Literature DB >> 33498027

Further investigations of a radiation detector based on ionization-induced modulation of optical polarization.

Yuli Wang1, Li Tao2, Shiva Abbaszadeh1, Craig Levin2.   

Abstract

Optical property modulation induced by ionizing radiation is a promising approach for ultra-fast, lower time jitter detection of photon arrival time. If successful, this method can be utilized in time-of-flight positron emission tomography to achieve a coincidence time resolution approaching 10 ps. In this work, the optical property modulation based method is further developed with focus on a detection setup based on two crossed polarizers. Previous work demonstrated that such an optical setup could be utilized in radiation detection, though its detection sensitivity needed improvement. This work investigates the angle between polarizers and electric field distribution within the detection crystal to understand and improve the detection sensitivity of an optical polarization modulation based method. For this work, cadmium telluride (CdTe) was studied as the detector crystal . The 'magic' angle (i.e. optimal working angle) of the two crossed polarizers based optical setup with CdTe were explored theoretically and experimentally. The experimental results show that the detection sensitivity could be improved by around 10% by determining the appropriate 'magic' angle. We then studied the dependence of detection sensitivity on electric field distribution as well as on the bias voltage across the detector crystal using CdTe crystals. The experimental results show that a smaller electrode on the detector crystal, or a more concentrated electric field distribution could improve detection sensitivity. For CdTe, a detector crystal sample with 2.5 mm × 2.5 mm square electrode has twice the detection sensitivity of a detector crystal with 5 mm × 5 mm square electrode. Increasing the bias voltage before saturation for CdTe could further enhance the modulation strength and thus, the sensitivity. Our investigations demonstrated that by determining the proper working angle of polarizers and bias electrical distribution to the detector, we could improve the sensitivity of the proposed optical setup.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33498027      PMCID: PMC8032502          DOI: 10.1088/1361-6560/abe027

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Electro-optic coefficient spectrum of cadmium telluride.

Authors:  D B Chenault; R A Chipman; S Y Lu
Journal:  Appl Opt       Date:  1994-11-01       Impact factor: 1.980

2.  Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca.

Authors:  Mythra Varun Nemallapudi; Stefan Gundacker; Paul Lecoq; Etiennette Auffray; Alessandro Ferri; Alberto Gola; Claudio Piemonte
Journal:  Phys Med Biol       Date:  2015-05-28       Impact factor: 3.609

3.  Study of material properties important for an optical property modulation-based radiation detection method for positron emission tomography.

Authors:  Li Tao; Henry M Daghighian; Craig S Levin
Journal:  J Med Imaging (Bellingham)       Date:  2017-02-01

4.  Measurement of intrinsic rise times for various L(Y)SO and LuAG scintillators with a general study of prompt photons to achieve 10 ps in TOF-PET.

Authors:  Stefan Gundacker; Etiennette Auffray; Kristof Pauwels; Paul Lecoq
Journal:  Phys Med Biol       Date:  2016-03-16       Impact factor: 3.609

5.  Evaluation of a clinical TOF-PET detector design that achieves ⩽100 ps coincidence time resolution.

Authors:  Joshua W Cates; Craig S Levin
Journal:  Phys Med Biol       Date:  2018-06-07       Impact factor: 3.609

6.  Cerenkov radiation energy transfer (CRET) imaging: a novel method for optical imaging of PET isotopes in biological systems.

Authors:  Robin S Dothager; Reece J Goiffon; Erin Jackson; Scott Harpstrite; David Piwnica-Worms
Journal:  PLoS One       Date:  2010-10-11       Impact factor: 3.240

7.  Influence of ferroelectric polarization on the equilibrium stoichiometry of lithium niobate (0001) surfaces.

Authors:  Sergey V Levchenko; Andrew M Rappe
Journal:  Phys Rev Lett       Date:  2008-06-23       Impact factor: 9.161

8.  Advances in coincidence time resolution for PET.

Authors:  Joshua W Cates; Craig S Levin
Journal:  Phys Med Biol       Date:  2016-02-25       Impact factor: 3.609

9.  Simulation studies to understand sensitivity and timing characteristics of an optical property modulation-based radiation detection concept for PET.

Authors:  Li Tao; Diana Jeong; Jinghui Wang; Zander Adams; Peter Bryan; Craig S Levin
Journal:  Phys Med Biol       Date:  2020-11-03       Impact factor: 3.609

10.  THE VISUAL DISCRIMINATION OF INTENSITY AND THE WEBER-FECHNER LAW.

Authors:  S Hecht
Journal:  J Gen Physiol       Date:  1924-11-20       Impact factor: 4.086

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.