Literature DB >> 10025627

Sampling density compensation in MRI: rationale and an iterative numerical solution.

J G Pipe1, P Menon.   

Abstract

Data collection of MRI which is sampled nonuniformly in k-space is often interpolated onto a Cartesian grid for fast reconstruction. The collected data must be properly weighted before interpolation, for accurate reconstruction. We propose a criterion for choosing the weighting function necessary to compensate for nonuniform sampling density. A numerical iterative method to find a weighting function that meets that criterion is also given. This method uses only the coordinates of the sampled data; unlike previous methods, it does not require knowledge of the trajectories and can easily handle trajectories that "cross" in k-space. Moreover, the method can handle sampling patterns that are undersampled in some regions of k-space and does not require a post-gridding density correction. Weighting functions for various data collection strategies are shown. Synthesized and collected in vivo data also illustrate aspects of this method.

Mesh:

Substances:

Year:  1999        PMID: 10025627     DOI: 10.1002/(sici)1522-2594(199901)41:1<179::aid-mrm25>3.0.co;2-v

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  96 in total

1.  Dynamic magnetic resonance imaging paragraph sign with radial scanning: a post-acquisition paragraph sign keyhole approach.

Authors:  R Lethmate; H Ratiney; F T A W Wajer; Y Crémillieux; D van Ormondt; D Graveron-Demilly
Journal:  MAGMA       Date:  2003-02       Impact factor: 2.310

2.  Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI.

Authors:  Ali Gholipour; Onur Afacan; Iman Aganj; Benoit Scherrer; Sanjay P Prabhu; Mustafa Sahin; Simon K Warfield
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

3.  NonCartesian MR image reconstruction with integrated gradient nonlinearity correction.

Authors:  Shengzhen Tao; Joshua D Trzasko; Yunhong Shu; John Huston; Kevin M Johnson; Paul T Weavers; Erin M Gray; Matt A Bernstein
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

4.  Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction.

Authors:  Jiayu Song; Yanhui Liu; Sally L Gewalt; Gary Cofer; G Allan Johnson; Qing Huo Liu
Journal:  IEEE Trans Biomed Eng       Date:  2009-01-23       Impact factor: 4.538

5.  Ramped hybrid encoding for improved ultrashort echo time imaging.

Authors:  Hyungseok Jang; Curtis N Wiens; Alan B McMillan
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

6.  Preclinical hyperpolarized 129 Xe MRI: ventilation and T2 * mapping in mouse lungs at 7 T using multi-echo flyback UTE.

Authors:  Peter J Niedbalski; Alexander S Cochran; Teckla G Akinyi; Robert P Thomen; Elizabeth M Fugate; Diana M Lindquist; Ronald G Pratt; Zackary I Cleveland
Journal:  NMR Biomed       Date:  2020-04-14       Impact factor: 4.044

7.  Accelerated whole-heart coronary MRA using motion-corrected sensitivity encoding with three-dimensional projection reconstruction.

Authors:  Jianing Pang; Behzad Sharif; Reza Arsanjani; Xiaoming Bi; Zhaoyang Fan; Qi Yang; Kuncheng Li; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

8.  Dynamic phosphocreatine imaging with unlocalized pH assessment of the human lower leg muscle following exercise at 3T.

Authors:  Oleksandr Khegai; Guillaume Madelin; Ryan Brown; Prodromos Parasoglou
Journal:  Magn Reson Med       Date:  2017-05-30       Impact factor: 4.668

9.  3D MRI of impaired hyperpolarized 129Xe uptake in a rat model of pulmonary fibrosis.

Authors:  Zackary I Cleveland; Rohan S Virgincar; Yi Qi; Scott H Robertson; Simone Degan; Bastiaan Driehuys
Journal:  NMR Biomed       Date:  2014-05-12       Impact factor: 4.044

10.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.