A rapid and robust gradient measurement technique using dynamic single-point imaging.

Hyungseok Jang1,2, Alan B McMillan1.   

Abstract

PURPOSE: We propose a new gradient measurement technique based on dynamic single-point imaging (SPI), which allows simple, rapid, and robust measurement of k-space trajectory.
METHODS: To enable gradient measurement, we utilize the variable field-of-view (FOV) property of dynamic SPI, which is dependent on gradient shape. First, one-dimensional (1D) dynamic SPI data are acquired from a targeted gradient axis, and then relative FOV scaling factors between 1D images or k-spaces at varying encoding times are found. These relative scaling factors are the relative k-space position that can be used for image reconstruction. The gradient measurement technique also can be used to estimate the gradient impulse response function for reproducible gradient estimation as a linear time invariant system.
RESULTS: The proposed measurement technique was used to improve reconstructed image quality in 3D ultrashort echo, 2D spiral, and multi-echo bipolar gradient-echo imaging. In multi-echo bipolar gradient-echo imaging, measurement of the k-space trajectory allowed the use of a ramp-sampled trajectory for improved acquisition speed (approximately 30%) and more accurate quantitative fat and water separation in a phantom.
CONCLUSION: The proposed dynamic SPI-based method allows fast k-space trajectory measurement with a simple implementation and no additional hardware for improved image quality. Magn Reson Med 78:950-962, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  GIRF; calibration; eddy current; gradient; k-space trajectory; single-point imaging

Mesh:

Year:  2016        PMID: 27699867      PMCID: PMC5378680          DOI: 10.1002/mrm.26481

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  44 in total

1.  Reconstructing MR images from undersampled data: data-weighting considerations.

Authors:  J G Pipe
Journal:  Magn Reson Med       Date:  2000-06       Impact factor: 4.668

2.  Sampling density compensation in MRI: rationale and an iterative numerical solution.

Authors:  J G Pipe; P Menon
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

3.  High-resolution ZTE imaging of human teeth.

Authors:  Markus Weiger; Klaas P Pruessmann; Anna-Katinka Bracher; Sascha Köhler; Volker Lehmann; Uwe Wolfram; Franciszek Hennel; Volker Rasche
Journal:  NMR Biomed       Date:  2012-01-31       Impact factor: 4.044

4.  Gradient system characterization by impulse response measurements with a dynamic field camera.

Authors:  Signe J Vannesjo; Maximilan Haeberlin; Lars Kasper; Matteo Pavan; Bertram J Wilm; Christoph Barmet; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2012-04-12       Impact factor: 4.668

5.  Robust spatially selective excitation using radiofrequency pulses adapted to the effective spatially encoding magnetic fields.

Authors:  Johannes T Schneider; Martin Haas; Wolfgang Ruhm; Jürgen Hennig; Peter Ullmann
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

6.  Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging.

Authors:  Scott B Reeder; Angel R Pineda; Zhifei Wen; Ann Shimakawa; Huanzhou Yu; Jean H Brittain; Garry E Gold; Christopher H Beaulieu; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

7.  Analysis of the eddy-current induced artifacts and the temporal compensation in nuclear magnetic resonance imaging.

Authors:  C B Ahn; Z H Cho
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

8.  Field camera measurements of gradient and shim impulse responses using frequency sweeps.

Authors:  S Johanna Vannesjo; Benjamin E Dietrich; Matteo Pavan; David O Brunner; Bertram J Wilm; Christoph Barmet; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2013-09-16       Impact factor: 4.668

9.  Pure phase encode magnetic field gradient monitor.

Authors:  Hui Han; Rodney P MacGregor; Bruce J Balcom
Journal:  J Magn Reson       Date:  2009-09-17       Impact factor: 2.229

10.  Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: optimization of corrections and quantitative characterization of magnet/gradient systems.

Authors:  C Boesch; R Gruetter; E Martin
Journal:  Magn Reson Med       Date:  1991-08       Impact factor: 4.668

View more
  5 in total

Review 1.  Magnetic Resonance Imaging of Hard Tissues and Hard Tissue Engineered Bio-substitutes.

Authors:  Simone Mastrogiacomo; Weiqiang Dou; John A Jansen; X Frank Walboomers
Journal:  Mol Imaging Biol       Date:  2019-12       Impact factor: 3.488

2.  Characterization of hardware-related spatial distortions for IR-PETRA pulse sequence using a brain specific phantom.

Authors:  Sima Ahmadian; Iraj Jabbari; Seyed Mehdi Bagherimofidi; Hamidreza Saligheh Rad
Journal:  MAGMA       Date:  2020-07-06       Impact factor: 2.310

3.  Fat suppression for ultrashort echo time imaging using a single-point Dixon method.

Authors:  Hyungseok Jang; Michael Carl; Yajun Ma; Saeed Jerban; Tan Guo; Wei Zhao; Eric Y Chang; Jiang Du
Journal:  NMR Biomed       Date:  2019-02-15       Impact factor: 4.044

4.  Rapid single scan ramped hybrid-encoding for bicomponent T2* mapping in a human knee joint: A feasibility study.

Authors:  Hyungseok Jang; Alan B McMillan; Yajun Ma; Saeed Jerban; Eric Y Chang; Jiang Du; Richard Kijowski
Journal:  NMR Biomed       Date:  2020-08-05       Impact factor: 4.044

5.  Rapid dual-echo ramped hybrid encoding MR-based attenuation correction (dRHE-MRAC) for PET/MR.

Authors:  Hyungseok Jang; Fang Liu; Tyler Bradshaw; Alan B McMillan
Journal:  Magn Reson Med       Date:  2017-10-02       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.