Literature DB >> 28180132

Study of material properties important for an optical property modulation-based radiation detection method for positron emission tomography.

Li Tao1, Henry M Daghighian2, Craig S Levin3.   

Abstract

We compare the performance of two detector materials, cadmium telluride (CdTe) and bismuth silicon oxide (BSO), for optical property modulation-based radiation detection method for positron emission tomography (PET), which is a potential new direction to dramatically improve the annihilation photon pair coincidence time resolution. We have shown that the induced current flow in the detector crystal resulting from ionizing radiation determines the strength of optical modulation signal. A larger resistivity is favorable for reducing the dark current (noise) in the detector crystal, and thus the higher resistivity BSO crystal has a lower (50% lower on average) noise level than CdTe. The CdTe and BSO crystals can achieve the same sensitivity under laser diode illumination at the same crystal bias voltage condition while the BSO crystal is not as sensitive to 511-keV photons as the CdTe crystal under the same crystal bias voltage. The amplitude of the modulation signal induced by 511-keV photons in BSO crystal is around 30% of that induced in CdTe crystal under the same bias condition. In addition, we have found that the optical modulation strength increases linearly with crystal bias voltage before saturation. The modulation signal with CdTe tends to saturate at bias voltages higher than 1500 V due to its lower resistivity (thus larger dark current) while the modulation signal strength with BSO still increases after 3500 V. Further increasing the bias voltage for BSO could potentially further enhance the modulation strength and thus, the sensitivity.

Entities:  

Keywords:  bismuth silicon oxide; cadmium telluride; fast timing; optical property modulation; positron emission tomography; time-of-flight

Year:  2017        PMID: 28180132      PMCID: PMC5286320          DOI: 10.1117/1.JMI.4.1.011010

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  11 in total

Review 1.  Molecular imaging of cancer with positron emission tomography.

Authors:  Sanjiv Sam Gambhir
Journal:  Nat Rev Cancer       Date:  2002-09       Impact factor: 60.716

Review 2.  Positron-emission tomography and assessment of cancer therapy.

Authors:  Malik E Juweid; Bruce D Cheson
Journal:  N Engl J Med       Date:  2006-02-02       Impact factor: 91.245

3.  Investigation of time-of-flight benefit for fully 3-D PET.

Authors:  Suleman Surti; Joel S Karp; Lucretiu M Popescu; Margaret E Daube-Witherspoon; Matthew Werner
Journal:  IEEE Trans Med Imaging       Date:  2006-05       Impact factor: 10.048

4.  Label-free, single-molecule detection with optical microcavities.

Authors:  Andrea M Armani; Rajan P Kulkarni; Scott E Fraser; Richard C Flagan; Kerry J Vahala
Journal:  Science       Date:  2007-07-05       Impact factor: 47.728

5.  Benefit of time-of-flight in PET: experimental and clinical results.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

6.  Analytical calculation of the lower bound on timing resolution for PET scintillation detectors comprising high-aspect-ratio crystal elements.

Authors:  Joshua W Cates; Ruud Vinke; Craig S Levin
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

7.  Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

Authors:  C S Levin; E J Hoffman
Journal:  Phys Med Biol       Date:  1999-03       Impact factor: 3.609

8.  A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties.

Authors:  Li Tao; Henry M Daghighian; Craig S Levin
Journal:  Phys Med Biol       Date:  2016-10-07       Impact factor: 3.609

9.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

10.  Fast, accurate and shift-varying line projections for iterative reconstruction using the GPU.

Authors:  Guillem Pratx; Garry Chinn; Peter D Olcott; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2009-03       Impact factor: 10.048

View more
  3 in total

1.  Two-crossed-polarizers based optical property modulation method for ionizing radiation detection for positron emission tomography.

Authors:  Yuli Wang; Yingjie Li; Fei Yi; Junyu Li; Siwei Xie; Qiyu Peng; Jianfeng Xu
Journal:  Phys Med Biol       Date:  2019-07-05       Impact factor: 3.609

2.  Evaluation of a clinical TOF-PET detector design that achieves ⩽100 ps coincidence time resolution.

Authors:  Joshua W Cates; Craig S Levin
Journal:  Phys Med Biol       Date:  2018-06-07       Impact factor: 3.609

3.  Further investigations of a radiation detector based on ionization-induced modulation of optical polarization.

Authors:  Yuli Wang; Li Tao; Shiva Abbaszadeh; Craig Levin
Journal:  Phys Med Biol       Date:  2021-02-20       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.