Effect of CZT system characteristics on Compton scatter event recovery.

Sheng Yang1, Mohan Li1, Michael Reed2, James Hugg2, Henry Chen2, Shiva Abbaszadeh1.   

Abstract

Improving 511 keV photon detection sensitivity is a common goal for positron emission tomography system designers. One attractive approach to increase sensitivity is recovering events that are normally rejected. The kinematics of Compton scattering can be used to recover the line of response through direction difference angle (DDA). The uncertainty of DDA is determined by the energy and spatial resolution of a system. In this work, we evaluated the performance of small animal CZT-based positron emission tomography systems with energy resolution of 1%, 4%, and 6% and different spatial resolution based on prior work for guiding new design efforts. Designs with energy resolution limited by counting statistics and by electronic noise were considered. The influence of modifying the conventional energy window and uncertainty of DDA was investigated. For a system with 4% energy resolution and limited by electronic noise, the figure of merit of noise equivalent count increases by 65% as the lower energy bound increases from 471 keV to 493 keV. If the system-wide energy resolution becomes worse than 4% of the full width half maximum at 511 keV, going to a pixel size finer than 1 mm has very limited effect in reducing total angular uncertainty. For a system with 1% energy resolution, as the spatial resolution improves from 1 mm to 0.5 mm, the contrast-to-noise ratio increases by 9%.

Entities:  

Keywords:  CZT; Compton Recovery; PET; Sensitivity

Year:  2019        PMID: 31922083      PMCID: PMC6952068          DOI: 10.1109/TRPMS.2019.2915054

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  19 in total

1.  Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA.

Authors:  Jing-Yu Cui; Guillem Pratx; Sven Prevrhal; Craig S Levin
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Preliminary evaluation of a novel energy-resolved photon-counting gamma ray detector.

Authors:  L-J Meng; J W Tan; K Spartiotis; T Schulman
Journal:  Nucl Instrum Methods Phys Res A       Date:  2009-03-19       Impact factor: 1.455

3.  A novel, SiPM-array-based, monolithic scintillator detector for PET.

Authors:  Dennis R Schaart; Herman T van Dam; Stefan Seifert; Ruud Vinke; Peter Dendooven; Herbert Löhner; Freek J Beekman
Journal:  Phys Med Biol       Date:  2009-05-15       Impact factor: 3.609

4.  Spatial resolution and sensitivity of the Inveon small-animal PET scanner.

Authors:  Eric P Visser; Jonathan A Disselhorst; Maarten Brom; Peter Laverman; Martin Gotthardt; Wim J G Oyen; Otto C Boerman
Journal:  J Nucl Med       Date:  2009-01       Impact factor: 10.057

5.  Sensitivity recovery for the AX-PET prototype using inter-crystal scattering events.

Authors:  John E Gillam; Paola Solevi; Josep F Oliver; Chiara Casella; Matthieu Heller; Christian Joram; Magdalena Rafecas
Journal:  Phys Med Biol       Date:  2014-07-03       Impact factor: 3.609

6.  Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner.

Authors:  Yuchuan Wang; Jurgen Seidel; Benjamin M W Tsui; Juan J Vaquero; Martin G Pomper
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

7.  Impact of high energy resolution detectors on the performance of a PET system dedicated to breast cancer imaging.

Authors:  Craig S Levin; Angela M K Foudray; Frezghi Habte
Journal:  Phys Med       Date:  2006       Impact factor: 2.685

8.  DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillators.

Authors:  Samuel España; Radoslaw Marcinkowski; Vincent Keereman; Stefaan Vandenberghe; Roel Van Holen
Journal:  Phys Med Biol       Date:  2014-06-03       Impact factor: 3.609

9.  Positioning true coincidences that undergo inter-and intra-crystal scatter for a sub-mm resolution cadmium zinc telluride-based PET system.

Authors:  Shiva Abbaszadeh; Garry Chinn; Craig S Levin
Journal:  Phys Med Biol       Date:  2018-01-09       Impact factor: 3.609

10.  Characterization of a sub-assembly of 3D position sensitive cadmium zinc telluride detectors and electronics from a sub-millimeter resolution PET system.

Authors:  Shiva Abbaszadeh; Yi Gu; Paul D Reynolds; Craig S Levin
Journal:  Phys Med Biol       Date:  2016-08-23       Impact factor: 3.609

View more
  1 in total

1.  Design study of a dedicated head and neck cancer PET system.

Authors:  Mohan Li; Brett Yockey; Shiva Abbaszadeh
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-01-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.