol       Date:  1999-03       Impact factor: 3.609

8.  Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.

Authors:  Y Gu; J L Matteson; R T Skelton; A C Deal; E A Stephan; F Duttweiler; T M Gasaway; C S Levin
Journal:  Phys Med Biol       Date:  2011-02-18       Impact factor: 3.609

9.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

10.  Advances in coincidence time resolution for PET.

Authors:  Joshua W Cates; Craig S Levin
Journal:  Phys Med Biol       Date:  2016-02-25       Impact factor: 3.609

View more
  5 in total

1.  Study of material properties important for an optical property modulation-based radiation detection method for positron emission tomography.

Authors:  Li Tao; Henry M Daghighian; Craig S Levin
Journal:  J Med Imaging (Bellingham)       Date:  2017-02-01

2.  Effect of CZT system characteristics on Compton scatter event recovery.

Authors:  Sheng Yang; Mohan Li; Michael Reed; James Hugg; Henry Chen; Shiva Abbaszadeh
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-05-06

3.  Two-crossed-polarizers based optical property modulation method for ionizing radiation detection for positron emission tomography.

Authors:  Yuli Wang; Yingjie Li; Fei Yi; Junyu Li; Siwei Xie; Qiyu Peng; Jianfeng Xu
Journal:  Phys Med Biol       Date:  2019-07-05       Impact factor: 3.609

4.  Evaluation of a clinical TOF-PET detector design that achieves ⩽100 ps coincidence time resolution.

Authors:  Joshua W Cates; Craig S Levin
Journal:  Phys Med Biol       Date:  2018-06-07       Impact factor: 3.609

5.  Further investigations of a radiation detector based on ionization-induced modulation of optical polarization.

Authors:  Yuli Wang; Li Tao; Shiva Abbaszadeh; Craig Levin
Journal:  Phys Med Biol       Date:  2021-02-20       Impact factor: 3.609

  5 in total